Hotel Gas Fire Tube Boiler

WNS5.6-1.0/115/70-Y 5.6 MW oil fired hotel fire tube boiler exported to Russia

WNS2-1.25-Y Gas Boiler exported to Turkey

Gas hotel fire tube boiler safe handling as the country increasingly stringent emission standards for air pollution, the country has already started work boilers from coal to gas, out of heavily polluting coal-fired boilers, gas boilers using clean fuels. In this regard, Kono Tips boiler, gas boiler process, the need to pay attention to some safety issues: 1. burner to keep the working environment clean and dry, burner cleaning and maintenance once per shift to the control circuit must not get wet, affected by high temperature. 2. Check the electrical installations, mainly: whether the damaged wire, jacket damage, without loosening the screws, the contact is good, the motor is running any abnormal sound. 3. During normal operation, the burner portion close to thermodynamic device (such as a flange connection part) will be very hot, to avoid burns. Do not place near flammable materials, so as not to cause a fire. 4. combustor during startup, if the burner is locked repeated alarm reasons should be identified, and then identify failures and excluded press the reset button (pressing the reset button must not exceed 10 seconds), continue to start. 5. After the total gas pipeline experienced a temporary power failure solenoid valve (steel tile shed) to stop gas supply will automatically shut down until the first call burner electric alarm device to send, then a small hammer solenoid valve with total on hand to pull, you must first send electricity to manually open solenoid valve, solenoid valve will be closed and vice versa total. 6. fireman not mess-tune the burner, abnormal promptly notify management personnel, approved by management and then make adjustments. 7. In the long-term shutdown state, to do maintenance work on the boiler equipment, for each transmission parts to clean, lubricate.

February 13, 2019, a food processing plant in Heilongjiang province, after the Spring Festival to resume production process, hotel fire tube boiler explosion accident occurred, killing two people were killed, to the masses lives and property of people come at a cost, resulting in adverse social impact .

To reduce boiler accident, maintain social stability and security personnel, Suihua City Market Authority to act quickly, on February 15 Kusakabe issued an emergency notice to deploy to carry out safety hazards investigation boilers within the city, the focus of the investigation after the Spring Festival recovery boiler operation baths and other crowded places in boilers, boiler timely elimination of security risks in the management and operation aspects of existence.

As of now, law enforcement officers deployed 116 times, check unit 52, checks the boiler 64 for five in the boiler there are security risks of Special Equipment Safety Supervision issued a letter of instruction, ordered to stop using, be put into use after the rectification qualified.

Horizontal 0.5 tons supervisory inspection-free amount of gas steam hotel fire tube boiler is how much? There are a lot of users call and ask when will the relationship between the amount of gas steam boilers are, of course, this problem is related to the user's operating costs, and all of us today about 0.5 tons of horizontal gas-free amount is how much steam boiler inspection supervisor . First to introduce my company developed its own supervisory inspection-free steam boiler, only about 110 degrees this steam boiler exhaust gas temperature, and ordinary steam boiler exhaust gas temperature as high as 250-350, saves considerable steam boiler if the index is to see its exhaust gas temperature, exhaust gas temperature is lower fuel burn more fully explained in the furnace, the more fuel is absorbed by the heat from the steam boiler, the more fuel-efficient, the company supervisory inspection-free horizontal 0.5 tons of steam per hour coal boiler is about 40-50 kg, Common horizontal 0.5 tons coal consumption is about 70-80 kg.