Seller 1t Natural Gas steam boiler Malaysia

Boiler multiple protection: (1) the integration of boiler water level to protect water level and boiler design, the appearance of more compact appearance, accurately show the actual water level in the boiler body function. Coupled with dual independent electronic water level control system to achieve ultra-low water level in the boiler, low water level automatic adjustment function, the normal water level, high water level, ensure that the boiler in a variety of unforeseen circumstances foolproof, secure home. (2) steam pressure protection ☆ pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switch, other control lines or automatic control chain protection. Common pressure controller and pressure gauge, vapor pressure overpressure alarm can cut off the burner limit is reached; the pressure controller may be single or double fire burning fire the actual operating pressure regulator. ☆ safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. (3) having a burner flame protection flame protection inlet means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged combustible residual gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. (4) self-locking power failure protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.

When gas boiler outage, we should not panic, there must be the order of the operation, shut off the gas boiler. 1, the normal shutdown sequence, check the gas fired boiler fuel, gas, water shutdown valve meets the requirements; 2, off gas, coal boiler blowdown valve to prevent the surface of boiler drum cause other problems; 3, quickly closing the main steam valve prevent dehydration gas fired boiler drum; 4, close the supply valve and deaerator power switch and gas valve.

Using Ultraten wings condensation boiler technology has greatly enhanced heat the heating rate; silicon alloy material design to achieve the depth of the condensing heat exchanger, high efficiency, high heat transfer speed. "APH the T7" ready to use the factory mode, the system design is simple and clear, i.e. security that is used, the best burner performance debugging the factory, the user can simply set up at the installation site, connected to gas, water, to a flue , it covers an area of ​​greatly reduced.

3: Convenient

Gas-fired steam boilers are also more convenient to use in operation, so they will be favored by users of all enterprises. All natural gas pipelines are just as convenient as tap water for domestic use, and there are no problems with sustainable use. It eliminates the cumbersome work of using coal to transport or stack and clean coal cinder.