gas fired condensing water tube hot water boiler manufacturers

Multi-fuel steam boiler protection water protection Fuel steam boiler: boiler water level gauge plate supporting one to two, should always be compared with each other, findings indicate inconsistency shall be corrected immediately. Class water level should be flushed, to determine their true level. While the water level comes electrode rod can accurately capture level signal to an alarm or a pump control. A steam pressure protection, the pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switches, automatic control chain protection or other control lines. Using pressure controllers and electrical contacts, the vapor pressure can overpressure alarm; single adjustable pressure controller or dual fire burning fire the actual operating pressure. 2, the safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. Flame protection: imported burner having a flame protection device, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged of residual internal combustible gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. Self-locking power failure protection: Under the emergency power supply is interrupted, the boiler shutdown immediately self-locking, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.

Learn the difference between pay professionals work and waste boiler and boiler feed water for boilers of knowledge and understanding, we will continue this work, because the only way to keep abreast of professional knowledge about the boiler, and the knowledge and flexibility to apply their knowledge applied to practice, then, to ensure that the boiler had good results, avoid misuse. 1. What is the boiler professionals work? Boiler professionals work, the specific name for the boiler professional engineers and professionals work into operation and maintenance professionals work. Run professionals work: the development of operational procedures, technical monitoring in the boiler, if the boiler fails problems during operation, timely analysis and guidance to operating personnel discharge failure, ensure that the boiler safe operation. Also, record the operating parameters of the boiler, to provide accurate data for the boiler overhaul. Maintenance professionals work: development of maintenance procedures and maintenance scheduling and parts planning, at the same time, but also to develop maintenance programs, guidance personnel for maintenance work as maintenance procedures. Boiler feed water and boiler feed water 2. Is there a difference? Boiler feed water, which is from the plant to the Water and then through oxygen between the boiler feed pump into the boiler economizer soft water, boiler feed water is from the chemical water softener after the plant by chemical treatment. Although they are soft water, boiler feed water, but more complicated, but also the need for oxygen and heated before entering the boiler. So, boiler feed water and boiler feed water is different. 3. central boiler furnace temperature to be controlled in a range? The boiler is the first inspection within or outside the check? Central boiler furnace temperature is generally controlled within the required range of 900 ℃ -1100 ℃. Is the first in the boiler inspection, conducted after the external examination within the inspection is completed, if the problem has been found in the inspection process, and after dealing with external inspection out of the issue. In addition, we also need to know that, in the boiler inspection is conducted every two years, external examination is conducted once a year. 4. What is the waste boiler? Familiar with and understand the waste before the boiler, first look at waste boiler. Waste boiler, which means that the exhaust gas, waste and waste water. Exhaust: no fuel to burn in the combustion waste air emissions, mainly including soot, sulfur dioxide, nitrogen oxides and other waste gases. Waste: solid waste produced after combustion of the fuel, including cinder, oil residue and other such waste. Waste water: Some water is not used in the boiler emissions, comprising a compound, mixture, suspension, and salt, alkali larger boiler water, in addition, also water, sludge and the like fluffy precipitate. Waste boiler, which is the use of some of these techniques and recycling waste utilization, and reduce noise to produce secondary economic benefits.

Hot water boiler water filling boiler considerations and parameters between boiler pressure fired condensing water tube hot water boiler manufacturers of this kind in which the boiler is a common and frequently used species, but also in terms of all of us, need to have a comprehensive knowledge and understanding, because the only way to be correct and rational use of hot water boilers and have good results, but also to avoid misuse and adverse impact. 1. boiler parameters, whether on the same hot water boiler and steam boiler? From a professional point of view, the parameters of hot water boilers and steam boilers are not exactly the same, there are some differences, because the parameters of the boiler steam boiler steam boiler is concerned is the number of generated operating pressure and temperature steam, hot water thermal power boiler in terms refers to the boiler, the water supply and return water pressure and temperature. In addition, its different parameters, it corresponds to the unit is not the same. 2. Boiler Feed water pressure Cautions Boiler Feed pressure hot water process, there are some considerations, which is specifically as follows: (1) Sheung boiler heating system should be carried out separately, can not be together, because the boiler when you stop running between the boiler and the system is cut off. At the operational level, is you want to Sheung Shui to low water boiler expansion tank, then the system can Sheung Shui. Water Supply System, which can be used to perform Sheung pressure of the water filling the water system, if the pressure is less than water, circulating pumps can be used for water filling system. (2) If the system is filled with water by the circulation pump, which is specific to the operation: the boiler return pipe inlet valve is closed and the circulating pump will be multiplexed into the water pressure in the system until the system after the completion of charging water, then adjust the water level in the boiler. Meanwhile, while the system is filled with water, to be noted that the exhaust gas system. 3.1.4MV electric heating hot water boiler, heating area which is how much? 1.4MV electrically heated hot water boiler, its heating area is calculated, it needs to know the required heating power per square meter, heating, boiler pipes and boiler efficiency loss of these parameters, in order to obtain specific numerical values. If the heat required for heating power per square meter is 80W / h, boiler conduit 20% loss, then, the electrically heated hot water boiler heating area of ​​10,000 m2. However, this is the theoretical value, there may be some discrepancies with the actual value, without taking into account other external factors in this case.

New R & D building fast-party group, is a technology demonstration, research and development as an integrated office building. On the first floor exhibition hall design is simple and modern technology, integration of human-computer interaction, virtual reality, projection, graphic panels, simulation models and other advanced means of interactive multimedia display a variety of boiler technology, creating a precedent for the domestic boiler industry technology show. 360 holographic ---- wing tube interactive rejection screen technology - condensing technology Slide TV - premix --FGR intelligent human-computer interaction technology modeling techniques - Remote monitoring