gas fired Vacuum Boiler price in North America

Price Price hot water fired vacuum boiler price in north america hot water boiler: gas vacuum hot water boiler use of the characteristics of different water pressure environment of different boiling points. At normal atmospheric pressure, the boiling point of water is 100 deg.] C, vacuum gas hot water boiler operating pressure in the range -0.07Mpa less. Corresponding boiling temperature of water is less than 93 deg.] C, vacuum gas at the operating pressure of the hot water boiler, the combustion temperature rises to the water boiling temperature, the steam boiling surface to produce the same temperature, volatile vapors absorb large amounts of heat. At this time, water is injected into the heat exchanger of the boiler. After the inner tube was heated to an outer cold administered heated steam flows out through the steam pipe outside the cold water cooled heat exchanger is condensed into water droplets, the water cycle is completed in vacuo. 1. smoke tube was added in the process, improve the heat transfer effect of making the arrangement more concentrated. With a square overall structure independent spray, beautiful shape of the separation. three. Large furnace techniques: effectively increasing the heat radiation area of ​​the unit, to reduce the nitrogen oxide emissions. 4. Boiler water using a high water to ensure that water within the boiler fouling and not oxidized. All wet back shell type three-way structure, static heating, excess heat .6, actively control the whole system, it does not require special duty. Seven. Unique pulse level detection circuit having a reliable performance. 8. inlet / outlet temperature display easier to control the operation of the vacuum and hot water boiler operating segment. 9, receiving advanced multilayer insulated glass wool, heat loss is small. Henan fast boiler gas hot water boiler with three vacuum pressure safety system: automatic safety explosion-proof valve in the discharge control: when the internal pressure of the boiler continues to rise, the explosion-proof valve due to EHV broken, releasing the pressure inside the boiler, to ensure safe operation of the boiler; Digital pressure switch: imported from Japan digital pressure switch, detecting a change in the pot at any degree of vacuum, when the pressure is too high, side off: opening vent automatic safety alarm: the boiler when the internal pressure becomes slightly positive, automatic vibration security alarm explosion-proof valve, cutting off the power boiler.

The comparison of fired vacuum boiler price in north america failure rate: 1, vacuum degree of vacuum boiler in vacuum boiler * important index of stable operation of furnace, and four main factors that often affect vacuum degree: 1) whether there is leakage point in boiler body and valve, instrument, and so on. At present, including imported valves and meters can not ensure that there is no leakage within 3 years. 2) it is inevitable that failure of control part, boiler controller and negative pressure, pressure controller will also happen in operation, for example, the failure rate of domestic controller is even higher. 3) vacuum pump, three-way solenoid valve is working normally or not. As a result of the vacuum pump, the three-way solenoid valve is not operating very often and is originally installed Mouth also easy to appear the card dead and in the operation occurs the fault. 4) the load can not change abruptly, the boiler load change is very normal for the boiler, generally, the boiler can meet the load regulation of 30% ~ 100%. The above faults will cause the change of the vacuum degree of the boiler. At this time, the gas tightness of the boiler, whether the control part is normal or not, the vacuum pump, the three-way solenoid valve are normal or not, and the change of load should be checked. If all normal should be checked negative pressure and pressure controller settings, all normal vacuum recovery boiler can still be normal, otherwise the boiler should be shut down and overhauled all-round inspection. The failure maintenance rate of vacuum boiler in actual operation is higher than that of existing boiler. Pressure steam boiler, control requirements are higher than steam boiler. 2. The normal pressure boiler only has the basic time, temperature, water level control, hot water boiler controller selected the original inlet, the failure rate is relatively low. There is no need to maintain vacuum control equipment, without complex control equipment, personnel operation requirements are simpler than vacuum boilers, the probability of downtime maintenance is less, the actual operation of hot water boiler is much more stable. The comparison of boiler safety: 1. If the vacuum degree of the vacuum boiler is not guaranteed due to the above four factors, it may cause the boiler pressure to rise rapidly, and the boiler body is a closed structure, and the operator may cause the boiler pressure to rise rapidly. If paralyzed, it is possible to become the danger of pressured steam boiler, the vacuum operation of vacuum boiler is more safe based on the premise that the vacuum degree of boiler can not appear problem. 2. The atmospheric hot water boiler of atmospheric pressure boiler is as simple as boiling water, and no fault will cause boiler pressure. The boiler www.boilermanufactory.com is more safe and reliable, and it is really free of any danger.

