Commercial Seller 6t Natural Gas steam boiler Kuwait

Greater than 65t / h industrial boiler of what air pollutant emission standards should be executed? A: The State Environmental Protection Administration, Central Division-standard [1993] No. 012 document pointed out that the emergence of a small number of parameters currently higher than GB1921-80 "industrial commercial seller 6t steam boiler kuwait parameters Series" and GB3166-82 "hot water boiler parameters Series" layer burning, stoker boiler, regardless of its use Zanan GB1327-91 execution. Therefore> 65t / h or more (except coal, circulating fluidized bed, and fuel, gas fired boilers) industrial boilers should be performed "boiler air pollutant emission standards."

Tail gas boiler heating surface, promote energy conservation, commercial seller 6t steam boiler kuwait, make full use of surplus gas, iron and steel ring can be part of the No. 2 boiler recently implemented gas utilization upgrading the premise of low temperature corrosion does not occur. The transformation of the original two No. 2 Power Station Boiler 220 t / h circulating fluidized bed boiler, the transformation of 200 tons / hour gas-fired boiler. To reduce the cost, Shaoguan Iron & Steel ring portion can be modified in the original boiler equipment, removal coal system, discharging systems, dust removal systems, fuel systems; Lee used equipment including the original boiler water wall, drum, steel frame, platform escalators, tail shaft convection heating surface, steam systems, water systems and some electrical, instrumentation and other facilities, while adding the blast furnace, a coke oven gas in each system, the new blast furnace, coke oven gas mixing burner 4, the combustion of blast furnace gas device 4, a low-low pressure economizer, the boiler flue gas boiler guaranteed emissions compliance and four 10 kV high-pressure fan, part of the electrical and gas drainage, tail heating surface is not provided at a low temperature corrosion occurs meter facilities. No. 2 boiler after the upgrade, to ensure the boiler flue gas emissions standards and low temperature corrosion tail heating surface does not occur under the premise, as far as possible be able to mix more burning oven gas, surplus gas consumption, save energy and reduce environmental pollution.

The commercial seller 6t steam boiler kuwait can be divided into three kinds according to the fuel (electricity, oil, gas), such as electric steam boiler, oil steam boiler, gas steam boiler, etc. According to the structure can be divided into vertical steam boilers, horizontal steam boilers, small steam boilers are single, double-return vertical structure, large-scale steam boilers are mostly three-way horizontal structure. If according to the classification criteria above, there are a lot of steam boilers, take an ordinary fast-packed 4-ton steam boiler. Water is heated into steam in the drum and heat is emitted by fire in the furnace, which is the principle of the steam boiler. Steam The combustion part of a steam boiler consists of a chain grate and a drive device, together with a combustion chamber composed of a boiler rack on the grate frame. Surrounded by refractories. Coal from coal hopper, there are coal gate to control the thickness of coal seam while sealing the front of the air. The lower part of the combustion chamber is the place where the blast enters. This steam boiler has great resistance and needs forced blast. The cinder of a steam boiler, discharged from the back of the grate through Eagle's mouth iron and sent out of the furnace by a slag extractor. Steam boiler flue gas from the back of the boiler, by the steam boiler drum one-way smoke pipe forward, from the two-way smoke pipe back to the rear, then into the dust collector to separate ash, and then through the induced fan from the chimney exhaust Out. The above is the working principle of steam boiler, of course, the operation of steam boiler without other equipment, such as the induced fan not only undertake the task of exhaust flue gas, but also the steam boiler negative pressure operation necessary. There are also pressure vessels, thermometers, safety valves, pressure gauges, pumps, steam pumps, etc. All are essential for steam boiler work. Pump leak problem. The actual output flow rate of gear pump is smaller than that of theoretical flow due to the leakage of gear pump in the process of operation. The main leakage channel of gear pump is through the gap between the two sides of gear and the cover plate on both sides of the gear, which is 75% / 85% of the total leakage of the pump. Radial clearance leakage between gear top circle and inner hole of pump; clearance leakage through gear meshing. Because of the leakage of gear pump, the output pressure does not go, which affects the range of use of gear pump. In order to solve the problem of low output pressure of gear pump, the way of adding floating sleeve or elastic baffle on both sides of gear pump is adopted to reduce the leakage of gear pump and improve the output pressure of gear pump. Radial force imbalance problem. In the working process of the gear pump, the pressure on the outer circle of the gear is not equal, which results in the radial unbalance force at the shaft and bearing of the gear. This radial imbalance will accelerate the wear and tear of the bearing, reducing the bearing The service life also may cause the gear shaft to deform, causes the tooth top and the pump body inner hole friction, damages the pump body, causes the pump not to work normally. The common solution is as follows: (4) opening pressure balance slot on pump, leading high pressure oil to low pressure area, but it will increase pump leakage and affect pump volume efficiency; (2) reducing the size of the pressure chamber, reducing the pressure area acting on the gear teeth, and thus reducing the radial unbalanced force.

To conscientiously implement the CPC Central Committee and State Council "on the overall strengthening of environmental protection and resolutely fight pollution prevention advice tough fight" and "the State Council on the issuance of three-year winning the Battle of the blue sky plan of action," the spirit, boiler emissions control, prevention and treatment air pollution, the State environmental Protection Department to develop "boiler air pollutant emission standards." In order to further the implementation of air pollution control operations, all regions at the same time meet the national standard, but also have introduced a more stringent local standards.

From the implementation of the Beijing gas nitrogen oxide emission standards for boilers began 30mg, emissions from gas-fired boiler has been of great concern, expand around the "coal to gas" action, so that gas such devices become the most countries to promote clean energy boiler.

The transformation of the current common low nitrogen boiler, there are three main measures: (1) replacement of boilers, (2) replace the burner (3) in the boiler flue gas treatment.

Controlling the nitrogen oxide generated from the source, the most advanced technology on the market today is the use of flue gas recirculation techniques and FGR premix combustion gas boiler technology, both having different focus, low nitrogen emissions boiler.

Replace the boiler burner, renovation and debugging, and the impact on the safety performance of the resulting boiler, burner unit by the responsible manufacturer or his authorized. Beijing Bureau of Quality and Technical Supervision, Beijing Municipal Environmental Protection Bureau issued the "Notice on the transformation of the low - NOx combustion safety risk warning" states: the transformation of low-nitrogen combustion boiler diverse, complex technology, to protect the smooth implementation of the work of reform, effective prevent security risks, prevent accidents, analysis and appraisal by experts, it is not recommended comprehensive safety, environmental factors, the following recommendations:

Nitrogen oxides have been generated by some means and then reduced to nitrogen, the main fuel reburning, selective catalytic reduction, selective non-catalytic reduction. But in the actual monitoring, the nitrogen oxide emissions controllability is poor.

The transformation of low nitrogen gas boiler is a need for long-term adherence and actively manage the work, under the premise to meet the national standards, do specifically address the specific circumstances, not blindly, careless handling, to adopt plans, goals, ideas implementation, to achieve a comprehensive upgrade gas boiler.