supply water oil boilers

Steam Boiler Types for Sale

ZG Boiler is the steam boiler manufacturer in China, and it supplies industrial steam boiler & hot water boiler to customers. ZG boiler mainly supplies steam boiler to food industry, and they includes coal fired steam boiler, oil & gas fired steam boiler, biomass fired steam boiler, waste heat steam boiler, CFB steam boiler. And the oil & gas fired steam boiler and the coal fired steam boiler is widely used in food industry. That are ideal for human which has high efficiency, low emissions, reliability and low maintenance. The fuels are mainly coal, oil, natural gas, light oil, heavy oil, and other fossil fuels.

What are the precautions in the loading and installation of gas-fired steam boilers?

Gas-fired steam boilers are a very wide range of special equipments, widely used in food, chemical, paper, textile, construction and other industries. In the process of loading and installing a gas steam boiler, some problems must be paid attention, otherwise it may cause a certain degree of economic loss.

1. Pay attention to the following matters during the loading and unloading and handling of gas-fired boilers: the lifting capacity of the lifting equipment should match the weight of the lifting boiler. The lifting lug on the boiler with the lifting lugs that cannot be used for lifting can not be used for lifting. The length of the steel cord should be reasonably selected to avoid the scratching of the furnace due to the improper length of the steel cord. The boiler must be protected from any damage during handling and handling.

2. Reserves for maintenance space When installing boilers, ensure that there is sufficient maintenance space around the boiler.

3. Setting and precautions for the base and base of the gas steam boiler The boiler body must be installed on the basis of 100-150mm above the floor of the boiler room. It must be confirmed with the technical personnel of the boiler manufacturing company in advance and constructed according to the basic drawings. The anchor bolts must be reserved on the foundation. The foundation shall be capable of withstanding the maximum weight of the boiler and the amount of water it holds. When installing the base, you must first position it. After positioning, adjust to the same length of the two diagonals of the base, and then tighten all the fixing bolts. The installation of the base is carried out with reference to the reference line.

4, general precautions Be careful not to tilt and impact the boiler and accessories too much. No combustibles can be placed around the boiler. Do not use oil and water to smother the boiler. The boiler should normally be installed in a separate boiler room. The new gas-fired boiler room should not be connected to the house. The boiler room shall not be connected to Class A, Class B and Category C fire hazard rooms using flammable liquids. If connected to other production plants, the application firewall is separated.

5. The fire resistance grade and fire protection requirements of the boiler house building shall comply with the requirements of the Code for Fire Protection of Building Design and the Code for Fire Protection Design of High-rise Civil Buildings. The ground of the gas steam boiler room should be flat, non-flammable, no water accumulation, and the foundation load should meet the requirements. The power supply voltage of the gas steam boiler room should be stable to avoid causing the electrical components to burn out. If the voltage is unstable, it is recommended to install a voltage regulator. Ventilation equipment should be installed in the boiler room, and the boiler should be kept at room temperature below 50 °.

Industrial boilers is a major driving force for social development, but also brought great pressure on the environment. Whether coal-fired boilers, biomass boilers, or, when the supply of energy, the emission of pollutants will soot and nitrogen oxides. Some enterprises in order to save costs, the pursuit of more profits, but also allowed to change the fuel, biomass boilers burning coal steal, wood, and even garbage doping or other industrial waste, produce dioxins and other carcinogens directly into the atmosphere after combustion, pushing PM2.5 concentrations.

Since started Blue Sky Battle horn Guangdong Province, many cities have begun to respond positively, Dongguan City, is one of them. Atmospheric do in-depth business thoroughly, and the development of industrial boilers business accounting, confirming the city's need to eliminate highly polluting boilers have 765 units, of which 728 sets of biomass boilers, 37 coal-fired boilers. Subsequently, promote the transformation of facilities operations out of high pollution boilers within the city.

