9852 120 tph steam boiler natural gas

The main reason gas 9852 120 tph steam boiler produces smoke which fuel gas steam boiler main cause of smoke. A fuel gas steam boiler: oil, gas oil quality is not good when the gas contains more water, reduce the heat value of the fuel, while producing steam, the furnace temperature tends to decrease, making it difficult to burn, easy to produce smoke. Water and more oil, mainly when unloading rain water into the oil during heating the oil in water vapor penetration. When the oil contains impurities, the impurities unburned produce fine coke, the coke into fine smoke, dust becomes large, and the formation of soot. Impurities contained in the oil and gas, but also affect the pure oil and pure combustion gas generated soot. Oil impurities, mainly due to inappropriate choice of filters or filter difference impurity removal effect. Second, the failure of the fuel atomizing nozzle member main burner fuel oil atomizing nozzle. Atomizing oil burner nozzle fails, affecting the quality of the atomization, easy to poor combustion. 1, the adhesiveness between the bonding surface of the oil and the consequences of failure oil atomizers swirl atomizers and the splitter plate well, leakage will occur, atomized large oil particles, increasing the amount of fuel injection and the like. In this case serious deterioration of the quality of the combustion, the oil droplets have landed on the water wall, stacking up oil coke, partially unburned black smoke into droplets. The tangential swirl chip groove clogging mist causes uneven density distribution in the dense side of the oil mist, combustion air be insufficient. In the more dilute side of the oil mist, combustion air causes severe local excess. Mixed with oil, wind conditions deteriorated significantly, combustion conditions deteriorate, resulting in black smoke. 2, spray atomization slice failure and the consequences of failure to clogging and wear. Nozzle clogging, resulting in blockage of the fuel injection quantity is not glib increase, oil particle size thicker, the effect of fuel poor and black smoke. Wear injection port, a large hole diameter, increasing the amount of fuel injection, increasing the particle size of oil affect combustion efficiency, produce black smoke. The use of artificial gas burner, naphthalene and tar and other impurities will block the nozzles, the influence of gas distribution, resulting in black smoke. Should therefore be cleaned regularly, or clogging of the selected burner. 3, the partition partitioning poor poor, insufficient supply of air into and excess. The amount of air can not meet the requirements of the fuel combustion, so that combustion of fuel can not be sufficiently black smoke. The amount of air, will result in lower combustion temperature, black smoke and fuel difficult to burn. 4, the furnace temperature is too low when starting the furnace, fuel oil steam boiler furnace temperature is too low due to easy black smoke. 5, the furnace hearth product oil is sometimes caused by internal combustion nozzle oil accumulated inside the chamber, the oil reservoir coke black smoke at high temperature. Causes dripping of fuel combustion nozzle: ① The drip just work, just at the operating pressure is too low, the oil will flow from the nozzle, instead of the discharge. The reason for low oil pressure is a solenoid valve, the valve is clogged filter or the like or failure caused by contamination. ② In the dripping process work, probably because the relative position of burner nozzle mounting head too far, improper ignition electrode position, the oil into the atomizer, the nozzle holder is mounted is not tight, nozzle dirty, low oil pressure caused. ③ When the dripping stopped, because the line between the pump and the air nozzle, electromagnetic valve or a hydraulic valve or dirty failure. 6, the furnace flue purged countless consequences when the furnace flue remnants of oil and gas, when gas purging endless, high temperatures encountered in the explosion and black smoke. 7, the furnace smoke, sparks, the furnace pressure is too ①; ② inappropriate choice of the burner, the burner flame is too long or too much power; ③ improper combustion ratio, there are more to produce products of incomplete combustion; ④ atomization quality is not good nozzle or improper installation location, or affect the combustion flame into the furnace off port; ⑤ flue is blocked, poor smoke; ⑥ a secondary air mismatches; irrational ⑦ furnace structure; ⑧ oil spray angle is selected from with improper.

Fangkuai Boiler is a clean-up boiler equipment based on various excellent scientific and technological advancements, focusing on product development, manufacturing, and manufacturing that are more efficient, environmentally friendly, and energy saving, and meet the basic national conditions of environmental protection in China. In order to promote the rapid development of the heating furnace manufacturing industry, people-oriented, consider the specific requirements of customers in the manufacturing industry for heating furnaces in various industries.

By burning and the like during combustion of the fuel to ensure complete combustion 9852 120 tph steam boilers boiling water volume electrical means at night using low power boiler water boiled and stored in the insulating state. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. Thus, a low-boiling nitrogen Burner electric device is an important fuel for industrial boilers and the gas boiler, which provides power to a small power people, and daytime combustion complete combustion of the fuel. Fengtai Electric boiling water into the boiler heat recovery boiler electric boiling water, boiling water boiler and continuous electrical breakdown electric boiling water boiler. 3. The principle of the burner is to shade a portion of the fuel burned too small, a small portion of the fuel burned too light, but the high air volume 360 ​​remains constant. Since the two partial combustion deviated from a stoichiometric ratio, the NOx is low, also called the combustion or stoichiometric combustion variation. 4. The principle of segmented flame burner flame is divided into several identical small flame, because the small flame having a large heat dissipating area and a smaller flame temperature!

Laundry hotel special reference to the current selection of 9852 120 tph steam boilers Hotels generally use the hot water boiler for heating and sanitary hot water, kitchen utensils gas can be directly used, but still need to supply steam laundry room, laundry room steam supply pressure to be 0.4-0.6 MPa, generally an amount of steam in the hotel laundry 0.5 ~ 2.0T / H, steam day with about 3 to 10 tons. Under the premise of the city's coal-fired boilers can not be used, the choice of energy sources natural gas, diesel, liquefied petroleum gas, electricity, in what exactly it is more appropriate? First use to compare the cost of various energy sources, according to Henan hotel energy prices, natural gas is 3.0 yuan / Nm3, diesel 9.0 yuan / kg, liquefied petroleum gas 15 yuan / Nm3, the price of 1 yuan / kwh. Compare 1 ton of steam produced by a variety of energy costs as follows: Energy Category Energy calorific value of natural gas in energy costs per ton of steam 8600kcal / Nm380m33.0 yuan / Nm3240 yuan / ton diesel 10400kcal / kg66kg9 energy consumption per ton of steam energy prices. 0 yuan / kg594 yuan / ton liquefied 22000kcal / Nm331m315 yuan / Nm3465 yuan / ton electric 1kwh700kwh1 yuan / kwh700 yuan / ton Note: energy consumption efficiency estimated by conventional steam boiler; Nm3 refers to the standard state volume of gas M3; calculated from the above analysis, the use of natural gas per ton of steam lowest cost, most economical operation, electrically heated steam up costs. Gas steam boiler typically 2 to 3 sets of selection, single nominal amount of evaporation 0.5T / H ~ 1.5T / H. Gas-fired steam boiler boiler range belong to the state regulators, the need to build a separate boiler room, not like pressure hot water boiler as the main building or in the basement, while the city hotels are often difficult to have a location to build a separate boiler room. In recent years, there is a new type of gas steam boiler, the water capacity is small (less than 30L), a single evaporation accessible 1T / H, do not belong to the state boiler steam boiler regulation range, can be in the basement, a good solution to the conventional steam boiler no suitable location problems.