vertical natural gas firetube steam boiler

The wns oil and gas vertical firetube steam boiler produced by zbg is fast assembly installation boiler. And the steam boiler is equipped excellent automatic control burner to realize full automatic performance.

Gas-fired vertical firetube steam boiler and gas steam boiler at any time there is any good compared to the country more and more attention to environmental protection, gas steam boiler has been a great blow, and relatively gas steam boiler by many users of all ages, in recent years, the country also strongly promote the use of gas-fired boiler, gas steam boiler then compared with the gas steam boiler what good is it? And today we work together to explore. Gas-fired steam boiler steam boiler and gas each accounted for half of the market, showing potential rival, but in the long run, gas steam boiler will obviously be the only dominant market. Do not believe, look! 1. Purchase costs: gas boiler is evident in the technical and auxiliary facilities are far ahead of the gas boiler, and it is equipped with a special gas burner. 1 steam boiler tonnage, for example, the price of gas than the gas boiler boiler on high about 30%. 2. Construction costs: The costs mainly from the boiler room. Because the corresponding auxiliary equipment more gas steam boiler, the boiler room in the building have a little more money. The gas boiler auxiliary facilities require little or automatic control and operation, and automatic alarm and automatic protection, not only save building costs, but also safe and reliable; Also connected to the gas pipeline, the burner will automatically supply gas can effectively save costs staff. The gas-fired boilers because of the need of coal on the program, so it needs some staff payroll. 3. Fuel cost: around this by looking at the actual specific fuel price can be clearly seen. The fact is that the amount of gas than the gas burned per hour for much more. 4. environmental costs: in the need to protect the environment, review the current gas boiler more strict. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used.

Process safety valve check valve gas vertical firetube steam boiler is one of the three safety accessories gas steam boiler, when the boiler pressure is too high, the pressure relief valve will automatically exhaust, gas steam boiler is the important safety equipment . The case of a new installation, overhaul, lack of consumer safety valve shutdown and restart more than three consecutive months, have had to re-check safety valve, safety valve to ensure accurate and reliable by the company safety officer, boiler technician, run operators, maintenance personnel together with the completion of the adjustment. Valve adjustment procedure is as follows: 1, the steam boiler when the gas vapor pressure close to the operating pressure of the safety valve, and retest check valve to the air motor exhaust, drainage accident flexibility and reliability of the electric valve, and the panel reinspection situ pressure gauge, the water level of accuracy, such as failure, not allowed to heat the school. 2, ready to call and check the quality of communication tools, a signal indicating whether the good. 3, adjust the safety valves, boiler pressure should be kept stable, pay attention to monitoring gas steam boiler drum level, and maintain normal. 4, steam boiler safety valve to adjust the pressure gauge in place of instructions shall prevail. If necessary using 0.4 or more for the accuracy of the gauge. 5, adjust the safety valve should be carried out only by descending. It should checksum gas steam boiler tuning high pressure safety valve, after the school seizure of the entire set of low pressure relief valve. 6, the following should be in the 0.3MPa, the movement preventing measures must do a good job of setting relatively low pressure steam boiler safety valve safety valve before adjusting. 7, by combustion, and exhaust steam adjust the degree of opening to the air slowly and smoothly up to the required setting pressure. 8, when the gas pressure steam boiler safety valve set pressure to rise if action is normal, then the action and reseating pressure values ​​recorded. If action is not correct or not action should be immediately opened to the air exhaust valve, while the combustion boiler weakened, stop boost, and buck 0.3MPa or less, re-adjust the boiler technician as required by maintenance personnel, until the compliance date. (Lead or lag 0.05MPa action is normal). 9, after the completion valve to adjust gas steam boiler, boiler 0.3MPa or less down to the lifting device and can be installed and fastened to the protective cover, a braking measure required under check valve removal, then Articles 7, 8 verify until all required safety valve calibration check is completed. 10, the safety valve to adjust the gas boiler, check the results recorded in the "safety valve to adjust the recording Visa" within the participants should verify the signatures and Internet safety valve input to the corresponding data in the ledger. During operation gas steam boiler, not only to regularly check on the safety valve, at the same time, we must regularly monitor boiler inspection to ensure that the boiler fully meet the safety requirements!

Exhaust gas has been plagued by sewage paper industry, paper industry pollution problems of the country very seriously. Fujian Heng paper packaging company has been committed to the use of clean-type boiler paper processing. October 22, 2016, David Carse, the paper with my company, signed a 6 tons of steam an integral condensing vertical firetube steam boiler for the production of corrugated cardboard and other paper products. I provided the boiler greatly solve the problem of sewage wastewater Heng paper. After the boiler operation, both to meet local environmental requirements, but also reduce operating costs for the constant boiler paper products.