gas water boiler for architectural material industry

Furnace pulverized coal fired boiler is smaller than you: Today saw a piece of content, said: with the same capacity, oil-fired boiler furnace is smaller than pulverized coal. why? The following reasons: the size of the furnace volume, in the boiler capacity is determined, depending on the size of the volume of heat load. Volumetric heat load size is mainly determined by the type of fuel. After the fuel into the furnace, it will take some time to burn. Typically all the required fuel burn before leaving the furnace, the pulverized coal burnout is obviously longer than oil, i.e. coal flame longer than oil. To ensure long-term safe operation of the boiler, not only to prevent the boiler slag, and flue gas at the furnace exit is low to make the temperature at the start of the deformation ratio of ash flue gas temperature 50 ~ 100 ℃, at the outlet of the furnace and to prevent subsequent convection slagging heating surface. In many coal ash content, coal-fired furnace to control the furnace exit gas temperature typically of 1050 ~ 1100 ℃. The fuel oil furnace because very little ash, furnace slag is not dangerous, do not consider the problem of slagging furnace slag discharge outlet pipe, so the furnace exit gas temperature can be higher. For the above two reasons, the volume of the thermal load is higher than Pulverized fuel boiler. Pulverized volumetric heat load is about 145 ~ 185kw / m3, and the volumetric fuel burner heat load of up to 255 ~ 350kw / m3, so the same volume of the furnace fuel burner furnace capacity is relatively small pulverized coal fired. Rinse water gauge oil-fired boiler

State all the more attention to environmental protection, to provide more excellent atmosphere, we respond positively to the country's environmental protection, promote the boiler from coal to gas project. Among the many boiler suppliers, we chose the fast boiler. First, the party quickly done very well in terms of cleaning the boiler, the second is fast side also very comprehensive after-sales involved. The optional gas boiler was used after running fully meet the needs of our pharmaceutical production, both energy-saving and environmental protection, but also a very high thermal efficiency, saved us a lot of fuel costs. --customer feedback

The electric boiler, also known as the electric water boiler for architectural material industry, the electric drinking water boiler, the electric tea boiler, and the electric tea stove, is divided into two types: continuous electric water boiler and split tank electric water boiler, which are designed to meet the needs of more people drinking boiled water. A kind of drinking water equipment using electric energy to produce hot water is developed, which is mainly suitable for the use of schools, hospitals, factories, supermarkets, shopping malls and other population-intensive units. The main component of the electric water heater is the electric heating tube which plays the role of heating. It is better to choose the electric heating tube with insulating material, which has high safety factor and long service life. Under normal conditions, it can work for 6-7 years. The electric hot water boiler is also called the electric heating boiler, the electric bath boiler, etc. The electric hot water boiler is the production hot water that adopts the latest electric heating technology and the control system design, satisfies the heating or the supply life, Fully automatic environmental protection boiler of hot water for bath. This kind of boiler is suitable for hot water and heating in hotels, villas, factory buildings, office buildings, government agencies, colleges and universities, hospitals, troops and other places with high appearance requirements. The electric boiler is divided into two types: direct heating type electric boiler and regenerative type electric boiler. As the name implies, the direct heat type electric boiler is no longer explained here, and the regenerative type electric boiler is based on The power sector encourages electricity heating during trough periods and enjoys preferential electricity prices, introducing a new, efficient and energy-efficient electric heating product. Regenerative type electric boiler is composed of heat storage water tank and auxiliary equipment, which makes use of hot water heating in heat storage tank to achieve the goal of using all or part of the low valley power from the purpose of making use of the hot water in the heat storage tank. Electric steam boiler is also called electric steam boiler. Electric steam boiler is a steam boiler which uses power source to heat and produce rated pressure. Steam boilers can be used in textile, printing and dyeing, paper making, food, rubber, plastics, chemical, pharmaceutical, iron and steel, metallurgy and other industrial products processing process Steam is required and can be used for heating, bathing, air conditioning and hot water in enterprises, institutions, hotels, schools, catering, and service industries.

