mechanical natural gas hot water pipe boiler supplier

To get industrial gas mechanical hot water pipe boiler supplier safe operation must be done to check the work of industrial gas-fired boiler pressure vessel belongs, in our country there are strict and clear standards of production and operation. In particular boiler in operation, should always pay attention to whether the safe operation of the boiler, auxiliary equipment and operation of each respective instrument valves is stable. Therefore, gas steam boiler room is necessary to establish a sound system of inspection tours and boiler room equipment maintenance system. First, natural gas boiler room mobile inspection system 1, in order to ensure the normal operation of the boiler and its accessory equipment, timely detection of problems, fireman on duty personnel at least once every half hour tour inspection. 2. Check gas boiler burners, pressure gauge, thermometer, circulation pump, water supply pump, water softening, safety accessories, an instrument, secondary instrument is functioning properly. 3, check whether the abnormal changes in various types of signal lights. 4, check the water level in the tank gas boiler, feed pumps, circulating pump and motor bearing temperature and pump lubricating parts are normal. 5, check the position of the gas valve and the steam boiler feedwater pressure switch valve is normal. 6, mobile inspection found problems in time, and test results recorded in the log boiler and accessory equipment inside. Second, gas-fired equipment maintenance system 1, two gas-fired boiler on the pressure gauge value is not the same timely maintenance, to ensure reflect the actual operation of the boiler pressure. 2, gas boiler pressure gauge damage, when the dial is not clear, timely replacement. 3, rotating machinery lubricating oil passage remains open, the oil cup to maintain a certain oil level. 4, run, run, drip, leak repair valves can be repaired, replaced. 5, inspection, maintenance and feed pumps, circulating pumps and pump valves open is flexible, single-stream if the door is closed tight. 6. Check the gas-fired secondary instrument is normal. 7, to remove dust on the equipment and the accessory device. 8, check the gas boiler safety valve manually turn on the water after closed trials are tight. Automatically turn on the water, blowing off steam at least once a week. 9, pressure gauges operate properly flushed at least once a week. Trap maintenance once a month. 10, over-temperature, overpressure alarms, overpressure interlock device checks at least once a month, and maintenance. Gas boiler pressure gauge, water level gauge and a safety valve are the three safety accessories on the gas steam boiler, with particular attention.

The quality of the horizontal gas fired mechanical hot water pipe boiler supplier directly influence the property of the boiler. Meanwhile the alerting and protection directly influence the safety and liability of the oil protection. The control system of the gas fired boiler main includes burner control, the control of the water level,pump constant pressure for oil control.

Since this year, Qingyang City, Gansu Province Environmental Protection Bureau to continue to improve air quality at the core, in order to implement the Air Pollution Control Act as the main line, adhere to the rule by the people, source control, increase the comprehensive management of air pollution, construction of accurate and efficient and fine air pollution comprehensive prevention and control system, to fight air pollution control tough fight.

Qingyang Xifeng Kowloon City Road, South Street neighborhood community coal-fired boilers in accordance with the "clear" work requirements, continue to increase coal-fired boilers "cleared" efforts, multi-pronged, comprehensive treatment of the families of Xifeng Animal Husbandry Bureau building coal-fired boilers were removed.

Since coal-fired boilers to carry out "clear" its work, Kowloon South attaches great importance to the community, seven coal-fired boilers within the jurisdiction of actively deployed, timely follow-up, held a special arrangement will, continue to strengthen measures. In the community workers and urged many times to persuade, the District Animal Husbandry Bureau family member courtyard boiler successfully removed. After removal of this coal-fired boilers, coal-fired boiler demolition community task has been completed.

Phase out coal-fired boilers is an important measure to improve the air quality of the environment, but also the strong expectations of the masses. The demolition action, and effectively promote the area to carry out "the image of the city, the level of management" to work for the creation of a national civilized city to make its due contribution.

Steam mechanical hot water pipe boiler supplier should be noted that when Di operating high specification and steam boiler efficiency matters, strong firepower, Di is a common production equipment, but also has some of its own Di dangerous if used improperly, it will cause unnecessary trouble. So master the instructions for use steam boilers, clear during the operation Di Di precautions are necessary. Note that when then the next, the editor based on years of experience, the use of steam boilers with compliance and Di operational considerations summarized below. A steam boiler Use: When the company receives a steam boiler, boiler Di for normal use, as well as business operators Di their own safety, must strictly abide by the "Production Safety Law," "Boiler and Pressure Vessel Safety Supervision Provisional Regulations" "Steam Boiler the relevant provisions of security technology supervision regulations ". This applies to a fixed pressure steam boiler water as a medium, comprising a coal-fired steam boiler, a steam boiler fuel, gas steam boiler. Use of the boiler plant Di technology should have the appropriate certificate, have both technical documentation and construction quality boiler installation supporting information. Enterprises must attach great importance to the boiler safety. Appoint a full-time staff responsible for managing the boiler equipment, improve the management of the use of boilers in accordance with code requirements. Formulate ensure the safe operation of the boiler structure according to the type of boiler, combustion and explosion-proof requirements and procedures, fire prevention, anti-virus and other security management system and the accident approach, in accordance with its strict implementation. Do not drink alcohol and posts and off-site. Boiler should be regularly repair and maintenance, the unit can not be forced to use any security risk boiler. Should be repaired before construction drawings and technical solutions. Repair of technical expertise required reference standards and relevant technical regulations boiler. After completion of repairs, should the pattern, material quality certificate, a certificate of quality inspection and repair and other technical information is stored in the technical archives plant boilers. Non-boiler room operator banned from entering the workplace. Foreign workers must be accompanied by the relevant approval of the leadership or before entering Second, the need to pay attention to Di operational considerations when using the steam boiler: 1, before the boiler must be familiar with the operation manual, simply to protect the safety of the operator and the normal use of the device Di, before starting inspection whether the power supply voltage and the normal operation of the water, close the drain valve, open the water supply valve and check whether the pump stuck, stuck if the water pump cover remove the fan, scroll to the motor shaft can be turned on flexible state inspection or replacement of parts for boilers Turn off the power to avoid live work dangerous. 2, electric control boxes, pump motors and other parts should avoid damp water to prevent burning boiler should pay attention to keep clean, according to the boiler water quality requirements, be sure to install a water softener in use, because they do not use a water softener can cause boiler fouling severe cases can cause burst pipes cut short the life of the boiler. 3, if not in accordance with the provisions of the use of water treatment equipment caused by the above situations are not covered under the warranty, please pay attention when using sewage. To discharge once a day and with a discharge pressure of 0.1MPa-0.15MPa, can prevent clogging pipes, sewage pipes should be properly connected to prevent burns, the flexibility of the safety valve should overhaul, at least once a month to quickly pull the lever to check the safety valve flexibility it off and back seats, the safety valve should be regularly every year to the local technical supervision for verification.