Dealer Gas or Oil fired steam boiler Industrial

4 tons of dealer or oil fired steam boiler industrial before firing what needs to be done to prepare a deal boiler conduct a comprehensive inspection before Sheung Shui, the water is softened before boiler water filling. 2, Sheung Shui should check whether there is water leakage valve, leaks should be immediately removed when found. 3, the check Sheung water temperature, pressure gauges, water level, no good production of inlet and outlet valves, smoke profile, said shutter is flexible, the flue gas channel is smooth duct, each cleaning doors are tight. 4, before firing coal with water 8-10%.

3 ton biomass dealer or oil fired steam boiler industrial in Sri Lanka Features

1.3 ton biomass steam boiler in Sri Lanka have advanced three pass wet back design:adopts the most sophisticated three returns all wet back structure,thread smoke tube structure, weld joint with high quality.

2.3 ton biomass steam boiler in Sri Lanka with advanced manufacturing equipment endows Safe and reliable property:adopts corrugated furnace lamps, multi-chain protection. Water level, steam pressure, gas pressure protection. And before leaving factory, all the boiler have been rigorous inspection and testing, including pressure tests and X-ray detection.

3.3 ton biomass steam boiler in Sri Lanka have large boiler proper heating area:adopts unique design of a large combustion chamber which increases the radiation heating furnace area, reducing the size of the boiler, reducing the NOX emissions.

In a number of bidders, the party quickly ready gas water tube boiler with its unique advantages of low nitrogen come out on top; the low nitrogen gas water tube boiler has the following advantages. 1, boiler factory ready, body welding, manufacturing completed in the factory, quality is the best guarantee to ensure the long-term safe and reliable operation of the boiler. 2, a small work site installation, short cycle, the boiler body all-membrane wall structure, effectively reduce heat loss boilers, to improve the thermal efficiency of the boiler. 3, boiler furnace, convection and rational use of two-pass arrangement flue gas velocity, effective control of the flue gas resistance, no fan, lower operating power consumption, energy saving. 4, micro-pressure combustion, the boiler to prevent the air leakage phenomenon, to effectively control exhaust excess air coefficient, reducing heat losses, improved boiler efficiency. 5, with forced water circulation system, the flow rate of each process are selected in accordance with the recommended standard upper limit value, to ensure that the cold boiled heating surface does not occur too, causing water hammer or squib; preventing sedimentation oxygen corrosion and impurities in the water, to avoid heat boiler accident damaged surface;? burner flame, gas overpressure or low pressure, 15 kinds of safety warning and fault protection device leakage protection, gas, comprehensive guarantee safe operation of boilers;? intelligent integration operation control system, with touch-screen operation Dual purely manual control buttons and functions.

Fuel gas boiler automatic instrument sets the control means are included which according to the "industrial boilers Complete supply" and provides fuel gas boiler automated instrument packages supply shall include at least the following: (1) evaporation of 4t / h and 4t / h or less boiler 1 ) detection. Water gauge, vapor pressure gauges (including saturated and superheated), water pressure gauge, water thermometer, thermometer smoke, steam flow rate calculation (including less than evaporation lt / h boiler). Oil temperature, oil pressure, oil level indication, calculates fuel (gas boiler as temperature, pressure, gas), furnace exit gas temperature indication. Evaporation of 4t / h boiler flue gas oxygen content should have, furnace pressure, temperature economizer export indication. 2) regulation. Position of formula (only for non-economizer of the boiler) or continuous feedwater automatic control, automatic adjustment of a combustion boiler the combustion of heavy oil should automatically adjust the oil temperature, air pressure gas boiler there should be automatically adjusted. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. 4) Other. Auxiliary electrical control box, gas boilers should be equipped with explosion-proof electrical control equipment. (2) evaporation of 6t / h and above 6t / h boiler 1) detected. Water gauge, vapor pressure gauges (including superheated saturated), water pressure gauge, water thermometer, thermometer, smoke, water, steam pressure, water pressure indicator, calculated water flow, steam flow indication, recording and computing, oil temperature, oil pressure, oil level indication, indication and calculating the amount of oil (gas boiler as temperature, pressure, gas), economizer inlet and outlet water temperature indication, furnace exit gas temperature, exhaust gas temperature, air pressure, furnace pressure indication, Sheng Mei an inlet, an outlet indicated negative, indicating flue gas oxygen content, there is an outlet air temperature should be indicative of the boiler air preheater, the boiler superheater, there should be recorded and the superheated steam temperature indication. 2) regulation. Continuous automatic adjustment of water supply, drum, induced draft fan damper flap opening remote control, remote pump control valve (an intake gas boiler control valve), a heavy oil combustion boiler should automatically adjust the oil, gas boiler should automatically adjust the air pressure, there is superheater boiler there should automatically adjust the temperature of superheated steam. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over voltage protection and alarm indication of heart steam, oil accident alarm system, furnace flame protection, fuel gas overpressure protection or low temperature alarm and protection. Boiler superheater should have more limited temperature of superheated steam and an alarm indication. 4) control and the other. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.