Gas fired vacuum boiler price in north america vacuum boiler describes a vacuum heat medium to rely on evaporation and condensation boiling mass transfer heat exchanger to heat the feed water heat exchange apparatus. Of water at different pressures, different boiling points. Atmospheric boiling point of water is about 100 ℃, and its boiling point at a pressure only 7mmHg 5 ℃. Vacuum boiler working pressure range of 200mmHg-500mmHg, corresponding to the water temperature was 66-90 ℃. Vacuum boiler composed of two parts evaporator heat exchanger and the condensing heat exchanger. An evaporator heat exchanger and the combustion boiler is provided with convection heating surface, fuel released by combustion heat of the heat-generating medium the corresponding saturated vapor pressure. Vapor rises to the condensation in the condenser section is condensed releasing latent heat of vaporization to transfer heat to the heat exchanger for hot water, the hot water heated to a certain temperature to the heat user, the condensed condensate returned to the evaporator transducer vaporization heat in the evaporator, this cycle continuously supplying heat to the outside world. Safe and reliable: Vacuum boiler always run under negative pressure, no danger of explosion, part of a separate heat exchanger can be pressure 1.6MPa pressure, and stable operation, a significant feature of atmospheric pressure boiler and can not be compared. Efficiency: self-developed integrated heat storage cluster rotation and multi-zone multi-chamber heat exchanger technology, a substantial increase in thermal efficiency, the left and right exhaust gas temperature 100 ℃, than similar fuel gas boiler energy saving up to 25%. Durable: indirect heating method of production of hot water, hot water and the heat medium independently, to avoid fouling the machine body (water side heat medium), the vacuum furnace body and the furnace oxygen-free environment to eliminate oxygen corrosion in vivo, combined with self-developed double buffering module flat conducting structure, thus extending the life of the boiler. Multi-purpose: to provide simultaneous multiple different temperatures of hot water, to meet the various needs of users central air-conditioning, heating, sanitary hot water, high-level swimming pool, guest houses, hotels and other hot water supply, process water is also available for all types of industrial and mining enterprises . Ultra-fast: the ignition system to work about 20 minutes. Set diverse places: the installation location choose basement, floors, intermediate floors and roof, etc., saving the land for construction. No need to qualification: the boiler is not a "boiler and pressure vessel safety regulations," the specified range, without operator qualification. Automatic Temperature Control: the hot water outlet temperature can be freely set in the range ≤90 deg.] C, the microcomputer energy can be automatically adjusted according to the heat load, the hot water temperature control in the most optimal state. System design is simple: the hot water heat exchanger by indirect heat medium heating water directly supplied to the user, the system can reduce the heat exchangers and other components, making the system simpler design. Simple operation and maintenance: vacuum hot water boiler control microcomputer Chinese man-machine dialogue, to set free the opening, off time, stepless temperature setting switch with removable water heating system configuration, while the front opening, the smoke box structure, and all of the smoke tube joints can be visible and easy inspection, maintenance. Environmental compliance: the design of the boiler using the burnout rate and the rate of heat transfer multi-zone multi-room eddy current rotary heat exchanger technology to improve fuel gas, with imports of brand-name European burners, fuel combustion more fully, low noise, NOx emissions a minimum amount in the same boiler, in full compliance with increasingly stringent environmental requirements.

At the end of 2017, China Guodian is located in Jiangxi Province Wanan Hydropower Plant After evaluating the situation, some of the steam fired vacuum boiler price in north america used to purchase much-needed daily work. Sales Manager fast boiler combined with the actual situation of the power plant for its recommendation 2 0.5 tons of electrically heated steam boilers.