drying natural gas hot water boiler manufacturers

Oil gas fired boiler for sale in Canada supplied by ZBG can be divided into two types according to the output, one is oil gas fired drying hot water boiler manufacturers and it is mainly applied to supply hot water for school, hospital and many other institutions and the other is oil gas fired steam boiler which is mainly used to supply steam to meet the demand of power generation, disinfection and many other applications.

Especially now that inflation, as the price of water, coal, natural gas will increasingly rise, while the price of electricity will become increasingly low. Electric boiler product power consumption of about 100 watts per square meter per hour. There are many responsible companies have committed to electric heating, calculated at 100 square meters house, from November 15 - ended March 15, a total of four months, electricity is not more than 2000 yuan. Ensure that the temperature 18 degrees to 22 degrees. If you use more than the normal local central heating.

Earlier this year, fast Boiler successful bidder Guan China Fortune Foundation Real Estate Development Co., Ltd. Gas boiler tender offers to other companies low nitrogen gas pipe 80 tons of steam boilers and steam 40 tons each in Taiwan, with the use of 1.5 million square meters to meet the heating demand. The introduction of various environmental policies throughout the country to improve environmental protection in all walks of life. Among the improvements, the reduction of nitrogen oxide (NOx) emissions as the primary problem.

Gas boiler shutdown normal shutdown process step is one step in the process of boiler operation is essential to understand the shutdown processing methods to ensure more long-term operating life of boiler. When the boiler the following faults can temporarily shutdown for maintenance. Expansion port, leakage rivet joints; tube, the waterwall tubes, damage to the heating surface tube leakage; drum in contact with the flue gas, set top box, a heat insulating material off the downcomer; water supply system, a combustion system, the occurrence of breakage safety accessories . Shutdown of the gas boiler normal (full shutdown, maintenance shutdown) Step 1, in order to stop the burner, for closing the valve. At the same time feed water to the boiler, 2cm above the normal water level reaches the stop water supply, reduce the pressure. 2, close the main steam valve, open the traps, steam boiler, water cut off. 3, the electric boiler feed water control valve closed and the manual valve, boiler feed water cut. 4, steam pressure may be lowered to the water supply and drainage operations alternately 0, the pot water temperature is gradually lowered. When the temperature dropped to 50 ℃ (not hot when hand potshell head with or touch), the entire pot of water may be drained. Should be preceded by opening the drain valve or air valve above the boiler, this time into the furnace maintenance, shutdown must be kept slow cooling, rapid cooling is prohibited. From the shutdown to be able to enter the furnace maintenance, cooling time is not less than 24 hours. 5, sales of more than 24 shutdown, to total gas supply valve is closed, opens the gas pipe to completely drain the subjective dispensing gas.