supermarket gas steam normal pressure water tube boiler dealer

Greater than 65t / h industrial supermarket steam normal pressure water tube boiler dealer of what air pollutant emission standards should be executed? A: The State Environmental Protection Administration, Central Division-standard [1993] No. 012 document pointed out that the emergence of a small number of parameters currently higher than GB1921-80 "industrial steam boiler parameters Series" and GB3166-82 "hot water boiler parameters Series" layer burning, stoker boiler, regardless of its use Zanan GB1327-91 execution. Therefore> 65t / h or more (except coal, circulating fluidized bed, and fuel, gas fired boilers) industrial boilers should be performed "boiler air pollutant emission standards."

How to observe whether steam supermarket steam normal pressure water tube boiler dealer is short of water and how to deal with itSteam boiler is a kind of energy conversion equipment. The energy input to the boiler is chemical energy in fuel, electric energy, heat energy of high temperature flue gas and so on. After boiler conversion, steam, high temperature water or organic heat carrier with certain heat energy is outputted out. Water level below the minimum safe water level, or invisible water level, water table glass tube (plate) appears white. The two-color water level meter shows all the gas-phase indication colors. Low water level alarm signals occur in high and low water level alarms. Low water level interlock device, water level below the specified value should stop the operation of fan, induced fan, grate reducer motor. There is also a sharp rise in superheater steam temperature above the normal outlet Steam temperature. The exhaust temperature of the boiler rises. The feed water flow rate is smaller than the steam flow rate, if the furnace tube or coal economizer tube rupture cause water shortage, the opposite phenomenon will occur. When the water shortage is serious, you can smell the scorching smell. When water shortage is serious, red water wall tube can be seen from the furnace door. When the water shortage is severe, the furnace tube may break, and a burst can be heard, steam and smoke will be ejected from the furnace door and the fire door. By calling water; for severe water shortage, it is necessary to stop the furnace urgently, and blindly feed water to the boiler. Reduce fuel, blast, draw wind, and supply water slowly when water is classified as a slight water shortage.

Recently, Binzhou City, Shandong Province High-tech District Supervisor Bureau to carry out special rectification actions supermarket steam normal pressure water tube boiler dealers within the region, mainly to effectively prevent and resolutely curb special equipment accidents from happening again, strengthen security principal responsibility.

Inspectors use of "without warning, went straight to the scene" way of checking for nine boiler units within the region conducted a comprehensive inspection, focusing on aspects of boiler operation, the operator of personal responsibility, troubleshooting, safety test accessories, etc. a comprehensive investigation. Long-term idle boiler, supervise the use of units in time for deactivation procedures; management is not in place, there are security risks of the use of units, ordered deadline to complete the hidden rectification. The campaigns, check out a total of more than 30 people, to identify risks at 8, at the completion of the rectification 8.

Next, Binzhou City High-tech Zone Market Authority will continue to strengthen law enforcement and inspection efforts, compacted layers of responsibility, and strengthen security consciousness, special equipment to protect the region's security situation continues to stabilize, escort for the economic development of high-tech zones.

More details gas supermarket steam normal pressure water tube boiler dealers should be promptly after use as a steam boiler plant drainage, heating, bath with gas boiler is a kind of fuel for the gas equipment (fuel gas-fired boilers), because it is compared with oil-fired boiler, electric boiler up more economical, which is widely used. After carrying out the gas boiler must turn on the water to be disabled. Why is that? We will come and detailed discussion about this issue today. To turn on the water when the gas boiler is disabled: gas boiler in the boiler water if the winter will put the cracking, there will be odor and summer long embroidered, so that the life of the boiler will be reduced. At the bottom of the boiler there is a turn on the water with the section of the door, then opened, gas boiler pipes in the water will flow back to the boiler, the boiler is done and the water on it. Water level controller SZB-IV (electrode type water level alarm) 1. When the normal level of + 30mm, pump control switch contacts are open, the pump stops working. 2. When the normal water level -30mm, pump control switch contacts in contact, the pump starts to work. 3. When the normal water level of + 50mm, a first group of electromagnets high gas boiler water level contacts the combined output high level alarm signal. 4. When the normal water level of the gas boiler -50mm, a second group of electromagnets in conjunction with the low water contact output low water level alarm signal.