Hospital Natural Gas Hot Water Pipe Boiler Dealer

In the national standard of water quality standard, the water quality index of hot water hospital hot water pipe boiler dealer stipulates that the total hardness of water supply for chemical treatment outside furnace is less than 0.6 mmol / L. In recent years, in order to reduce the operating cost of heating units, some hot water gas-fired steam boilers have been overloaded due to the use of class Ⅲ bituminous coal as fuel instead of class Ⅱ bituminous coal designed to replace the designed type Ⅱ bituminous coal. During the maintenance in summer, it is found that the overloading boiler water wall tube fouling problem is more prominent, some boilers even occur tube burst accident. Why is heating hot water boiler overloaded, scale and even burst tube? Because the calorific value of class Ⅲ bituminous coal is higher, the type Ⅲ bituminous coal of the same weight is burned instead of the designed class Ⅱ bituminous coal. Bituminous coal increases the circulation of boiler riser is not absolute equilibrium, the geometric difference of riser and the heat load are different, so there is inevitably the deviation of flow rate between the risers. Due to the overloading operation of the boiler, some riser tubes are easy to overheat boiling because the flow rate is small, and the wall temperature is higher than the designed wall temperature, so that the scale and even the tube burst are easy to occur. How to prevent the boiler from scaling when overloaded? The heating hot water boiler operates under overload because of the scaling after the superheated boiling. Steam is produced in the process of superheated boiling. The water quality requirement of gas steam boiler is less than 0.03 mmol / L, which is much lower than that of hot water boiler. Water quality requirements. Based on the above reasons, the feed water hardness of heating hot water boiler is reduced, and the scaling phenomenon is eliminated by reducing 0.6mmol/L to 0.03mmol/L.

The price of gas hospital hot water pipe boiler dealer characteristics and maintenance of gas boilers Products: gas boiler includes a gas water boiler, gas hot water boiler, gas steam boilers, gas hot water boiler which is also known as gas heating boilers and gas boilers bath, as the name suggests refers to gas boiler it is the fuel for the gas boilers, gas boilers and oil-fired boiler, electric boiler compared to the most economical, most people have opted for a gas boiler as steam, heating, boiler equipment for bathing. Gas boiler Features: 1, large font display temperature, easy to grasp and boiler operating conditions of the system, the water temperature can be freely set from 10 ℃ to 90 ℃, automatic boiler or heating system to provide users with life, bath with hot water. 2, the control system controls the circulation pump start and stop in accordance with the temperature of boiler water, boiler water circulating pump starts when the water reaches an upper limit temperature, lower than the hot water circulation pump stops when the water temperature lower limit. 3, three horizontal gas bath boiler return all wet back structure, using a large furnace, rough smoke tube design, increased furnace radiation heat absorption, the effective energy saving. Using threaded pipe and waveform furnace, greatly enhanced heat transfer effect, greatly saving fuel consumption. 4, while the machine is equipped with thermal protection (ultrahigh temperature furnace, the burner is automatically stopped and an alarm buzzer, the second over protection (the boiler shell temperature exceeds 105 deg.] C, the secondary circuit is automatically cut off), the lack of anti-dry protection of water (when water is lower than the low water level of the furnace, the boiler is stopped and an alarm beep), a boiler leakage protection (the control system detects electrical leakage, short circuit, automatically cut off the power) .5, according to the boiler pressure design , no pressure in the boiler state, there is no safety hazard with advanced multi-layer insulation centrifugal glass wool, steel for packaging famous white color, heat loss, beauty care and anti-rust gas boiler: 1, gas-fired boiler during operation Note the following points: (1) does not allow pressurized gas boiler furnace combustion or smoke, because the manhole cover easy to burn stoker; not on the water bottom (2) gas boiler ground surface to prevent corrosion .2 moisture, gas boiler runs every 2-3 weeks, should be checked once a .3, gas boiler run after every 3-6 months, should conduct a comprehensive inspection shutdown maintenance: (1) internal and external gas boiler inspection, such as by Weld parts, steel inside and outside for corrosion phenomenon, if found serious deficiencies should be repaired, if the repairs were not serious defects also until the next shutdown, if there is suspicious, but does not affect safety, should make a record for future reference; (2) can be checked and the water boiler primer coating to prevent corrosion .4, gas boilers and boiler paint base at least once a year .5, often of unused gas boiler maintenance methods: dry and wet two kinds, one month shutdown, care should be taken dry method, wet shutdown can be less than one month regimen (1) dry regimen: after shutdown of the furnace to the discharge water will completely remove the dirt inside , rinse, drying in the furnace with Weihuo (be careful not to fire), and then the bulk quicklime 10-30 millimeters in diameter installed sub-plate, placed in the drum, without contacting the metal with lime, quicklime by weight, calculated to the drum volume 8 kg per cubic meter, then all manholes, hand holes pipe valve closed, checked every three months, such as lime ingredients like broken, i.e. the need to replace the boiler should be re-run Quicklime and disk unloading (2) Wet regimen: After Shutdown of the water discharge furnace, the inside completely remove the dirt, rinse, refill treated water to the full, the water was heated to 100 deg.] C oven, so that the water exhaust gas out of the furnace, and then close all valves, cold climates where moisture can not support the use of law, so as not to damage the boiler furnace water freezes.

Note Di steam hospital hot water pipe boiler dealer steam boiler operational considerations should use great caution when using, because the slightest error will bring harm, so the operation should be more cautious, for a description of the use of steam boilers, process clear operation should pay attention It matters. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. According to many years of experience in the use of steam boilers, summarizes the operating steam boiler matters should be noted: First, before the boiler to be familiar with the use of manual, to protect the normal use of safety equipment and operating personnel fundamentally. Before starting, check the power supply voltage is operating properly and water, close the drain valve to open the water supply valve, the pump checks whether the jam, remove the blade cover, and the motor shaft to the flexible state to start the scroll machine. Check the boiler or the power off when changing accessories to avoid the risk caused by the charging operation. Secondly, the electronic control box, pumps, motors and other components should be avoided in order to prevent moisture absorption burning boiler should pay attention to maintaining clean, according to the relevant boiler water quality requirements, be sure to install a water softener use, because they do not use a water softener can cause boiler fouling, serious it can cause burst pipes, shortening the life of the boiler. Finally, if the above conditions are not covered by the warranty, if not used in accordance with the provisions of water treatment equipment, sewage note that when used. Emissions once a day, with pressure 0.1MPa-0.15MPa emissions to prevent clogging pipes, sewage pipes should be connected properly to prevent burns, the safety valve should be flexible maintenance plans, pull the lever at least once a month safety valve to check its take-off and elastic seat. Local Technical Supervision safety valve should be checked once a year.

Fast hospital hot water pipe boiler dealer strong technical team and perfect after-sales service to our left a deep impression, the successful completion of the boiler installation and commissioning work at a predetermined period. The company offered me two Taipower heating steam boilers, combined with the actual situation of our company, as we save a lot of fuel costs, thanks to fast boiler provides us with such high-quality products and peace of mind. --customer feedback