Distributor 4t coal steam boiler High Efficiency Turkey

Comparison of coal-fired distributor 4t coal steam boiler high efficiency turkey and gas steam boiler? Which is more cost-effective? There will be new users are asked coal-fired steam boiler and gas steam boiler which is more cost-effective in a number of economic operation? Believed to be ready to buy a steam boiler of every business relationship or personally, with you today, I will work together to analyze these two boilers in operating costs to do a comparison. First, the first point to analyze procurement costs: Because gas steam boiler in the annex above techniques and configurations to be clear lead and coal-fired steam boiler, gas steam boiler supporting a dedicated burner, put the cost of just one burner price opened, so that the same tonnage of steam boilers, steam boilers high gas prices than coal-fired steam boilers and more. The second point to analyze construction costs: The costs mainly from the boiler room, boiler tubes of steam investment funds. Where the coal-fired steam boiler because more appropriate auxiliary equipment, so in the boiler room construction funds to be more. There is a gas steam boiler automatic control operation, and automatic alarm and automatic protection function. Connected to the gas pipeline, the burner will automatically supply costs can effectively save staff. Coal-fired steam boiler because of the need of coal on the program, so in terms of personnel expenses wage will be larger. The third point to analyze the environmental cost: major review means that the coal-fired steam boilers now more stringent. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used. The fourth point to analyze the cost of fuel: coal-fired steam boiler will be much higher than the steam boilers in gas fuels. After analyzing the above four points of view on coal in order to save operating costs more than gas steam boiler steam boiler, but coal-fired steam boiler steam boiler environmentally friendly than gas in environmental protection, environmental pollution is now increasing in recent years, so the state to environmental pollution control is relatively strict, so in accordance with the requirements of environmental protection point of view has an advantage gas steam boiler.

6 tons adjusting a combustion gas distributor 4t coal steam boiler high efficiency turkey, normal combustion boiler three basic aspects of indicators include a uniform supply of the fuel, reasonable ventilation, adjustment the combustion. 1, to maintain the high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100 ~ 1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. 2, fuel ash to reduce ash content in the combustibles to be below 10%. 3, reducing the temperature of the boiler flue gas exhaust gas temperature should be controlled below 200 ℃. 4, holding furnace negative excess air boiler is 1.2 to 1.4, by adjusting the balance of the blowers to maintain the furnace pressure is -20 ~ -30Pa. 5, the thermal efficiency of the boiler to improve the thermal efficiency of the boiler should be kept above 60%. II. Combustion Adjustment 1, the amount of fuel to air required for combustion and the amount of a reasonable distribution. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. 2, the thickness of the seam and seam thickness configuration grate speed is 80 ~ 120mm grate speed at high, middle and low profile configuration of several commonly used methods:. 9a rapid combustion of thin seam b c thick seam in low combustion. 3 thick seam combustion speed, the segment with the wind blowing principle: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. Normal combustion conditions are: fuel from the coal at the beginning of the fire shutter 300mm, uniform flames, the fire bed formation, at the end of combustion from the end of the grate 300 ~ 500mm. 4. maintain proper furnace temperature to avoid coking. The fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. 6. The residence time of the fuel on the grate in less than 30 minutes.

If within the natural gas boiler wear how to do? Off If there is detailed examination within the natural gas boiler wear how to do? Detailed examination is the key, fuel management is equally important. According to health and time natural gas boiler, we can plan a reasonable wear health check. When using the fuel, we strictly control the particle size of coal and limestone. Should strictly control the size of the bed material. Boiler waste should be handled. Boiler slag to be treated before discharge. Natural gas boiler should be installed in the heat of use, ease of installation. Hot water pipes should not be too long. It should have a good insulating layer. Hot water output to the end of the pipe should be suitably inclined. A water supply source should be equipped with a control valve. Of emissions, natural gas boiler chimney should extend to the outside, the outlet should be higher than the boiler 1.5 to 2M. If you want to reduce the impact on water wall tube, air pressure and air volume can be adjusted appropriately, effectively reduce the wear and tear of the water wall. Check the standby time is generally down or stop. To check items include leak wear, sealing the furnace and the furnace wall of smoke. In the event of wear, the need for timely repair and welding, to ensure the normal operation of the distributor 4t coal steam boiler high efficiency turkey. In general, before the gas-fired combustion of fossil fuels need to be filled in the combustion chamber, fossil fuel and bed material and recyclable materials in air speed, strength and stiffness of the shed fully integrated. Wind bottom means upwardly within the core region. Movement of the outer annular region of downwardly along the walls of the flow of boiler water, thereby prolonging the residence time of the coal particles in the furnace. Mineral particles, large amounts of ash and flue gas contains large amounts of fly ash particles, which continue to cause rapid wear of the water wall tube, wall thickness wear thin, resulting in wear and tear.

20th Meeting of the Standing Committee of People's Congress of the fourth Jinzhong City, approved the Thirteenth People's Congress Standing Committee of Shanxi Province, the seventh meeting since January 1, 2019 the formal implementation of the "Jinzhong City coal pollution prevention and control regulations "(the" Ordinance ").

1, Municipal People's Government shall determine the total amount of coal required control objectives, the development of coal-fired reduction and clean energy transformation plan and organize the implementation, reduce the proportion of coal in primary energy consumption structure in accordance with the requirements of the provincial government and city environmental protection.

2, Municipal People's Government shall designate built-up area for the city ban on coal zone and gradually extended to improve the quality of atmospheric environment on request. Counties (cities, districts) need to improve the people's government should ban on coal zone demarcated according to the ambient air quality.

May, ban coal-fired power plant area, central heating stations and raw coal units shall establish a coal purchase and sale of its products archives management, and self-purchase contract is signed or change within fifteen days, the number of coal procurement and information submitted to the seat of county government department in charge of energy.

6, city and county (city, district) people's government should promote the local conditions of the administrative regions of central heating, coal to electricity, coal gas and other clean energy alternative to coal-fired work. Encourage towns, rural areas to promote the use of clean energy living stove.

9, city and county (city, district) people's government should strengthen the management of civil bulk coal regions other than coal ban areas, to determine the clean coal supply companies, establish and improve civil cleaner fuels coal procurement, storage, supply mechanism to protect the clean coal supply.

10, city and county (city, district) people's government market supervision and management departments should be included in the annual coal-fired coal sampling plans to strengthen quality supervision and inspection, and to the public inspection results.

11, coal-fired power plants, district heating stations and boiler units to use raw coal output and single kiln production process should be in line with national standards and local regulations or policies. Any unit or individual may manufacture, import, sale and use do not meet environmental protection standards of boilers, furnaces.

12, supporting the construction of coal-fired units should use air pollution control equipment and facilities to maintain normal and stable operation, pollutant discharge should meet the standards set by the state and local levels. Encourage the use of coal-fired units to implement ultra-low emissions transformation in accordance with the requirements of environmental protection.