locomotive gas steam normal pressure boiler manufacturers

When using a chemical plant locomotive steam normal pressure boiler manufacturerss have what precautions when using chemical plant boiler what precautions? The main industrial production of industrial boiler to provide heat to maintain the power production plant operations, mainly using a steam boiler of electricity or natural gas industry, the other is based on coal as a raw material by the waste heat recovery operation to maintain the production of traditional electric power industrial boilers, widely used in industrial production. What precautions when using chemical plant boiler? (1) When using industrial boilers, the operator should not only have relevant operational knowledge and skills, but also prohibits unauthorized departure, the boiler is no state in the operation to reduce accidents. Pressure boiler boiler water level is too high or too large. (2) staff to improve the working pressure of industrial boilers, should undergo a rigorous technical evaluation of relevant professional departments, before adjustments. Pressure gauge and safety valve to avoid failure resulting industrial boiler overpressure mislead the operator allowed to adjust. Meanwhile, to strengthen skills related to operating personnel, the timely processing of boiler operation anomalies. (3) prior to use industrial boilers, the boiler should be fully checked structure and current and voltage is within the normal range. To avoid unreasonable boiler structure, poor weld quality, safety accessories related failures caused by industrial accidents occurred in the boiler during operation, and should be sufficient for boiler water treatment prior to use to reduce the incidence of accidents in the run and run.

Recently, Shandong Province, issued a "thermal power plant air pollutant emission standards (DB37 / 664-2019 instead of DB37 / 664-2013)". Standards will be implemented on September 7, 2019.

First, the standard applicable to the use of a single output 65t / h or more layers in addition to coal-fired burner, furnace stoker boiler or steam generator; single output 65t / h or more oil, gas, or steam generation boiler; single output 65t / h or more power using steam boilers other fuels; pulverized coal fired boilers of various capacities; various capacities gas turbine. Gas turbine integrated gasification combined cycle power generation is performed in this standard gas turbine exhaust gas as a fuel limit.

Environmental Impact Assessment II. This standard is applicable to the existing project management of emissions of air pollutants, as well as the above-mentioned new construction, renovation, expansion projects, environmental protection facilities design, environmental protection facilities acceptance, pollution permits and air pollutants after putting into operation emissions management.

Oil-fired locomotive steam normal pressure boiler manufacturers safety instructions oil-fired boiler is one of many hot water boiler to one of how to prevent boiler fuel boiler appears to be abnormal use it? First, to ensure the normal operation of the fuel in the boiler feed water quality and quality of qualified soda, to reduce the water wall tube fouling and corrosion, strengthen supervision and boiler water boiler water when found unqualified, should increase the number of times a given row; while the flue gas flow rate control , especially when the flue gas velocity in the corridor, during installation and servicing, should minimize the distance between the wall and the superheater tubes, while the distance between the tubes to uniformly as possible. second, the fuel boost heating boiler carried out in strict accordance with procedures, control the speed boost. were lower header sewage water wall work required to build the water cycle as soon as possible, promptly switched the gun to ensure uniform heating surface is heated to eliminate half of combustion, eliminating thermal excursions. third, do a good job adjusting fuel combustion boiler, the flame deflection preventing, controlling coal fineness noted that, with a reasonable air to prevent coking, reduces thermal excursions, to prevent the tail reburning fuel boiler; boiler steam parameters be closely monitored, and the main indicators of the amount of water evaporation and the like, to prevent pressure Release, full of water, water accident. fourth, strengthening sootblower sootblower and management, serious fouling preventing heating surface, when there is found furnace coking phenomenon, should be increased blowing Gray times, ensuring good water wall heat sink; overheating problem of the presence of long-term heating surface, installation of thermal supervision controlling temperature measuring points; expansion to ensure accurate indication means using oil-fired boiler units must be fully taken into account the safety problems. in the inspection process must be meticulous in place. to ensure the personal safety of the unit.

