electricity natural gas boiler manufacturers

Gas oil-fired electricity natural gas boiler manufacturers room ventilation system designed along with economic development, energy supply and demand changes in the relationship between environmental protection requirements increase, electricity and oil and natural gas in recent years, increasingly used gas oil-fired boiler. The gas oil-fired boiler room design related to people's life and property security of the country, but also can ensure the normal operation of critical boiler. In addition to the location of the boiler room and capacity to meet the relevant specifications, the design of the ventilation system which is also an important element in the design of the boiler room. However, due to the content of conventional ventilation and manual specification relates to small, there is no specific calculation method is given, designed to bring some difficulties. In this paper, problems in this area, combined with engineering experience of the author, make some analysis, calculation and discussion, put forward their views, for your reference. 1. Design Principles gas fuel boiler room ventilation system

1, the safety valve should be mounted vertically in a high position in the pot business, set box.

2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve.

3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly.

4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm.

5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve.

6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust.

7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve.

8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve.

The only example of an ultra-low nitrogen oxide emissions through electricity natural gas boiler manufacturerss Enterprise Test - fast boiler, the production of gas hot water boiler, gas steam boiler, condensing boiler integrated, NOx emissions is far below the required standards, environmental protection departments successfully passed the test and get the user's praise.

What electricity natural gas boiler manufacturers need for attention? Now oil, fuel, natural gas is a very scarce resource, when used in mining will be accompanied by a series of pollution problems, the face of this situation, boiler has become an urgent need to solve the problem, you know boiler and a large, there are dangerous equipment, so the transformation process we need to pay attention to some problems to be able to make it to transform all aspects of security smoothly, Here we give details of the content of transformation should be noted: 1, pay attention to dismantle the step of performing boiler prior to the transformation, to dismantle its main and auxiliary engines, but how demolition, operators need to advance the development of a detailed demolition plan according to the boiler case, then one by one followed by removal of clear indicators based on the removal step, not indiscriminate demolition otherwise it will cause safety accidents; 2, pay attention to the transformation of the furnace to know a lot of focus on the steps of the boiler furnace to transform all around, the general professional boiler when the company will be re-engineered to the furnace pouring new furnace, replace the old furnace, but also so that the original After the furnace arch tube can not have been affected by high temperature burning, the flame away from the center point, this will allow the furnace to become more durable; 3, do not forget a lot of people think it is testing everything will be fine in the boiler after the completion of renovation work, in actual fact, but also to test work after the transformation of the boiler, the boiler body to hydrostatic pressure test point five times. If the last test pass, then, to complete the delivery. The average person will ignore, I hope we can notice this; when the boiler, hope everyone can have some knowledge of three of its top hope in the transformation may be noted that the above-mentioned problems, avoid errors caused by safety problems , if you are looking for a trustworthy company's boiler, then you can consult a few good brands of the company, then let the company to own the corresponding boiler rehabilitation programs, in order to examine the strength of the company's transformation.