20t Natural Gas steam boiler Dealer Brunei

Steam boiler is one of the indispensable devices in the pharmaceutical industry, decoction of Chinese medicine, medicine drying, sterilization, cooking gum, drying, tabletting and capsule production processes, a large amount of steam will be used. West Libang Pharmaceutical Co., Ltd. is a pharmaceutical research and development, production and sales of high-tech enterprises, the existing anesthesia, cardiovascular, child immunization, pharmaceutical raw materials, pharmaceutical excipients, nutrition series of six automated production lines. With the increasing strength of China's environmental protection, some high-pollution devices are making the transition to clean environmental protection. Libang Pharmaceutical respond positively to national coal to gas policy, decided to change the existing coal-fired boilers to clean better gas 20t steam boiler dealer brunei. Fast boiler with strong comprehensive strength in the field of clean energy, Libang Pharmaceutical after conducting comprehensive consideration, determined to cooperate with the fast boiler. The two sides further understanding, party fast technical engineers according to production needs state power, and soon its development of specific solutions for its recommendation of a 6 tons of steam condensing gas steam boiler (WNS6-1.25-Y.Q).

50, when arranged inside the boiler room to note a safety distance, the front end of the boiler ready spacing of not less than 2/3 of the length of the furnace, and not less than 2 m; vertical boiler can be shortened; bulk boiler is not less than 4 m and does not affect the blast furnace operation and maintenance. 2, the boiler side and rear channel spacing of not less than 0.8 m, and should meet the operational and maintenance (such as replacement tube bundle cleaning, stirring the fire, etc.) requirements. 3, the top horizontal boiler headroom not less than 2 m; vertical boiler top clearance height to facilitate the operation and maintenance; headroom boiler room the other channels, should not be less than 2 meters, when the passage of time and no need to operate its headroom height of 0.7 meters. 4, the boiler room is provided for two or more boilers, the boiler the distance between adjacent not less than 1 to 1.5 times the cylinder diameter of the boiler. 5, the boiler room is generally preferred fireman operation chamber provided, on the total rated greater than or equal evaporation 4t / h 20t steam boiler dealer brunei (heating or hot water boiler is equal to or greater than 2.8MW) must be provided stoker operating room. Electric boiler tank may be provided in front of the boiler, and to ensure the art to fireman facing boiler water gauge, pressure gauge and other instruments during operation. 6, to the total rated evaporation 2t / h fuel gas boiler room to be provided or water spray foam fire extinguisher system, should outdoor outdoor fire hydrant, other fire-fighting equipment should also have the boiler room. 7, the fuel in the boiler room daily oil tank, the oil pump is generally not located in the boiler room, between daily oil tank, the oil pump between the application of the fire resistance of greater than 2.00h wall, the fire resistance of greater than 1.50h floor spaced from the other parts. Daily fuel tank between the boiler room and the door between the oil pump should be able to self-closing fire doors Class A, and let the oil block measures. Household upper tank return pipe to be provided, should be greater than the oil return pipe back to the oil pump. 8, an oil tank and all piping must have a reliable electrostatic grounding, the grounding resistance should not exceed 30 ohms. 9, gas boiler room boiler design should also comply with the relevant safety requirements of gas boiler room.

Electric 20t steam boiler dealer brunei flue of accumulating a certain amount of soot how to deal with? Electric steam boiler furnace cleaning backpass long-term non-stop, accumulating a certain amount of soot or carbon black. Solution: When the temperature drops below the flue 50 ℃, check before entering the flue tail heating surface, and should completely remove the flue soot. If not burning, can be re-started ignition; if burning, should be replaced, repaired burning member; large negative pressure of the combustion chamber, so that gas will be no time to burn into the electric steam boiler tail. Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C and more stable during 1h openable inspection hole inspection, after checking element determines the source of fire, the ventilation fans before starting. When shutdown or electric steam boiler fire, air gun valve is not closed. Solution: strengthen the electric steam boiler feed water and turn on the water, open the valve or economizer recirculation tube to protect the economizer being burnt; lower start, the furnace temperature during shutdown, unburned fuel in the furnace . Solution: fire extinguishing devices immediately into steam, carbon dioxide or other fire extinguishing devices; burn improperly adjusted, with insufficient wind or with the wind unreasonable. Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan.

Installation and internal gas 20t steam boiler dealer brunei induced draft fan of the basic structure of the gas steam boiler configuration and cited the difference between the internal structure of the gas boiler steam turbines, gas steam boiler with induced draft fan needs it? Can be equipped with fan, but depends on the type of boiler and burner models, different designs, different configuration, such as boiler combustion and pressurized combustion positive pressure, negative pressure combustion needs to Fan, the combustion pressure is also equipped with the induced draft fan . Gas-fired steam boiler price? I do not know the local fuel prices. Meanwhile, steam boiler tons of gas consumption to about 7 degrees, and tons of gas boiler steam power was insufficient. Other aspects of superior gas or gas, such as environmental protection, operating environment, repair and maintenance. Gas-fired steam boiler water is quite easy to detect what instrument? Gas steam boiler is necessary to detect the water hardness and the total alkali content, to use these indicators generally chemically very convenient hardness complexometric titration on the line. Of course there are specialized equipment, and many, hardness tester, portable hardness portable Taobao has sold analyzer. I always feel that consumed 6 tons of water, steam and water is water present as at the tri-state nature. Water states are: ice, water, steam. Consumed water into steam, which mass is not changed, the change in energy occurs therein. Specific concept tonnage evaporated ton of water for an hour is defined as a tonnage if you tons of water evaporation is defined as N N tonnage. The answer is yes, the tonnage of the boiler is arbitrary, as long as you can do the right boiler design any tonnage. The difference between gas steam boiler and boiler construction of fuel gas steam? Because of the different fuels, have the following differences: a burner fuel steam boiler, gas boiler, the combustion method of a fixed grate, and a fluidized bed furnace pulverized coal burners and the like.