01. The reason why the ignition rod of gas-fired boiler burner does not ignite: 1. There is carbon slag in the gap of the ignition rod, there is oil pollution. 2, the ignition rod is cracked. Damp. Leakage. 3. The distance between the ignition rod is not right, too long or short. 4, the distance between the ignition rod is not right, it is too long or short. 4. Ignition rod insulation outer skin is damaged, short circuit to the ground. 5, ignition cable and transformer failure: cable broken, connector damage caused by short circuit fire; The transformer is out of line or out of order. Gas-fired boiler burners failure, ignition rod non-ignition treatment measures are as follows: clear, replace, adjust distance, change wire, change transformer. Second, the reason why the ignition rod of the gas-fired boiler has sparks but does not ignite: 1. The ventilation clearance of the cyclone disc is blocked by carbon deposition and the ventilation is poor. 2, the oil nozzles are unclean, clogged or worn. 3, the setting angle of the air door is too small. 4, the distance between the tip of the ignition rod and the leading edge of the oil nozzle is inappropriate (too prominent or indented) 5, The solenoid valve of the first oil gun is blocked by debris (small fire gun) .6, the oil quality is too viscous to flow or the filtration system is clogged or the oil valve is not opened, which causes the oil pump to absorb insufficient oil, the oil pressure is low. 7, the filter of the pump itself is blocked. 8, Oil contains more water (boiling noise in heater). The measures to deal with spark but not ignition of ignition rod of gas-fired boiler are as follows: clearing; cleaning first, if no replacement; adjusting test; adjusting distance (3~4mm is good); remove cleaning (cleaning parts with diesel); check pipes and oil filters, insulation equipment; remove oil pump outer screws, carefully remove the outer cover and remove the inside net, wash with diesel; replace it with new oil. Third, when a small fire of a gas-fired boiler is turned into a fire, the reasons for its extinction or flickering instability are as follows: (1) the air volume of the air outlet of the fire is set too large. 2, The oil valve fretting switch (the outermost group) of the fire is improperly set (set higher than the air flow of the fire valve) .3, the viscosity of the oil is too high and not easy to atomize (heavy oil). 4, the distance between the cyclone disc and the nozzle is inappropriate. 5, To wear or soiled the nozzles of a fire. 6.The heating temperature of the reserve oil tank is too high, causing the steam to cause the oil pump to send oil unsmoothly. 7, the oil in the burning oil and gas hot water boiler contains water. Treatment measures to extinguish or flicker unstable when small fire of gas-fired boiler turns to fire normally: reduce test step by step; raise heating temperature; adjust distance (between 0~10mm); clean or replace; set about 50 ℃ or so; change oil or drain water. 4. Causes of noise increase in gas boiler burners: 1, shut-off valve or insufficient oil intake in the oil path, blocking of oil filter. 2, low inlet temperature, too high viscosity or too high intake temperature of pump. 3, oil pump failure. 4, oil filter blocking. 4, oil inlet temperature is low, viscosity is too high or pump inlet temperature is too high. 3. Fan motor bearing Damage. 5, fan impeller is too dirty. Treatment method for increasing noise of Burner in Gas-fired Boiler: (1) check whether the valve in the pipeline is open or not, and the oil filter is working normally. Cleaning pump itself filter screen. 2 oil heating or lowering oil temperature. 3 replacement pump. 4 replacement motor or bearing. 5 cleaning fan impeller.

01: the greatest benefit of economic use of gas-fired steam boilers is that they can save large amounts of material costs for enterprise users, without the need to spend heavy money on large amounts of coal-carbon fuel. Only clean natural gas can be used to burn and release the steam used. Natural gas can also increase the thermal effect and reduce the cost of material input for users. Safety: natural gas is well known as one of the safest non-toxic and pollution-free clean fuels, unlike liquefied gas or gas leaks that precipitate on the ground and even cause accidents. Gas-fired steam boiler is the safest way to choose natural gas in the process of transporting gas, and it is easy to leak. Being found to be used is therefore the safest way to use it. 3: the convenient gas-fired steam boiler is also the most convenient one in use, so it will be favored by the customers of various enterprises. Natural gas pipelines are as convenient as tap water for domestic use, and sustainable use will not be bothering you. It eliminates the cumbersome work such as transporting or stacking coal and cleaning coal residue. 4: clean gas-fired steam boilers are highly rated in the market because they are clean and clean in use and free of black pot bottom and exhaust gas pollution. So it's cleaner than any other boiler in use. One way, whether directed at operational work or surrounding residents or the business itself, can be cleaner without compromising physical and mental health.

1. 20 tph wns package oil and gas boiler

WNS series gas boiler is a kind of safe and high efficiency(98%) heating equipment with full automatic control system. This series oil gas fired boiler is horizontal type package fire tube boiler with three pass structure, it has compact structure, small volume, strong load adaptability and low water quality requirement. wns package boilers adopt wet back structure, it can adapt to the high temperature, has a good sealing, increase the radiation heat transfer area and improve the heat transfer efficiency.