1 tph biogas fired steam boiler

Why should the heating surface of boiler soot-blowing? A: soot-blowing is to keep the heating surface cleaning. Due to the small thermal conductivity ash, boiler heating surface fouling, affect the heat transfer of the heating surface, the temperature of the endothermic working fluid drops, the exhaust gas temperature rises, thereby reducing the thermal efficiency of the boiler; severe fouling, the flue gas flow reduced cross-sectional area, the flow resistance increases, increasing the wind electrical energy consumption, reduce the load of the boiler operation, even forced shutdown; fouling since the rear smoke temperature rise, the tail affect the safe operation of heating surface. Local severe fouling, it is possible to form a "smoke corridor", the local speed increase of smoke due to the heating surface, increased wear. It should periodically heating surface boiler soot blowing.

The use of central heating hot water boiler is the best choice for winter heating in northern China. Shanxi Province is located in Chang Darrow Heating Co., Ltd. mainly provides heating and post-service maintenance of heating equipment, heating clients involved in enterprises and institutions, office buildings, residential housing and a variety of commercial and other entertainment venues. With the wide blue sky covered Battle of the project, China's gradual increase in the proportion of heating for cleaning, heating, Ltd. Dalong Chang respond positively to the call of national policy, high pollution intensity wishing previously used, low thermal efficiency of coal-fired boiler to replace the traditional use hot water boiler clean fuel. After comparing many boiler manufacturers, choosing the optimal selection, determined and professional cooperation parties do fast boiler fuel boiler cleaning equipment. Providing a fast side 35 MW gas tube hot water boiler (SZS35-1.6-Y.Q) according to their actual needs.

First, at this stage, gas boiler water treatment problems 1. boiler water treatment work is inseparable from lack of attention to industrial boiler equipment, but in many of the user site, we found that many boiler operators do not pay attention to the boiler water treatment, sewage and also regularly carry out checks, there is a large degree of danger. The main reason for this phenomenon is harmful to business managers and staff did not realize that not treat boiler water, over time, will produce boiler scaling, corrosion and other problems. 2. boiler water treatment method is not correct in the actual production and living, the boiler is used to contain a wide variety of liquid. But some staff do not know that for different kinds of liquids what action should be taken; some companies using a simple boiler water treatment equipment. These factors can pose a security risk to the boiler, resulting in security incidents. 3. Staff overall quality is not high and some staff members did not follow the rules and regulations of boiler water for testing. In addition, there are a number of operators of professional quality is not high, so that work is not high efficiency boiler water treatment, resulting in the deviation of the test results. There are even some staff members will laboratory data on fraud to fool the upper management.

Electrical installation condensing boilers require all wires to the connector, the connector mounted in the socket. Removed from the receptacle connector without loosening the wire. Located on the back of the monitor connector, to remove the front panel and the boiler connector shields visible. Boiler operation requires a grounded power 230VAC50HZ. When you are working on the boiler, please disconnect the power. Electrical wiring must comply with national or other special local standards. Electrical engineering must be performed by qualified skilled electrical installation engineer. 1, following the line L - 2 neutral and ground connections, wire cross-section of greater than or equal 1.5mm23, any electrical wiring in accordance with the operation of the system of FIG. 4, to ensure reliable grounding boiler 5, and the power supply wire to the principles of the indoor thermostat hot surfaces (outlet line ) 6. If you do not follow the above operation will cause damage to the boiler.