gas condensing steam boiler with energy saver

Meanwhile, at the annual meeting of the excellent performance of employees also distributed millet television and different incentives such as bonuses, is intended to encourage employees to continue their efforts to create more success in 2019. In the meeting, the president has placed us deep hopes in 2019 to focus the project, focus on value, cohesion output! Let the wind and waves, temper forward to the next five-year development strategy for the company's work starting point, in order to achieve the objectives as an important breakthrough, and jointly create a more brilliant 2019!

What are the reasons gas condensing steam boiler with energy saver popular? What is the reason gas steam boiler is popular? 1: the use of more environmentally friendly cleaning gas steam boiler. Gas hot water boiler with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing users enjoy the reputation as the cost of natural gas is a clean fuel, do not emit harmful gases and soot in the combustion process. Therefore, do not pollute the air and the environment. Soot or carbon dioxide generated by conventional coal-fired boilers not only affect the air quality, but affect the health. Therefore, the use of gas steam boilers are environmental requirements. 2: high thermal efficiency of the reaction gas used in the thermal efficiency of the steam boiler is faster than the reaction of other aspects of the boiler, because natural, natural gas is used as a pollution-free high heat of combustion of the fuel, the higher the fire, heat faster switching speed, steam from the water pot and continue to release the faster. Compared with other coal-fired and oil-fired boilers, thermal efficiency is the fastest, most effective. Third: run more intelligent gas steam boiler does not require manual operation, does not require complex operational intelligence Zidongkongzhi whole process. All the work process only requires prior set all the parameters you can use. Gas steam boiler design according to user requirements, start, stop, automatically adjust the water supply load. Occur during operation of any abnormalities can also achieve self-diagnostics, interrupts combustion, sound and light alarm.

Teach you how to properly operate a condensing steam boiler with energy saver: steam boiler before use to conduct the inspection of the damaged insulation, burner check to see whether the normal operation, also check to ensure that the open position of the valve is correct, check the device controlled device instrumentation and safety equipment accessories, equipment must meet the requirements. Steam boiler furnace entry point confirmation are: Open the valve before and after the oil circulation pump, oil heating flow valve opens, the liquid level in the sump reasonable mediate high position, confirmed that the gas pressure before ignition of the gas burner to the range, the power supply is normal .

The design of the boiler room fire interval is how much? Section 13.1.1 boiler fire hazard classification and fire rating should meet the following requirements: a room, boiler production plant belongs to class D, to the condensing steam boiler with energy saver rated evaporation 4t / h, when the hot water boiler rated output is greater than 2.8MW, boiler room building fire resistance rating of not less than two; steam boiler equal to or less than the rated evaporation 4t / h, when the hot water boiler is equal to or less than the rated output 2.8MW, between the boiler building fire resistance rating of not less than three; II. when the inter-tank, and a pump room between the oil heater are class C production plant, its construction fire resistance rating of not less than two, disposed within said room between the auxiliary boiler room, a room should be set apart from other firewall; III. between the gas regulator production plant belonging to Group a, which is not less than two building fire rating, should be provided between the boiler room and the immediate neighborhood regulator firewall spaced boiler room, which doors open outwards and should not be passed directly the boiler room, the ground should not spark floor. Referring again to the provisions of Article 5.2.2 GB50016-2006 "architectural design code for fire protection," according to fire resistance rating.