household gas pressure water tube boiler manufacturers

The two series of oil and gas household pressure water tube boiler manufacturerss produced by ZBG are condensed low-nitrogen environmentally friendly boilers. Low nitrogen technology is used to achieve low nitrogen emissions from boilers. The boiler is equipped with a condenser and an economizer to absorb the sensible heat in the high-temperature flue gas discharged from the boiler and the latent heat released by the condensation of water vapor to improve the thermal efficiency of the boiler. These two boilers are also fast-assembling boilers, which are compact in structure, easy to transport, easy to install and short in cycle.

Since more than six months since the household pressure water tube boiler manufacturers equipment, heating and hot water supply well, our technical staff also view real-time remote monitoring and control through the use of the boiler to the scene, Baiyun Quan Lake hotel management staff related to our technical staff gave very great encouragement and affirmation. --customer feedback

ZG also manufactures high efficiency, multi fuel Industrial water tube Boilers & Steam Boiler based on technology acquired, with whom we had over 60 Years of technical collaboration. It can supply household pressure water tube boiler manufacturerss upto 270 TPH capacity, steam at pressure upto 5.28Mpa. and temperatures up to 330. ZG has a large proven reference list of more than 1000 installations completed worldwide in last 6 decades. Water tube boiler fuel can be solid fuel, gas and oil fuel.The water-tube boilers described above are usually of a large capacity.

Henan Gas Burner common faults and solutions 1, Henan combustion gas powered household pressure water tube boiler manufacturers, press the start, the motor does not turn the gas boiler Henan Faulty motor does not turn: (1) lack of pressure lock (2) solenoid valves lax, joints leak, check the lock (3) thermal relay opens (4) condition circuit has at least one is not satisfied (water level, pressure, temperature, and the programmable controller is powered starter) Henan gas boiler motor does not turn exclusion measures: (1) adjusting the air to a predetermined value (2) cleaning or repair of the solenoid valve the pipe joint (3) is not damaged by the checking device is reset and the motor current (4) check the water level, pressure, temperature gauge 2 if, after the normal purging before the start, but misfire Henan gas boiler fault cause misfiring: (1) is less than the amount of electric anger (2) solenoid valve does not work (the main valve, an ignition valve) (3) solenoid burned (4) unstable gas pressure (5) is too large air volume Henan gas boiler misfire Remedy: (1) inspection and repair line (2) renewal (3) to adjust the pressure to a predetermined value (4) decreases with the wind, to reduce the throttle opening