Best Selling 10t oil steam boiler Turkey

High resistance best selling 10t steam boiler turkey gas handling system: 1, gas steam boiler pressure gauge, water level gauge, safety, sewage, a water supply valve, a steam valve, check whether the performance requirements, other valves in good condition. Gas hot water boiler with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. 2, the boiler Zidongkongzhi device system, comprising a flame detector, level, temperature detection, a variety of interlocks and alarm means, display control system performance states to meet the requirements. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace.

Electric heating best selling 10t steam boiler turkey Products electric heating steam boiler is the electrical energy into heat of a new type of electric equipment, following the same "boiler Safety Supervision" and the manufacturing industry standard in design. By electric heating equipment, heating equipment consisting of furnace, safety accessories, strong, weak control systems and other components all have national compulsory safety certification mark. Full immersion heating elements fixed to the flange, easy to change freely. Circuit design using fuses, electrical harmonics are controlled to ensure effective protection of the safety of the power supply circuit. Boiler power control system using a host and a separated manner, to avoid disturbing the electrical and thermal aging electrical components. Product description features: ① may provide a direct product structure analysis, gas-assisted technology application support, precision molds (gas assisted mold), plastic products (gas assisted products), heat distortion temperature trace full service support molding technology; ② can be provided directly in the gas-assisted injection molding technique involves analysis of the product, mold design, optimization support mold, gas-assisted manufacturing mold, gas-assisted process support, a reasonable selection, and other gas-assisted equipment; many enterprises effective use of gas-assisted technology to enhance the quality of products, reduce production costs provide a strong technical support. ③ may be provided directly to all sets of gas-assisted injection molding system devices patents involved in the development of the company designed the special requirements for gas-assisted production, production and closely monitor, such as high reliability of compressed air purification system, maintenance-free three-year nitrogen separation system, the introduction of foreign produce high quality clean diaphragm high pressure compression system (compression pressure nitrogen completely solve the hidden oil contamination), and gas-assisted pressure control with high precision: the temperature change may provide direct heat trace technique involves molding All patents sets of equipment, including steam-assisted injection molding equipment, electric assisted molding apparatus, hot water and hot oil auxiliary molding equipment accessory, ④ may be provided directly GAIM equipment, heat molding temperature change trace all the technical equipment involved service, spare parts service, customers do not need to face before other vendors run the preparatory work: (1) the operator must know the location of the working principle of the boiler, all kinds of accessories, performance and working methods. (2), check the oil combustion, and each nozzle connection, power supply and the burner, the pump, the boiler installation accessory. (3), a clear main steam valve open, after closing the normal close it. (4), water level gauge inspection, confirmation flexible water level, normal position. (5), the pressure regulator is properly tuned, regulate combustion damper.

Around the city to promote the coal to gas project, the major institutions of the heating system put forward higher requirements. Central Conservatory of Music is available to students and teachers clean, safe, comfortable, energy-efficient heating environment, protect the health of teachers and students, to transform the traditional boiler treatment. Praise fast boiler Willie sharp series obtained in the transformation of low nitrogen boiler major institutions in Beijing, the Central Conservatory of Music in late 2017 with the signing of fast boiler boiler purchase contract, ordered six Willy sharp series V6-99, to for the entire school's heating facilities.

Combustion gas treatment unit and a fault, gas boiler burner ignition misfire rod reasons: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Measures following five: Clear, renewal, adjust the distance, change and switching transformer. Second, gas boiler, but spark ignition rods misfire reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Measures are: Clear; first wash, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel); Check tubing and oil filters, insulation equipment ; remove peripheral screw pump, carefully remove the cover inside out oil network, with immersion oil; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing instability reasons: 1, the air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, fuel oil boiler water. Action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; approximately set to about 50 deg.] C; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Processing methods: ① the oil line check valve is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.