hot water boiler Cheap 20 ton Industrial Malaysia

In July 2013, the 260t/h high pressure CFB coal fired boiler in Indonesia is in successful operation. Now the boiler maintain the rated capacity at 260t/h in a long term, and the power generation is 90MW. The technical parameters, such as steam temperature, pressure, efficiency and exhaust temperature reach the design requirements.

Lanzhou City, Gansu Province, the transformation of coal-fired boiler control policy in accordance with the latest introduction of the "not big on the small" principle to give "Yijiangdaibu" financial support to owners of units, specific subsidies are as follows:

1, for a single 1 ton / hour or more than 0.7 megawatts of clean energy and coal-fired boilers by 100,000 yuan to subsidize steam tons of standard /.

2, coal-fired heating boilers mentioned standard governance and meet the national air pollutant emission limits in particular boiler, according to subsidize 50,000 yuan / ton steam standards, subsidies does not exceed 30% of the total investment quota.

3, for a single 1 ton / hour or 0.7 megawatts of utility units (including schools, health centers, hospitals, neighborhood or township government offices and other public units) clean energy transformation of coal-fired heating boilers in accordance with the actual heating area subsidies, allowances of 100 yuan / square meter.

When the gas boiler room Gas boiler room gas leak state identification serious leak, the following phenomenon: the working gas pressure changes. In the vicinity of the leak can hear the sound of a strong air flow. Hand-held alarm will be issued abnormal sound. Leakage larger (higher concentration) fixed alarm will sound alarm, automatic opening of the exhaust fan. Boiler or gas pipeline explosion disasters occur in severe cases, fire.

New coal fire late, often appear off the fire bed fire, fire away from coal gate about 0.6 ~ 1.Om, burning furnace is not strong, high ash carbon content. For existing furnace arch structural problems, from improving fuel fire conditions, improve furnace temperature begin to transform the boiler. After the furnace arch after the transformation, the people stove fuel from coal gate 0 · 3mRP fire, the fire bed combustion intense flame full of good, strong rotation. Since lowering the front arch, the arch extended, reduced to about 1 2 throat formed between the arch of the original pitch. Where the enhanced mixing flow disturbances, reorganized stream, enhanced combustion furnace, to effectively improve the temperature of the entire front region and the arch of the furnace, to reach 1400 degrees, the condition of the fuel to improve ignition.