Low Price 10t Natural Gas boiler Industrial Azerbaijan

The Fangkuai Group's unique full-operating low price 10t boiler industrial azerbaijan operation laboratory has an annual operating cost of more than 5 million yuan, which can simulate the operating conditions of various types of boilers under multi-operating environment conditions. The laboratory provides technical tests such as test and inspection, analysis and evaluation, data evaluation, energy saving and environmental protection, and special software from materials to complete equipment, hardware to software, and even complex large systems.

The difference between ordinary and low nitrogen low price 10t boiler industrial azerbaijan boiler:? With vigorously promote environmental protection department of China's low-nitrogen boiler being applied more and more common. In the eyes of many low nitrogen boiler just meet environmental protection to reduce emissions, but in reality not. The following describes a low nitrogen boiler manufacturers to distinguish the conventional type boiler and low boiler nitrogen for everyone? A difference in emissions due to the different combustion grate firing, combustion chamber, circulating fluidized bed boiler, the furnace of different structure, but also its original NOx emissions when large differences, in general, not specifically for low NOX combustion furnace using technology, circulating fluidized bed original low NOx emissions, NOx raw emission Stoker furnace represented by a chain slightly lower, industrial pulverized coal boiler as burning boiler room, the higher the NOx emissions original, well-known domestic boilers have low nitrogen emissions is greatly reduced. Second, different boiler technology, layer combustion, combustion chamber, circulating fluidized bed boiler may be different with different low NOx combustion technique in accordance with the combustion mode, the combustion boiler for the air distribution layers using an air classifier, and more often to achieve low flue gas recirculation nitrogen combustion; under the influence of a typical flue gas recirculation combustion boiler combustion zone layer, in conjunction with the air fractionation techniques for reducing NOx by catalytic char; super reduction furnace denitration technology in recent years, new furnace denitration techniques, by position reasonable combustion flame spray region ammonia, direct denitration at a high temperature flame. Low Nitrogen mainly the secondary air boiler, the coal to the location and distribution of optimal adjustment of the mouth, or the like to increase the flue gas recirculation system. Third, different security, the center layer after combustion, combustion chamber, low-NOx combustion furnace circulating fluidized bed boiler technology a large number of tests performed, it has been verified in engineering applications, in general, a low nitrogen boiler, security to be higher, the reason for its sales in recent years more and more, there are many users because of its high security, a threat to the space environment small purchase, which is one of its important differences with ordinary boilers.

Primary air tube blockage is what causes? How to prevent? Reason: 1) blocked or coked-burner fire nozzle inlet is blocked portion of small oil gun and other debris. 2) too many impurities coal, powder machine speed is too high, the pulverized coal and primary air speed too low. 3) powder machine speed is too high, too much under the powder without timely blown away. 4) a low pressure (throttle open or not to open too small), can not take away meal. Precautions: 1) to the powder and the rotational speed of the unit load and adjust relevant primary pressure according to the powder not more than 700 rpm rotation speed, a wind speed of each holding 25 ~ 30m / s, the mixed primary air temperature was controlled at 180 to 250 ℃, a pressure depending on the load, depending on coal, in the range 2.5 ~ 3.8kPa. 2) find a wind speed is too low, the primary air temperature is lower than the normal value should be to lower the rotation speed corresponding to the normal to the powder of a primary air temperature and wind speed. 3) open, gas steam low price 10t boiler industrial azerbaijan tank should be fully cut-off torch powder, the powder in the tube is blown accumulated powder. 4) Fire mouth clogged or coked should try to remove. What causes large vibrations induced draft fan? 1) motor bearings in oil, resulting in large vibration and bearing wear; 2) even when the shaft is mounted on the center not good; 3) induced draft fan stall surge; 4) anchor bolt loosening induced draft fan; 5) blade fouling or wear ,lost balance.

Damage to the performance of the reheater 1, a low price 10t boiler industrial azerbaijan leak alarm device audible signal; abnormal sound near 2, reheater, serious damage to the furnace clearly audible sound; 3, reheater pressure drop electric load; 4, the chamber pressure rises too vanes Yin automatic opening air tight large current rise induced draft fan; 5, damage to the tobacco-side temperature decreases, both flue gas temperature deviation increases.