Price Natural Gas steam boiler Industrial Myanmar

Boiler precipitator technical principles of environmental protection and the development trend in recent years, the rapid development of gas power plant boiler in the direction of large-capacity, high-parameter, either manufacturing or operations management have been close to the advanced level. Boiler and gas industry to maintain large, widely distributed, high energy consumption, heavy pollution, energy efficiency and pollution control the overall level compared with foreign countries have a certain gap, a huge energy saving potential. By the end of 2012, China's use of gas in industrial boilers 467 000 units, with a total capacity of 1.78 million tons of steam, the annual consumption of about 700 million tons of coal, accounting for over 18% of the country's total coal consumption. China's gas lower overall energy efficiency of industrial boilers, about 15 percent of its actual operating efficiency lower than the international advanced level, with great potential for energy savings. In recent years the rapid development of technology the dust bag, in particular accessory bag filter (dust bag, dust bag cage pulse valve, control of the PLC technology, etc.) to improve quickly, while baghouse 10% desulfurization efficiency can be improved It is dry boiler flue gas desulfurization one of the major thermal power plant equipment. Boiler precipitator dust is the most effective pollution control equipment. It has a high dust removal efficiency, after the flue gas-containing filter baghouse dust concentrations below 50mg / m3, even at 10mg / m3 or less, and can efficiently remove the fine dust particles. Boiler boiler precipitator not just in the production of which use can also be used in other fields of thermal power. During use of the boiler generating the flue gas and dust is inevitable, the boiler boiler precipitator dust is separated out from the flue gas, thus reducing the dust pollution and facilitate further flue gas desulfurization, denitrification process. Spark arrestor smoke dust is mainly used in some high temperature and flue gas containing process Mars. For example, the flue gas cupola, intermediate frequency furnace flue gas, a furnace flue gas and so on. The main role is to eliminate smoke sparks, to avoid burning dust bag. Spark arrestor has a variety of structural forms, cyclone, louvered like. The most effective way of collecting cyclone is, the guide vanes guide the flue gas using a cyclone-type rotational flow, after the dust and large particles Mars cylindrical guide vane duct wall collision or off. When the smelting furnace flue gas containing spark large particles, dust bag will cause damage. Mars trap can effectively trap particles Mars in the flue gas, the protection of the bag filter. The entire device by the PLC control unit, automatic cleaning, discharging and automatic temperature control and over-temperature announcer.

Recently, the Guangzhou City issued an action "Guangzhou 2018 annual work plan for comprehensive prevention and control of air pollution," the bureau of law enforcement to monitor the detachment on August 28 = 29 organizations launched a special enforcement action against a biomass boiler.

The special enforcement action by the municipal and district levels of environmental protection departments jointly launched, deployed Yuexiu, Tianhe, Haizhu, Huangpu, Conghua five district environmental protection law enforcement backbone, with the Guangzhou City Environmental Protection law enforcement inspection detachment composed of 18 cross-law enforcement group, to increase the city all registration to carry out quality checks of 125 biomass boilers in the book, focus on examination of Guangzhou boiler emissions monitoring system in Zengcheng District registered the existence of complex biomass boilers coal or other high-polluting fuels, whether there are special furnace and supporting bag dust removal facilities, whether the normal operation of the boiler control facilities, whether discharge standards as required entry and update Guangzhou boiler emission monitoring system and other issues.

After verification, the registration system by the city list in the boiler has been disabled (off or relocated) boiler station 43, not included in the other eight found regulatory list table 133 actually inspected. Among them, 28 units involving suspected violations accounted for in the boiler problem with the boiler (90 units) ratio of 31%, the problem of coal-fired boilers in complex 2, the resurgence of firewood, 11, allegedly did not apply for environmental protection procedures, waste gas treatment is not installed facility or facilities are not the normal use and other illegal activities 15. For complex high-polluting coal and wood fuel boiler according to law-site seizure and transfer penalties and territorial environmental protection departments to follow up treatment in accordance with the relevant provisions of Article 107 of the "People's Republic of China Air Pollution Prevention Law." The rest were arrested for illegal transfer of territorial environmental protection departments for investigation.

Oil-fired boiler safety instructions oil-fired boiler is one of many hot water boiler to one of how to prevent boiler fuel boiler appears to be abnormal use it? First, to ensure the normal operation of the fuel in the boiler feed water quality and quality of qualified soda, to reduce the water wall tube fouling and corrosion, strengthen supervision and boiler water boiler water when found unqualified, should increase the number of times a given row; while the flue gas flow rate control , especially when the flue gas velocity in the corridor, during installation and servicing, should minimize the distance between the wall and the superheater tubes, while the distance between the tubes to uniformly as possible. second, the fuel boost heating boiler carried out in strict accordance with procedures, control the speed boost. were lower header sewage water wall work required to build the water cycle as soon as possible, promptly switched the gun to ensure uniform heating surface is heated to eliminate half of combustion, eliminating thermal excursions. third, do a good job adjusting fuel combustion boiler, the flame deflection preventing, controlling coal fineness noted that, with a reasonable air to prevent coking, reduces thermal excursions, to prevent the tail reburning fuel boiler; boiler steam parameters be closely monitored, and the main indicators of the amount of water evaporation and the like, to prevent pressure Release, full of water, water accident. fourth, strengthening sootblower sootblower and management, serious fouling preventing heating surface, when there is found furnace coking phenomenon, should be increased blowing Gray times, ensuring good water wall heat sink; overheating problem of the presence of long-term heating surface, installation of thermal supervision controlling temperature measuring points; expansion to ensure accurate indication means using oil-fired boiler units must be fully taken into account the safety problems. in the inspection process must be meticulous in place. to ensure the personal safety of the unit.

Methods of operation and precautions gas price steam boiler industrial myanmar steam boiler with a gas advantage of social development is increasingly clear that the future economic level to enhance people will focus on comfort. Throughout the heating market innovation Although several decades of history in the worldwide gas boiler, but because of China's housing form, heating the environment and foreign difference is relatively large, there is currently in use gas boiler, there are still some unresolved issues The problem. Gas-fired boiler during use, the pipeline can be said is essential. Gas-fired steam boiler pipeline system is necessary to ensure normal supply of natural gas equipment, must pay attention to anti-corrosion of boiler tubes gas. Pipeline gas boiler heating system after a long period of use, will gradually varying levels of wear and degradation slowly, then the gas boiler pipeline corrosion problems which need to pay attention to it? Gas steam boiler heating pipe residual soldering flux has not been removed leaving a clean and cause corrosion in the water system, these regions are more easily aggravated rust corrosion, a long time would cause a pinhole on the heat sink, resulting in leakage. Some flux comprising an organic acid, bis more metals together form electrolytic corrosion effect. The most common heating systems made of stainless steel and iron materials with copper, galvanic corrosion occurs between the iron and copper, in which case, the corrosion rate of steel will be faster than the copper. Since the gas boiler system design, such as a bad selection pump, or the position of the obturator when the bad systems are not very good, the external negative pressure will pump air into the system, so that oxygen in the air system to accelerate corrosion of metal. Will have a good ability to maintain self-neutral water quality, but when the water quality is not good, there are a lot of home electric boiler condensing heat exchanger made of aluminum materials, aluminum is due to the appearance of easily forming a dense aluminum oxide protective film this layer of oxide film can easily be removed by acidic or basic water, resulting in occurrence of corrosion. The metal heating apparatus of the system generated during cutting, the whole or partial etching adhesive residue bonded pipe, as well as some mineral oils, residual casting sand and radiator systems of microorganisms in the system will be increased.