gas fired steam boiler manufacturer in mau

SUMMARY gas fired steam boiler manufacturer in mau maintenance gas boiler twice monthly maintenance inspection item A. Fuel supply line: a filter cleaning gas oil; ignition gas conduit 2 airtightness inspection; 3 checks whether the flow line... B. inspection of the instrument: a flushing water table; 2 Syphons flushing; valve experiment. C. Check burner:.... The flame detector (photocell) cleaning the light receiving surface; second inspection oil pump pressure is normal; 3 checks the combustion flame is normal; 4 check burner, the burner sound is abnormal; 5 Cleaning revolutions cup; 6 o'clock washing water rod. . Check D. Intake system: a washing water filter; 2 reaches rated pump head and flow; 3 a check valve is working properly... E. daily drainage tank and the cleaning debris. Water quality testing, water testing furnace. F. Check the combustion consumption is normal. Every three months in addition to the maintenance items plus the inspection item inspection items: Electric Part A: 1 line is loose aging, failure; 2 check the reliability of electrical components, overload; Protection relay 3 is normal; B.... open soft low deactivation tank valve exclude sludge; C to test the boiler and then point interlocking means: 1. low water position; overpressure 2; 3 flameout 4. The exhaust gas temperature ultrahigh; D. et quality tobacco. detection: analysis of tobacco smoke constituents comprising temperature detecting tail, combustion is working properly checked. E. burner and boiler cleaning outer cleaning. Paul A. large projects each year hosts a body part of a comprehensive clean-up tobacco pipes, water pipes, front and rear smoke box, part of the furnace and the burnout chamber and smoke tubes ash collection. 1. inspection openings comprehensive inspection hole hand hole, manhole sealing soundness, and timely replacement of defective seals. 2. The overall comprehensive testing instruments, valves, comprising detecting pressure gauge and safety valve, the pressure controller and the electrode level controller tuning. Part B. burner: Burner cleaning turn round cup, ignition means, filter, pump, motor and impeller systems, throttle link means to add a lubricant. Re-awarded for combustion testing. C. access control section detecting electrical components, control lines, the control box clean ash collection, each control point is detected. D. water supply system maintenance water treatment plant to check whether water quality standards, a comprehensive clean soft water tank, to check the functioning of the pump and lift, clean check valve spool and so on.

For more than two decades, it has been the focus on clean boilers, the insistence on precision and wisdom, and the pursuit of exquisite craftsmanship that have made today's Fangkuai boilers. Fangkui Boiler will always be based on the boiler industry, and will return customer support and trust with brilliant results and sophisticated technology.

The preparation you need to do before the boiler is installed

The boiler is a device that supplies steam and hot water for industrial production or daily life. After the company purchases the boiler model, it needs to consider the installation problem. The installation of the boiler is directly related to the important steps of the smooth operation of the boiler, except for the installation of the auxiliary machine. Also need to pay attention to the preparation before installation.

1. Handling the registration of natural gas boiler installation: According to the “Safety Supervision Regulations for Steam Boilers”, the units that use the boilers should go through the registration procedures one by one. The boiler use unit shall have a person responsible for the boiler installation work, responsible for contacting the local boiler supervision agency and filling out the installation notice. When the boiler is installed, it must be attended by a furnace, and it is equipped with a pipeman, a fitter, a hoist, a cold workman, an electric welder and an auxiliary worker.

2. Determine the installation location and qualification of the boiler to determine the installation location. The boiler installation unit must have a boiler installation qualification certificate issued by the superior authority in accordance with the installation scope.

3. Inspection of boilers and accessories: Before the installation of natural gas boilers, the boiler body, combustion equipment, components, natural gas boiler auxiliary machines and accessories shall be inspected and accepted according to the drawings, and records shall be made. If it is found that the relevant standards are not met, it shall be promptly submitted to the factory. .

fossil fuel power plant boiler

A fossil fuel power station boiler is an energy conversion device that uses high temperature flue gas generated by chemical energy released by fossil fuel combustion to produce steam. The steam produced by the boiler will be used to generate electricity. In fossil fuel power station, steam boilers produce large quantities of steam at high temperatures and pressures. This steam is used in steam turbines to generate electric power. The steam generating unit is thus a major component of a thermal power plant.