hot water boiler oil fueled

Continue to promote the comprehensive management of dust pollution, coal-fired pollution control to strengthen and deepen the industrial pollution control and related fields, etc., which are from governance "Xining City 2018 air pollution comprehensive management action plan." Xining City, the official launch of construction on the "Xining blue" and maintain the action. Aspects of dust, industrial pollution, coal pollution will increase management and control, to develop specific control measures for building a better Xining efforts.

Since the launching of "Xining blue" action in the coal-fired pollution control, Xining City has accumulated more than 3,000 tons of steam "coal to gas," the task of governance, the main city of the city "coal to gas" campaign to take the lead. With the further implementation of the Blue Sky Project, Xining substantial increase in utilization of clean energy, significantly improve air quality of the environment, it has been among the five northwestern provinces in the forefront of the capital city.

Taking into account the special Xining City, Qinghai-Tibet Plateau is located in the geographical location, the winter heating season is longer, coal dust is an important source of winter air pollution, while heating pipeline dredge more difficult, the implementation of the transformation plan will face difficulties pipeline reconstruction. To effectively improve urban air quality since 2013, Xining City, carry out a comprehensive "coal to gas" governance by supporting comprehensive measures upgrading natural gas pipeline network, such as the yellow car out of standard co-ordinate the promotion of winter clean, safe and efficient heating, achieved within the natural gas pipeline network coverage coal to gas works full coverage.

To promote the implementation of clean energy projects, Xining City, expand the scope of the ban on coal to 166 square kilometers, and implementation of the "coal to gas" in the natural gas pipeline network range, achieved in the area of ​​coal-fired boiler "cleared." Increase coal trading market will be rectified, completed a five coal market and coal two 49 business outlets, effectively reducing the use of inferior coal pollution on the surrounding environment.

How to use gas-fired boilers can improve the thermal efficiency of the gas boiler is also bad choice will directly affect its thermal efficiency, so we are in the process of buying, be sure to choose good quality. In fact, the factors affecting it improves the thermal efficiency of many, so we regularly thermal conductivity of the gas boiler for cleaning and maintenance, etc., so as to extend its service life. Selection of good thermal and oxidative stability, strong anti-coking. Be careful not to choose odor and color depth of the election furnace. Life with carbon residue, an acid value, flash point, viscosity 4 measure. Make semiannual oil testing, in order to grasp the good quality operation. Identify problems and timely replacement, and find out the reasons and preventive measures in advance deterioration. At the same time it must strictly do not mix different product numbers to use. When used in strict accordance with the rules furnace, to avoid emergency fire heating (temperature rise rate which should be controlled at l0 ~ 40 ℃, h), over-temperature, over-pressure, to take emergency shutdown measures quickly and decisively, always observe the oil level and the oil expansion tank temperature. Such as the lack of oil should be added. Prevent air and water into the oil circulation system. It will accelerate the reaction (the oxidation rate at two-fold increase for each increase in L0 deg.] C temperature) after direct contact with air because of high temperature, high temperature oil to prevent direct contact with air. A better approach is inflated with nitrogen gas to the upper space of the sealed tank. Forming a protective gas layer, sealed under nitrogen unconditionally. To header tank temperature generally does not exceed 60 ℃, header tank is not directly connected in series within the circulatory system. Improve the thermal efficiency of the furnace hot oil boiler, timely removal of the inner wall of the furnace, plate line grime on the walls, in order to ensure good heat transfer, and should use a better quality of gas as far as possible, so that the heat generated by the combustion of coal in time, fully passed to it.

Steam and hot water boiler fueled water level gauge fault safe hydraulic machine operating company of Henan fast boiler with small series to introduce a common steam boiler water gauge Problem safe operation of steam and hot water boiler water gauge failure of hydraulic machine, the causes and solutions approach a hot water boiler steam water gauge reason and common problems: 1, the water level is too low mounting table; 2, water table, even the water pipe is too small; table 3 have low level or a water level indicator, when active, only one only water table; 4, the ground water table, drain cocks no drainage; 5, a drum water level on the table is valid, another water table damage; 6, the tap water gauge screw fixed; 7, the tap water gauge leak, leaking; 8, the performance of the water table level false; 9, the drum water level in the water table irregularities two inconsistent; water gauge glass often broken; 11, water level gauge glass without guard; 12, water gauge low water level glass plate not shown in the red line instructions; 13, glass plate dirty water table, the water level observation is unclear. The main reason is because of 1-4 above design, installation or alteration of dislocation caused. When the steam boiler with a low water table position when the drum is only a case of the water table, water table because the internal balancer lowland leakage short-circuit (at that time can not be detected), resulting in the emergence of lowland water table high water level ( the so-called full of water), and the water table on the drum performance but low water level (or even probably not see the water level), then the fireman because they can not determine the true level of the boiler will go immediately and check the water level in the drum on the table, it will be very serious water shortage in container delays when the boiler accident occurred. Glass-sided water table in front of a glass sheet metal frame box lined with asbestos pad contact surface made of cardboard and then screw the cover frame and the cover pressure closely. Some even show the water level too low trust status of the water table, and take a little sewage, mistakenly steam boiler water when filled with water incident handling, accelerate the production of the accident, there is precedent for such incidents to be investigated. Then, the above-mentioned reasons hinder 5-9 problem occurs mainly boilers lasting not run when washed in water table, not routine maintenance, resulting in water gauge cocks rust, gas, water and even the block, or insufficient packing or aging deterioration. False water level phenomenon, in addition to gas, water or even the cock pipe is blocked, but also could be vapor, the water pipe connected to the water table caused by misalignment connection; steam, water tap handle installed the wrong position resulting cock closed, since there poor water quality, the boiler priming and thrown false water level. Water gauge glass is broken mainly steam, water faucet centerline not aligned, the presence of glass bending stress; long glass without expansion gap; water table is at the window glass is a cold draft, and the glass pipe quality was poor. Safe operation of hydraulic machine 1, hydraulic machine operator must be trained to master the equipment performance and operating techniques to work independently. 2, before the operation, you should clean up various debris on the mold, wipe any dirt hydraulic rod. 3, the mold must be installed hydraulic machine in case of power failure, and prohibit the collision start button, the lever foot on the footswitch. 4, installed on the upper and lower dies, the die gap adjust, unilateral allowed off-center, a good confirmation of the fixed mold pressure again. 5, before the hydraulic machine is first started working apparatus idling 5 minutes while checking whether enough oil tank, pump noise is normal, the hydraulic unit and pipes, fittings, if the piston leakage phenomenon.

Regular maintenance of electric boilerIn general, the electric boiler should be repaired and maintained within 1 ~ 2 years, which is helpful to the normal operation of the electric boiler. For the electric boiler, regular maintenance is also the basic to ensure its normal operation. 1, when maintaining and maintaining the boiler, Must cut off the power supply, must release pressure. 2, burners should be removed from the boiler body every two months, carefully remove carbon deposits and dust and other foreign matter. The photo-electric tube is polished once a month. The fuel filter should always be cleaned and filtered. Carefully clean the inner filter screen of the oil pump and do not destroy the gasket. The burner shall not be idle without oil to prevent damage to the oil pump. 3. The water level gauge shall be kept clean at all times. Open the cleaning valve once a day to keep the water level clear. 4. The safety valve is pulled once a day in case of rust failure. After the work, check if the tools, materials, accessories are complete, to prevent remaining in the furnace and other spaces. Special person delisting, acceptance and acceptance of qualified before leaving the work site, final maintenance records, in order to prepare after the inquiry.