21mw oil fired hot water boiler in central heating

Why 21mw fired hot water boiler in central heating heating more energy efficient, more environmentally friendly: generally used for heating hot water boilers, but the need to use less steam production process. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. Because it is more energy efficient than steam boiler, more environmentally friendly. First of all, in terms of fuel consumption, hot water heating than the steam boiler heating savings of 20% to 40% of fuel, this amount is very impressive. Summed up for two reasons: First, it does not condensate and heat loss due to evaporation of the secondary, two hot water heating pipe is heated by the use of special materials, as thin as possible to meet pipeline needs, heat loss is small. Heat loss due to the steam heating pipe caused by steam leakage large.

Pressure fuel boilers interpretation of the overall daily operation and maintenance of oil-fired boilers with atmospheric corrosion knowledge structure, including boiler and auxiliary equipment of two parts. Boiler furnace, drum, burner, water wall superheater, economizer, air preheater, and the furnace wall, etc. The main frame member constituting the core part of the steam production, called boiler. Boiler body is in two main parts and drum furnace. Also known as the furnace combustion chamber, fuel combustion for space. The solid fuel on to the grate, referred to as a fire bed combustion furnace Stoker, also known as fire bed furnace; solid fuel furnace liquid, gas or pulverized, is injected into the combustion chamber is called the fire chamber burner, also known as the furnace fire chamber; air coal particles burn hold it was boiling, and the furnace is inferior fuel suitable for combustion is called fluidized bed furnace, also called fluidized bed furnace; coal particles so that an air flow rotated at high speed, and strongly called fire cylindrical cyclone furnace hearth. Boiler pressure fuel daily operation and maintenance link and chemical corrosion, turbine attendant prepare enough desalinated water, oxygen, water passing temperature no higher than the drum wall temperature 50 ℃; Sheung during hot drum wall temperature should be after the temperature of the metal is not more than 40 ℃ before a new installation or repair departments boiler Feed records an indication of expansion. Sheung summer time less than 2 hours, at least 4 hours in winter, when the temperature and Sheung drum wall temperature difference of less than 40 how ℃ boiler reheater corrosion protection? after turbine fight gate, boiler guarantee a blower, an induced draft fan is running the best cross retain two oil gun. turn reheaters to the empty exhaust steam reheater hydrophobic doors and air doors corrosion, anti-corrosion of the reheater steam temperature is lower than a predetermined deg.] C for 400 control drum water level within an allowable range. anticorrosive time less than 20 minutes after stopping two oil gun operation. guarantee furnace pressure when 50--100Pa, each of the flaps open, baffle for ventilation less than 5 minutes, stop sending, fan, each of the flaps closed tailgate may be appropriate to accelerate Sheung speed.

How to maintain steam boiler 1, when maintaining boiler, must cut off the power supply, must release pressure. 2, burners should be removed from boiler body every two months, and other foreign bodies such as carbon deposit and dust should be removed seriously. The photo-electric tube is polished once a month. The fuel filter should always be cleaned and filtered. Carefully clean the inner filter screen of the oil pump and do not destroy the gasket. The burner shall not run without oil to prevent damage to the oil pump. 3, the water level gauge shall be kept clean at all times and rinsed once a day by opening the cleaning valve to ensure the water level is clear. 4. The safety valve shall be pulled once a day in case of rust failure. 5, When the steam boiler stops running for a long time The power supply should be cut off and the maintenance work should be done: (1) dry maintenance, discharging the furnace water after the furnace is stopped, rinsing away the dirt in the furnace, drying the pot with a small burner fire (the burning time should not be too long, so as not to damage the boiler), Then, after all the boiler gas has been discharged, all pipe valves will be closed and checked every three months. (2), wet maintenance shall be applied to boilers with a period not exceeding one month, and the boiler water will be discharged after the shutdown, and the clean and full water will be discharged. Cut off the power supply and close the valve.

After installation and commissioning fast Boiler professional and technical personnel, two 21mw fired hot water boiler in central heatings to provide our bodies quickly into the orbit of the normal operation. Meanwhile, the design of energy-saving equipment also effectively improve the thermal efficiency of the boiler, saved us a huge amount of fuel costs. --customer feedback