Pressure locomotive steam normal pressure boiler manufacturerss Products of the non-pressure hot water boiler, also called pressure boilers, boiler usually refers to the top does not bear the water column static pressure of the heating system. That is quite an open hot water tank. Meaning pressure boiler: boiler body opening to the atmosphere. In any conditions, the boiler at the water line are zero gauge pressure boiler. Pressure boilers Model consists of three parts, connected by a hyphen between the parts. Categories: pressure hot water boiler is mainly classified by fuel can be divided into CLDR (CWDR) often piezoelectric hot water boiler, CLHS-YQ (CWNS-YQ) pressure fuel (gas) hot water boilers, pressure coal-fired hot water boilers. Model: The first part of the model by atmospheric pressure boiler code, pot-type code, combustion equipment code, the rated thermal power four sections. Boiler pressure is represented by C code example: CLSG0.35; 95/70; W12 represents a vertical pipe fixed grate boiler pressure, the rated thermal power of 0.35 mW, rated outlet water temperature was 95 deg.] C, the nominal temperature of the water inlet. 70 ℃, burning anthracite class I, a second design of the boiler. Product Structure: The overall structure of pressure boilers and boiler auxiliary equipment including two parts. Boiler furnace, drum, burner, water wall superheater, economizer, air preheater, and the furnace wall, etc. The main frame member constituting the core part of the steam production, called boiler. Boiler body is in two main parts and drum furnace. Also known as the furnace combustion chamber, fuel combustion for space. The solid fuel on to the grate, referred to as a fire bed combustion furnace Stoker, also known as fire bed furnace; solid fuel furnace liquid, gas or pulverized, is injected into the combustion chamber is called the fire chamber burner, also known as the furnace fire chamber; air coal particles burn hold it was boiling, and the furnace is inferior fuel suitable for combustion is called fluidized bed furnace, also called fluidized bed furnace; coal particles so that an air flow rotated at high speed, and strongly called fire cylindrical cyclone furnace hearth. Furnace design needs to fully consider the characteristics of the fuel used. Each boiler should be fueled with the original design of the fuel. Boilers running economy and reliability are likely to vary greatly reduced when using the characteristics of fuel combustion. And the natural circulation drum is repeatedly forced circulation boiler receiving feedwater to the economizer, the coupling cycle and supplying saturated steam superheater cylindrical vessel. Simplified drum made from high quality steel plate, is one of the heaviest components of the boiler. Safety knowledge; boiler is a high-temperature, high-pressure thermal equipment, is one of special equipment, widely used in government agencies, public companies and all walks of life, are dangerous and special equipment. Event of an accident involving public safety, it will cause huge losses to the state and people's lives and property. For public safety, people's lives and property safety, according to the State Council, "Regulations on Safety Supervision of Special Equipment", the boiler should use full attention the following matters: 1, should be accompanied by safety technical specifications of the factory boiler design documents, product quality certification, safety and the use and maintenance instructions, supervision and inspection certificate (safety supervision, inspection and performance certificate). 2, boiler installation, maintenance, alteration. Engaged in the installation of the boiler, maintenance, renovation of the unit shall obtain special equipment installation and maintenance certificates issued by the Provincial Quality and Technical Supervision, before engaging in the boiler installation, maintenance, alteration. Construction unit before construction will be prepared for installation, maintenance, alteration in writing inform the special equipment safety supervision and management department of the municipality or district, and will start informing sent to the local county level Quality and Technical Supervision for the record, told immediately after construction. 3, inspection of boiler installation, maintenance, transformation. After construction, the construction unit To State Quality and Technical Supervision of Special Equipment Inspection and hydrostatic testing of the boiler installation supervisory inspection declaration. After passing by the State Quality and Technical Supervision, State Special Equipment Inspection, County of Quality and Technical Supervision involved in overall acceptance. 4, registration boiler. After the boiler inspection, the use of units must be in accordance with the "special equipment registration and use of management rules", fill "boiler (census) Registration Form", the State Quality and Technical Supervision to register and obtain a "registration certificate to use special equipment safety . " 5, operation of the boiler. Boiler operation must be performed by trained and qualified to obtain "special equipment operator certificate" certified personnel to operate, must strictly abide by the rules and eight systems, six record. 6, check the boiler. Periodic inspection of boiler once a year, not be used without safety periodic inspection of boilers. Safety accessories safety valve of the boiler regular inspection once a year, pressure gauge biannually verified, may not be used without the periodic inspection of the safety accessories. 7, non-pressure boilers will be installed for the boiler pressure. Do not use water level gauge, safety valve, pressure gauge three safety accessories insufficiency boiler. Daily operation and maintenance: ⒈ chemical contact, turbine attendant prepare enough desalinated water, oxygen, water passing temperature no higher than the drum wall temperature 50 ℃; Sheung during hot water temperature should not be to the drum wall metal temperature difference greater than 40 ℃ .⒉ new installation or after recording before overhaul boiler Feed expansion departments indicated .⒊ Sheung summer time less than 2 hours, at least 4 hours in winter, when the temperature and Sheung drum wall temperature difference of less than 40 ℃ how reheater be preserved? ⒈ turbine after playing brakes, boilers ensure a blower, an induced draft fan is running the best cross reserved two oil gun .⒉ open reheaters to the empty exhaust steam reheater hydrophobic doors and air doors corrosion, anti-corrosion of the reheater steam temperature is lower than a predetermined deg.] C for 400 .⒊ control drum water level within the permissible range .⒋ preservation time less than 20 minutes after stopping two oil gun operation guaranteed .⒌ when the furnace pressure 50--100Pa, each of the flaps open, baffle for ventilation less than 5 minutes, stop sending, fan, each of the flaps closed tailgate may be appropriate to accelerate Sheung speed.