January 16, Harbin Municipal Environmental Protection Bureau Director of the atmosphere and noise pollution control at the public hall, Li Bin, said: "Harbin problem-oriented, focused on solving the coal pollution environmental air quality, autumn and winter of straw burning pollution." By a wide range of governance, 2018, Harbin has made in terms of ambient air quality improvement remarkable results, the standard number of days 310 days, an increase of 40 days, for the introduction of new environmental quality standards since the best of the year.

Prior to 2017, the total removal of Harbin urban built-up area of ​​small boilers range of nearly 3,000. 2017, Harbin started the largest in the history of the elimination of small-scale boilers battle, tear down 9 district built-up areas and industrial parks within a small boiler 2074 units. 2018, further expanded the phase-out range, expanded from 9 Zone has outside built-up areas, where the built-up area in District 9 out of 10 tons of steam per hour of coal-fired boilers to achieve foundation "clear" on the hour and eliminated more than 10 tons of steam coal-fired boilers 99 units, out of the city a total of 1191 units. The results accumulated over the years, significantly reducing the use of coal, reduce emissions of pollutants.

According to reports, in the fall and winter seasons, Harbin straw Jinshao pay close attention to the work to implement the five grids responsibility, building straw Jinshao 24-hour duty system inspections, inspection teams at all levels of uninterrupted inspection. In addition, Harbin has also implemented emission standards of air pollutants, vehicle control, open-air barbecue ban, dust management, especially in heavy weather pollution contingency timely warning, take active control measures played a role in the down-clipping. Through various management, air quality has been greatly improved.

1, the safety valve should be mounted vertically in a high position in the pot business, set box.

2, between the safety valve and the drum or header, not equipped with access to the steam outlet pipe and the valve.

3, the lever-type safety valve should prevent movement of the self-apparatus and the weight limit leverage deviant guide tube, a spring safety valve should lift and handle means for preventing movement of the adjustment screw is screwed lightly.

4, the rated steam pressure less than or equal to 3.82MPa gas steam boiler safety valve throat diameter of not less than 25mm; power greater than the rated steam pressure 3.82MPa boiler safety valve throat diameter not less than 20mm.

5, the safety valve and coal-fired steam boiler tubes, the cross-sectional area not less than the cross-sectional area of ​​the valve inlet. If several valves installed together with a short tube directly connected to the drum, the cross-sectional area of ​​the passage should not step short tube to 1.25 times the area of ​​all the exhaust valve.

6, the safety valve should normally be installed exhaust pipe, exhaust pipe should be through a safe place, and there is sufficient cross-sectional area to ensure the smooth flow of exhaust.

7, the safety valve exhaust pipe at the bottom should have received a place of safety posturing of drainage pipe, the exhaust pipe and drainage pipe not allow the installation of the valve.

8, rated evaporation to 0.5t h coal-fired steam boiler /, at least two safety valves installed; Rated evaporation 0.5t h less than or equal to electric boiler /, mounted on at least a safety valve.

Problematic fired 4t boiler automatic vietnam (1) Henan small boiler gas boiler should be noted, by the Henan coal into gas boiler, i.e. the original becomes a negative pressure is now slightly positive pressure combustion burner, the furnace must be noted that the structure and the sealing wall problem; (2) prevent explosion of the furnace, a gas fired boiler furnace to Henan, when defective or incomplete combustion of fuel atomization gas in the furnace or heating surface of the end aggregate, fire or explosion occurs, and therefore, in appropriate sites shall boiler explosion vent means, while the control program should be added to the ignition and flame protection device of automatic control, to ensure safe operation of the boiler; (3) the selection and arrangement of the burner close to the furnace in the form of, should the flame in the furnace better fullness without forming dead air; adjacent flame of the burner to avoid mutual interference; low load flame holding in the furnace central position, offset from the center of the furnace to avoid the flame center of symmetry; unburned gas-air mixture is not in contact with the heated surface , to avoid the formation of incomplete combustion gases; hot flame to avoid high-speed heating surface erosion, in order to avoid excessive heating surface so that the wall strength of overheating. Burner arrangement also consider the gas pipe and duct arrangement, easy to operate, inspection and maintenance; (4) Mechanized layered coal-fired boiler, gas boiler to change Henan, first removing its longitudinal arch, taking into account the increase in the bottom heating surface to replace the grate, grate to prevent overheating burn; (5) gas velocity Henan convection heating surface is not limited by the gas boiler ash abrasion conditions, gas velocity can be increased properly, so the convection heat transfer heating surface coefficient increases, without increasing the heating surface of the boiler, can increase the pressure of the boiler, steam-water separation capability should be noted that at this time means the pot to ensure the quality of steam, hot air for the boiler had particularly important.