crude oil steam boiler top quality

Oil-fired boiler work and preparation before purchase if necessary fuel boiler induced draft fan, this is a particular kind of boiler, and all of us concerned, but also need to have a comprehensive knowledge and understanding, so as to know how to correct and rational use of oil-fired boilers this a boiler at the same time to achieve the purpose, can also increase their expertise in this area. Whether to do some preparatory work before 1 oil-fired boilers to buy? Oil-fired boiler product before making the purchase, it is the need to do some preparation work. Moreover, this work has two purposes, first, the importance of this work reflects the product purchase, and second, to avoid the wrong choice appears. In the specific content of the work, first have a clear understanding of the environment and the requirements of the product, the second is some basic information to understand the product and production manufacturers, including product origin, specifications, size, performance and technical parameters, product quality and price and product service, in the process of considering these factors are indispensable to ensure accurate judgments and the correct choice. 2. Fuel different classification criteria boiler Are there different kinds? Oil-fired boiler, which is a specific kind of boiler, so, as with a normal boiler, at different classification criteria corresponding to different species, therefore, the answer to this question is yes. If the kind of fuel according to points, can be divided into two oil-fired boilers and boiler heavy gas oil boilers, diesel or gas oil refers to the kerosene, heavy oil is extracted by means gasoline or diesel oil as the rest of the heavy oil. In addition, the boiler according to purpose to points, can be divided into a fuel oil-fired boiler water boilers, hot water boiler fuel, heating fuel boilers, boiler and fuel oil bath and crude steam boiler top quality these. 3. The oil-fired boiler fuel consumption calculations it important? From a professional point of view, to calculate oil-fired boiler fuel consumption is very important work, and careless treatment can not be ignored, because if get the wrong result, it will affect the normal use of the boiler. In addition, we also need to know is that there is a corresponding formula, under normal circumstances the use of boilers, boiler output if different, then the boiler fuel consumption is not the same. 4. Does fuel boilers must have induced draft fan? There are requirements for the quality of its oil do? Whether fuel boilers must have induced draft fan, according to this aspect of professional presentation, the answer is not necessarily, because depends on whether the specific circumstances so require, if the amount of air supply and flue fuel ratio appropriate and clear then use the blower can be. This kind of boiler oil-fired boiler, its oil quality is not clearly defined requirements, but in the use, certainly requires better quality fuel, so as to ensure the boiler work properly.

Dry: six gas-fired boiler safety procedures (hot water + steam) stage, the purchase of gas-fired boiler more and more users, in many industries, such as oil exploration, hospital disinfection, chemical production, wine feed, and so on. But many users initial contact with a gas boiler told us how to get started quickly boiler operation is not clear. First, all personnel must be familiar with the operation of the boiler boiler performance and safety knowledge, certificates; this non-job employees Never operate. Duty personnel should strictly follow the regulations, do a good job operating records and shift recording, the security situation should shift equipment and run tests, carried out. When the shift to check the boiler is intact. Second, purchasing, installing, or before the initial operation of the boiler, the boiler and safety accessories must conduct a comprehensive inspection, inspection and determined within the validity period to start. Third, Kai furnace ready to check the gas pressure is within the normal range of values, not too high or too low; check whether normal pump Sheung Shui, if unusual you need to open the purge valve until the Sheung Shui so far. Open the door of each section Water Supply System (including Sheung Shui before and after the festival gates pumps and boilers); check the water level, the water level should be in the normal position, the water level gauge, a water color need to plug in the open position, to prevent false water level, if missing water can be manually Sheung; check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob inspection control cabinet are in their normal position; crude steam boiler top quality check valve is in the normally closed state, heat water boiler circulating pump outlet valve should be turned off; check water softening equipment is operating correctly, soft indicators of compliance with national standards. Fourth, Kai furnace run time 1, steam boilers Open the power to start the burner; check manholes, hand holes around the flange and valve leaks will be tightened, if there is still leakage after tightening occurs, you need to immediately stop maintenance furnace; l when the air pressure 0.05 ~ 0.1MPa, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; when the pressure was raised to 0.1 ~ 0.15MPa, rinsed trap gauge; pressure was raised to 0.3 MPa, the "fire load / small fire" knob to "fire" to strengthen the combustion; 2/3 when the air pressure was raised to the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; out when the drain valve when steam is completely close it; after all drain valve closed, slowly open the main valve to open, and then half a turn; "burner control" knob to "Auto"; level adjustment: adjusting the water level (according to the load manually when to start and stop the pump), low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; steam pressure adjustment: adjusting the combustion load in accordance with (manual adjustment fire / small fire) determines combustion conditions The flame color, smoke color determination condition atomisation air quantity and exhaust gas temperature observed concentration chimney, the best change in the combustion temperature to be adjusted according to the combustion. 2, start the circulation pump hot water boiler; startup burner; 15 minutes after start, "" fire load / small fire "spin-bit color button to" fire ";." Burner control "knob to" Auto "five, normal stop 1 furnace, hot water boilers' fire load / small fire "knob to" small fire "; off the burner; close the fuel supply valve; closing dampers; boiler after the temperature dropped to 50 ℃, the pump outlet valve closing cycle ; .2 circulation pump is stopped, the position of the steam boiler "fire load / small fire"; Close combustor; steam pressure drop when the sewage to 0.05-0.1MPA; closing the main steam valve; manual replenishment to the higher level; Close valve; Close supply valve combustion; closed dampers; six off the main power, an emergency shutdown, the steam boiler main steam valve closed; off the main power; 2, boiler water boiler inlet and outlet valve closed; opening the emergency valve and the emergency discharge replenishment valve; off the main power switch; notification superiors.

The global market for industrial horizontal boilers increased from nearly $8.9 billion in 2011 to nearly $9.4 billion in 2013. This market is expected to reach about $12.5 billion by 2018, equivalent to a compound annual growth rate (CAGR) of 5.9% over the five-year period from 2013 to 2018. We offer Industrial Boilers such as petroleum / Oil / Gas Steam Boilers and Steam Boilers.

Fast Boiler Co., Ltd. is a really truly think about your clients practical solutions to business problems, this recommendation after this water-tube boilers put into use, the quality inspection departments, the nitrogen oxide emissions, soot and other indicators They are in line with national standards, but also very full of fuel combustion, high thermal efficiency, saves us a lot of fuel costs. This cooperation, I am very satisfied. --customer feedback