gas steam boiler 5th

First, when the flue temperature dropped to below 50 ℃ Solution: Check the tail may enter the flue if heated, while the flue thoroughly remove soot. No burning flue tail, can be re-started ignition; if burning, should be replaced, repaired burning member. Second, the combustion chamber when the negative pressure is too large Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C over 1 hour and stable, open the inspection hole inspection; after inspection after confirming the fire source, before start the fan ventilation. Third, shutdown or fire, air gun valve ajar solutions: reinforcing and electric steam boiler 5th feed water drainage, or open the valve economizer recirculation tube to protect the economizer is not burning. Fourth, Kai, during shutdown lower furnace temperature, a solution of unburned fuel in the furnace: extinguishing device immediately put into vapor, carbon dioxide or other devices off fire. Five burning improperly adjusted, with insufficient wind or with the wind unreasonable Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan. These are the methods of electric heating steam boiler fast boiler to provide you with the handling of soot in the chimney, if you use electric steam boilers, with more than five can control their own boiler equipment need to be cleared up the flue, and select the appropriate method .

Hot water boiler for users to solve the "coal" urgent at present, energy conservation and building sustainable economic model has become a national priority, but only our coal utilization hovering around 30%, far below the 78 % of the international average. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler 5th, biomass hot water boiler, biomass oil furnace. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing user fees Therefore, improving the utilization of coal combustion has become essential. Currently, coal-fired hot water boiler control system to achieve precise control and real-time monitoring. By controlling the water temperature, the fan speed to achieve a controlled, to ensure the stable combustion furnace pressure and coal, which saves coal, but also to ensure safety. Industrial production in the boiler and heating primary energy into secondary energy of important equipment, has been widely used in industrial production and daily life. Coal-fired hot water boiler control scheme is reasonable and convenient way to monitor, steady state operation, the whole process of thoughtful service, users get a good feedback. I believe in the future, coal-fired hot water boiler intelligent control scheme can serve a wider field of industrial production, as well as hotels, schools, hotels, residential heating, bath, hot water and other fields, coal cost savings for users, improve combustion efficiency, ensure the safe operation provide a solid guarantee. Completely solve the problem of long-term accumulation of the user, the water temperature stable. Water temperature set by the ambient temperature, grate speed difference adjustment according to the actual water temperature and the set temperature of the water, i.e. adjusting the amount of coal boiler, to ensure the stability of the water temperature. Outstanding energy saving. Grate speed changes to the feedforward signal, in conjunction with flue gas oxygen content signal or the furnace temperature, blower speed control using the PID algorithm, to ensure full combustion of the coal, to improve the utilization of coal, reduce emissions of harmful substances. Excellent safety performance. To change the fan speed as a feedforward signal, the PID control calculation and induced draft fan speed according to the furnace pressure value, to ensure the stability of the furnace pressure. This paper introduces a control algorithm based on the level of intelligence of the new big jump lag PID. After control of embodiment, given a certain waiting time to observe the effect, and to determine whether further embodiment control, multi-parameter input and multiple output control mode based on performance parameters.

Spark ignition rods gas boiler, but because the misfiring spark ignition rods gas boiler misfiring but the reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; For more information about oil oil oil, information technology please pay attention to the public number of oil rings. Check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. When the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change.

Our business-to-steam boiler 5th produces steam attaches great importance to the quality of good or bad, it will indirectly determine the quality of our food is produced dates. The fact that we choose fast boiler is correct. We are very grateful to our fast boiler manufacturing plant in a short time, installation and commissioning of these two steam boilers, advance our production line went into operation. --customer feedback