10t Natural Gas steam boiler Fully Automatic Nepal

After the gas hot water boiler hot water boiler vaporization emergency 1. Vaporization handler circulating pump stops abnormally pump failure caused by: ① blower stops running immediately. ② immediately open the door, take measures to pressure the fire, lift the chute gate, cutting off the supply of coal grate. ③ In the case of boiler pressure not greater than 0.6MPa (600KPa), the exhaust valve to follow, only a sharp rise in pressure in the boiler deflated, used only relief exceeds 0.9MPa, and the exhaust process to be carried out slowly, prevention boiler due to loss of pressure and more violently again vaporized. ④ close the boiler water, water main gas valve. ⑤ open stop valve recirculation line, to ensure that the water supply pipe velocity convection heating surface (economizer) to prevent re-vaporization of the economizer. ⑥ The operation of the above operation, at the same time to pay the boiler to reduce the boiler water temperature and the furnace pressure. ⑦ After the boiler pressure is normal, i.e., opening the standby circulating pump, into the normal combustion. 2. Treatment failure or sudden loss of power boiler vaporization of power: ① immediately open the door, lift the coal chute slide gate to take pressure fire measures to reduce the oven temperature. ② Grate with the fastest speed in order in the shortest time to fire onto the slag tap. ③ the degree of treatment in the first case. Once a short time can not supply heating network system, antifreeze should take emergency measures. 3. Due to excessive heat boiler boiler vaporization process: ① the immediate closure of the drum, induced draft fan. ② immediately open the door, take measures to pressure the fire, lift the supply of coal chute slide gate, off of coal, while the grate into fast gear. ③ In the case confirmed the presence of water, the boiler can supply water to the boiler body, boiler out of the water while closing the main valve. ④ Open line stop valve recirculation pump to ensure water velocity convection heating surface of the pipe, to prevent the economizer again vaporized. ⑤ Open circulating pump with jog mode, jog each time less than 30 seconds, again less than one minute jog interval. Jog purpose is to reduce the boiler water temperature, while preventing a large amount of steam into the pipeline system. ⑥ back into place after the safety valve, circulating pump running, and then the normal burning stove. 4. Water boiler system run vaporization process due to water loss, loss of pressure caused by: ① immediately closed drum, induced draft fan. ② out of the water while closing the main valve and the boiler circulating pump. ③ take the same measures to cool the furnace tube described above. ④ Open stop valve recirculation line. ⑤ rely exhaust valve until the safety valve back into place. ⑥ until the boiler water temperature drops below 50 ℃, when the temperature of the furnace temperature less number 200 ℃, again within the boiler feed water, water course to be carried out slowly, to prevent harm to the boiler when the temperature is too large. ⑦ After processing leakage fault, the system time to the replenishment, and out of the water boiler always open the valve, and the circulating pump, and then normal combustion.

Our company attaches great importance to the quality of wine, winemaking process steam requirements provided very strict, party fast boiler provides fully meet our needs, give us a brewery to provide strong support. --customer feedback

What if there is wear and tear in the natural gas boiler? Detailed inspection is the key, as is fuel management. According to the operation condition and time of natural gas boiler, we can plan reasonable wear inspection. When using fuel, we strictly control the granularity of coal and limestone. The size of bed material should be strictly controlled. Boiler waste should be disposed of. The waste residue of the boiler must be treated before it can be discharged. Natural gas boilers should be installed where heat is used, easy to install. The hot pipe should not be too long. It should have a good insulation. The pipe shall be tilted properly from the hot water outlet to the end. The water supply source shall be equipped with a control valve. To discharge exhaust gases, the chimney of the natural gas boiler should extend to the outside and the outlet should be 1.5 to 2M higher than that of the boiler. If we want to reduce the influence on the water wall tube, we can adjust the air pressure and air volume properly, and effectively reduce the wear of the water wall. Check time is usually standby or downtime. Items to be examined include wall wear, furnace sealing and smoke leakage. In case of wear and tear, repair and welding are required to ensure the normal operation of 10t steam boiler fully automatic nepal. Generally speaking, before combustion of natural gas boilers, fossil fuels, fossil fuels and bed and circulating materials should be filled in the combustion chamber at wind speed and strength. And stiffness of the air convection under full integration. Furnace bottom air device, inner core area upward. The movement in the outer ring region flows downwards along the water wall of the furnace, thus prolonging the residence time of the coal particles in the furnace. Mineral particles, a large number of ash powder and smoke contain a large number of fly ash particles, these continue to lead to rapid wear of water-cooled wall tube, make wall thickness wear thin, resulting in wear.

Vertical 10t steam boiler fully automatic nepal What are the advantages? With the continuous development and progress of science and technology, the boiler applications also become increasingly wide range of vertical steam boiler is not only elegant appearance, small footprint, and low power consumption, strong performance advantage. So what are the advantages of low power consumption vertical steam boiler what else? Let us to understand a small taping, convenient vertical steam boiler ignition bathing water can be discharged outwardly after two minutes a suitable temperature, without pressure, safety, a normally open tube furnace to the atmosphere, does not have any valves, to ensure safe and reliable operation. And interior of the boiler can be extracted within a few minutes, making repairs or updating the boiler is also extremely fast, short, very convenient. Second, clean the inside of the boiler fouling is a killer, many products are not remove fouling or in addition to science is not complete, but the vertical steam boiler manually to complete the removal of internal boiler fouling, will not leave any dead ends. And heating water and bathing water is not mixed with, but also add a water softener water heating cycle intervention, will not make the whole boiler fouling, very clean. Third, energy saving vertical steam boiler when the water temperature of the furnace is low, reduces the heat loss. And the use of advanced environmental protection technology, can completely smoke-free dust-free, high environmental requirements for cities to achieve energy saving effect. During use, does not produce smoke, the onset of gas boilers together as a whole, the fuel on the grate in cast from the incineration stoker opening, using a high temperature steam and coal seam combined and allowed plenty of chemical attack the combustible gas after reaction, multiple backhaul several cycles, using the pipeline full heating surface, the progress of burning thermal efficiency, heat loss can be reduced to a large extent, energy saving. Vertical steam boiler since the sale of the trust of many old and new customers praise the majority of users. Simple vertical steam boiler maintenance is also very simple, and most businesses will be responsible for after-sales maintenance boiler work, professional service staff, so please do not worry, you can rest assured purchase!