blast furnace gas steam boilers

Vertical projection which features good blast furnace steam boilers boiler having a vertical steam energy conversion device, the input of thermal energy by chemical, electrical, and high temperature flue gas to the furnace, thereby converted into electrical energy, and to provide the desired life for people heat, on the safety and convenience of all with excellent product qualities, then what good salient features vertical steam boiler has it? 1, reliable safety performance vertical steam boiler in terms of product safety has a lot of protection, by ground fault protection, overvoltage protection and power protection and other measures to make operation of the boiler can always be in a safe state, when the pressure is too low or there is leakage, the boiler will cut off its own power button, so to ensure the life and personal safety of the boiler. 2, the portable vertical steam boiler operation which is preferably used, which have to see ease of operation and convenient operation of the boiler does not require user intervention excessive production process, just to the introduction of the electric power source control box start button to enter the automatic operation state, and when the job if the amount of water in the furnace suddenly reduced, the vertical steam boiler control system is also used to automatically replenish the water in the water tank to fill the pump through the apparatus in order to achieve high efficiency of production operations process. 3, small size and yield stability compared with the conventional boiler products, the type and volume of the vertical steam boilers are an advantage, not only a wide range, and the volume of the boiler is very small, but it has a large steam room to make product productivity and quality are the most significant upgrade in order to obtain a more stable production company that won the biggest profits. The above is a brief introduction which has a prominent characteristic of a good vertical steam boiler, not difficult to find, the boiler reliability in terms of safety and convenience of operation have notable features, but also in the volume and yield stability also has a prominent feature , production efficiency and product quality to make the most significant upgrade, but also to ensure personal safety as well as the effect of the use of the boiler.

It may be suitably improved electrical blast furnace steam boilers burner material: the electric steam boiler at the time of adjusting, if the wind speed control of the secondary is too small, it will lead to too close the gas fire, the burner nozzle so that thermally deformed until failure. Further, when the adjustment is not timely gas boiler load changes the level of the upper orifice of the secondary throttle will be cooled so that the burner is not burning. It may be suitably improved electrical burner of a steam boiler materials, steel materials excellent recommended to choose, and adding wear resistant features. Selection of swirler vanes refractory steel material, so to avoid burning due to swirling vanes configured fall burner opening deformation damage.

50, when arranged inside the boiler room to note a safety distance, the front end of the boiler ready spacing of not less than 2/3 of the length of the furnace, and not less than 2 m; vertical boiler can be shortened; bulk boiler is not less than 4 m and does not affect the blast furnace operation and maintenance. 2, the boiler side and rear channel spacing of not less than 0.8 m, and should meet the operational and maintenance (such as replacement tube bundle cleaning, stirring the fire, etc.) requirements. 3, the top horizontal boiler headroom not less than 2 m; vertical boiler top clearance height to facilitate the operation and maintenance; headroom boiler room the other channels, should not be less than 2 meters, when the passage of time and no need to operate its headroom height of 0.7 meters. 4, the boiler room is provided for two or more boilers, the boiler the distance between adjacent not less than 1 to 1.5 times the cylinder diameter of the boiler. 5, the boiler room is generally preferred fireman operation chamber provided, on the total rated greater than or equal evaporation 4t / h blast furnace steam boilers (heating or hot water boiler is equal to or greater than 2.8MW) must be provided stoker operating room. Electric boiler tank may be provided in front of the boiler, and to ensure the art to fireman facing boiler water gauge, pressure gauge and other instruments during operation. 6, to the total rated evaporation 2t / h fuel gas boiler room to be provided or water spray foam fire extinguisher system, should outdoor outdoor fire hydrant, other fire-fighting equipment should also have the boiler room. 7, the fuel in the boiler room daily oil tank, the oil pump is generally not located in the boiler room, between daily oil tank, the oil pump between the application of the fire resistance of greater than 2.00h wall, the fire resistance of greater than 1.50h floor spaced from the other parts. Daily fuel tank between the boiler room and the door between the oil pump should be able to self-closing fire doors Class A, and let the oil block measures. Household upper tank return pipe to be provided, should be greater than the oil return pipe back to the oil pump. 8, an oil tank and all piping must have a reliable electrostatic grounding, the grounding resistance should not exceed 30 ohms. 9, gas boiler room boiler design should also comply with the relevant safety requirements of gas boiler room.

Battle blue horn sounded, emissions of sulfur, nitrogen and oxygen compounds gradually strict national requirements. To improve the quality of the environment, but also the people a blue sky, in all industries around the environmentally friendly product revolution, Hainan Sinochem Pharmaceutical companies are no exception. By the company investigation and comparison of boiler products, in March 2017 signed a six-ton ​​steam-cleaning integrated condensing gas boiler and steam fast boiler. Tested and post feedback, the boiler equipment installation qualification, operating normally, and successfully passed the inspection by local quality inspection departments of the boiler.