22 ton 1 25mpa gas steam boiler

In Malaysia, there are lots of biomass fuel like palm shell and palm fiber, we recommend SZL or DHL type for using water tube boiler. If the steam capacity is less than 25t/h, the SZL will be the best choice, whereas if the steam capacity is more than 25t/h and less than 100t/h, DHL corner tube boiler could be chosen. In addition, the gas or diesel is another kind of source for the local user, so SZS type could be recommended.

0.5 tons gas boiler introduced: 0.5 tons of gas boiler Description: 0.5 tons of gas boiler imported burner, automatic programmed control, automatic purge blower, electronic auto-ignition, spontaneous combustion and gas, (air) automatically adjusting the ratio of wind oil good atomization, combustion, low NOX, energy saving and environmental protection. Under normal circumstances, when the boiler steam pressure reaches the set value, the burner combustion is automatically stopped, when the steam pressure is below the set value, the burner is automatically started. When the abnormal phenomenon of the fuel, air intake, fault lights, the output sequencer will immediately stop the fuel, burner shut down automatically.

The reason you need to know the boiler energy consumption (reheat steam temperature) reheat steam temperature problems 1. Circumstances reheat temperature rises 1.1 Move boiler furnace flame center, furnace outlet temperature increases (see main economic indicators No. 5 boiler exhaust gas temperature). 1.2 coal increased too fast. 1.3 Excess air amount is increased. 1.4 pulverizing system start-stop. 1.5 Automatic control of the reheater desuperheating water improper adjustment. 1.6 reheater sootblowing time poor choice. 1.7 feed water temperature is low. 1.8 the high pressure turbine exhaust temperature is high. Next to the 1.9 high leakage, high reheater inlet temperature. Hot and cold extraction section greater then 1.10. 1.11 boiler heating surface design is unreasonable, over-temperature reheater tube wall, forced cooling operation. 2. Reheat the following partial flame temperature is lowered center 2.1: burner tilt deviation, hem; burner is switched from the upper to the lower layer, the lower layer or to an excessive amount of the powder; volatile coal fraction is increased, the pulverized coal thinning, water reduction. 2.2 reheater heating surface fouling, slagging, fouling the interior. 2.3 Save reheat the heated drain valve. 2.4 automatic adjustment inappropriate, excessive reheater desuperheating water. 2.5 feedwater temperature. 2.6 economizer and water wall sootblowing time poor choice. 2.7 reduce the amount of coal too fast. 2.8 # 1, # 2 high pressure heater is disabled, increasing the reheated steam flow.

At the same time, there is potential merchants who come from abroad, the technical personnel of the fast balls "surrounded" and continuing to explore the strengths and weaknesses of domestic and foreign products, and to seek opportunities for cooperation. Show time rush across three days, bring us the possibilities of cooperation. Fast square booth through a unique "three-sense" approach sight, touch and feel, so that every person visiting the boiler can more fully grasp the details of knowledge; the presence of each "fast side" and can feel responsibility, different demand for clean energy at home and abroad make us pay more attention to customers' true feelings. In ending this occasion, we have a clear goal, that is: Benchmarking European and American advanced equipment and boiler design, to a higher level of technology, more in-depth boiler systems continue to study. While the company's own comprehensive capabilities continue to the forefront of world power on par, but we need to take over the banner, leading the Chinese clean boiler market, a higher level.