High Efficiency Distributor hot water boiler 4t Azerbaijan

Thirteen Five release plan indicates that China's move towards green development pace firmer, Beijing SASAC Building Materials Service Center from its start, the use of green boiler heating for low nitrogen as the primary task before the onset of winter. SAC Building Materials authorities after preliminary investigation and after the screening, the other fast boiler R & D experience in the field of boiler cleaning two decades expressed appreciation can, in August 2017 signed a five Thalia T6 series one boiler and two vacuum with fast Boiler condensing gas boiler products contract.

SZS series of horizontal boiler are design by double drum, longitudinal type, full water pipe structure. It is consist of the upper and lower drum, convection bank and the left and right set of boxes. The total size are close-knit, and the external appearance is elegant and beautiful. It apply to com-bust under slightly negative pressure because the water screen of the horizontal boiler furnace is use of close-packed structure with perfect tightness.

Boiler operation, the pressure gauge must constantly monitor the value of maintaining a stable water pressure. Boiler water circulation pressure change was observed, reflects the relationship between the temperature of the boiler water and steam consumption. Boiler operation, when the steam pressure is automatically adjusted, fireman personnel primarily to monitor whether the system automatically adjusts the sensitivity so that, identify problems promptly resolved, the automatic control system to ensure that sensitive and reliable.

Flue gas fuel boiler design requirements 1) to be straight flue, air tightness, attachment and less resistance is small, the level of 1% or more to maintain the flue rise should be disposed laying down slope disposed avoided. 2) the fuel gas flue and the chimney of the boiler should be of steel or reinforced concrete construction, the lowest point of the flue and the chimney should be water-seal disposed condensate drains. 3) thickness of the metal plate is generally used flue 4 ~ 6mm, the flue design, should be sufficient arranged reinforcing ribs to ensure the strength and stiffness requirements. 4) thermal expansion of the flue should be compensated, the compensation amount to be calculated and the correct selection. 5) steel flue and reliable insulation measures should be fixed. 6) a fuel gas boiler should correspond to a chimney boiler, when the boiler by the conditions required to share a chimney flue or several, each boiler should be ventilated suction force balance. 7) arranged in a flue provided when necessary thermal and environmental measuring point measuring point in place. Single rated evaporation amount is equal to 20t / h or single thermal rating of greater than or equal 14MW oil-fired boiler, a fixed continuous monitoring smoke flue gas must be installed. S02 emission concentration of the instrument. 8) Where the flue gas is easy to assemble, and when more than one boiler or a total share a chimney flue shall be fitted with explosion-proof door on the flue after each fuel gas-fired boiler, the location of the vent should be conducive to relief, should be provided without jeopardizing personnel safety and proper position before turning, when explosive gas may endanger the safety of the operator, should be installed on the guide tube explosion relief means. 9) For some of the longer flue boiler room, they should be accounted for resistance, select the corresponding drum, induced draft fan (ID fan when there), in order to ensure the smooth flow of exhaust. 10) should be considered appropriate chimney anti-corrosion measures, chimney flue gas outlet temperature is preferably above the dew point of the flue gas temperature of 15 deg.] C; when the exhaust gas temperature is lower than the dew point temperature of flue gas, the flue gas should take effective measures to prevent the intrusion.