As of May 14, 2019, the city's 324 enterprises active removal of 363 coal-fired boilers burning biomass, as well as 83 to 84 companies demolition of the old boiler pipes, 447 completed phase-out plan of the boiler in advance.

Although there are many companies take the initiative to carry the main responsibility for the ecological environment, but there are still some chances enterprise.

Atmospheric Office official admitted that "in the daily inspection, the company found that some still illegal use of boilers, perfunctory 'coal to gas' work." Among them, although some enterprises written off coal, biomass fired boilers, but because of natural gas boiler installation behind schedule, forced production needs, but to let the old boiler continues posts. There are companies more "capricious", install two-way pipeline for new and old boilers, strict supervision when using gas-fired, law enforcement officers continue to take a coal burning biomass. There are even companies deliberately delayed "from coal to gas," progress, choose to enable the original write-off of the boiler.

This year, the Office of Atmospheric inspection personnel to go to 244 companies in the field to check the boiler usage, found that 42 enterprises there is illegal use of boiler problems. Among them, there are 18 companies of illegal use of biomass boilers has been canceled. "Not only pollute the atmosphere, there are still significant safety risks." Atmospheric Office inspection personnel Lurui Quan said, "the city's coal-fired, burning biomass boilers as well as 113 units, involving 94 companies, is expected to complete phase-out year, access to clean energy. "simple behind the data, there is a thick ledger out of the transformation of the boiler," when removed, when write-off, out of a pin number one glance. "

Atmospheric Office official also said the recent city towns Street (Park) Atmospheric Office will carry out investigation and remediation special action has been canceled boiler, supervise and guide enterprises to demolish the old boilers and pipes, put an end to "note not sell" phenomenon. At the same time, urge enterprises will have been dismantled boiler dedicated to the sale of scrap recycling company, effective way to solve the old boiler, complete eradication of pollution and safety hazards.

With this knowledge points, easily handle common fault boiler pump gas boiler pump is an important equipment, mainly for replenishment aspects boiler. Once the water pump fails, will first trigger replenishment system abnormalities, then water level gauge, pressure gauge, valve instrument will throughout the spate of error, and thus lead to serious boiler accidents. We have compiled the boiler pump five common faults; mastered them, to help you easily cope with pump failure. A lack of flow causes: Effect of multiple pump flow is insufficient suction pipe leakage, valve leakage bottom; inlet plug; insufficient depth of the bottom valve into the water; the water pump speed is too low; sealing ring or excessive wear of the impeller; and other highly absorbent excessive . Solution: Check the suction pipe with the bottom valve, blocking the leakage source; clean mud inlet at the outlet or plug; end of the valve must be greater than the depth of the water inlet pipe 1.5 times the diameter, to increase the depth of the bottom valve into water; check the power supply voltage, increase pump speed, replace the seal ring or impeller; reduce the installation position of the pump, or the replacement of the high lift pump. Second, causes excessive power consumption: pump speed is too high; the pump shaft bending or misalignment of the spindle motor or pump shaft and not parallel; inappropriate selection of the pump head; pump suction sediment or obstructions; motor ball bearing damage. Processing Method: check circuit voltage, reducing the pump speed; correct or adjust the relative position of the pump shaft and the pump motor; with a suitable pump head; or clean sediment blockage; three ball bearings replace the motor, pump noise or rattling Cause: pump installation is not strong or high pump installation; motor ball bearing damage; pump shaft and the motor shaft bending or misalignment, and the like are not parallel. Approach: install stable pumps or pump with reduced height; replace motor ball; correction bent pump shaft or adjust the relative position of the pump and motor. Fourth, the motor shaft, or bearing overheating causes: lack of lubrication or bearing rupture. Approach: filling oil or replacement. V. No water causes: pump and suction tube not filled with water; level below the pump filter tube; suction tube rupture. Processing Method: negative end of valve failure, filled with water; reduce the installation position of the pump, so that water drainage pipe under the action, or the like movable liter water filter and then pumping water; the suction pipe repair or replacement