8t Natural Gas steam boiler Commercial Agent Singapore

The main function is to ensure that the monitoring system burner safe and stable operation, the main components are: flame detectors, pressure monitors, temperature monitors and the like. Flame detector: monitoring conditions for forming the flame, and generates a signal reporting programmer. There are three main flame monitoring: photosensitive resistance, electric eye UV ultraviolet, ionizing electrode. Pressure Monitor: generally used for a gas burner, the main high-pressure gas, low voltage detection, and detecting elegant, if burner for 8t steam boiler commercial agent singapores, and steam pressure monitoring. Detector Temperature: monitoring and controlling the temperature of fuel (heavy oil).

Fast boiler particularly strong technical team, they listened carefully to our needs and give us tailored technology solutions, from boiler production, transport to the site installation and commissioning took only 35 days time, all aspects of the deal in place, the boiler quickly it is put into use. --customer feedback

Matters needing attention in loading and installation of Gas-fired Steam Boiler

Gas-fired steam boilers are a very wide range of special equipment, usually built in boiler rooms. However, in the process of loading and installation, some problems must be paid attention to, otherwise it may cause a certain degree of economic loss.

1. Pay attention to the following matters during the loading and unloading and handling of gas-fired boilers: the lifting capacity of the lifting equipment should match the weight of the lifting boiler. The lifting lug on the boiler with the lifting lugs that cannot be used for lifting can not be used for lifting. The length of the steel cord should be reasonably selected to avoid the scratching of the furnace due to the improper length of the steel cord. The boiler must be protected from any damage during handling and handling.

2. Reserves for maintenance space When installing boilers, ensure that there is sufficient maintenance space around the boiler.

3. Setting and precautions for the base and base of the gas steam boiler The boiler body must be installed on the basis of 100-150mm above the floor of the boiler room. It must be confirmed with the technical personnel of the boiler manufacturing company in advance and constructed according to the basic drawings. The anchor bolts must be reserved on the foundation. The foundation shall be capable of withstanding the maximum weight of the boiler and the amount of water it holds. When installing the base, you must first position it. After positioning, adjust to the same length of the two diagonals of the base, and then tighten all the fixing bolts. The installation of the base is carried out with reference to the reference line.

4, general precautions Be careful not to tilt and impact the boiler and accessories too much. No combustibles can be placed around the boiler. Do not use oil and water to smother the boiler. The boiler should normally be installed in a separate boiler room. The new gas-fired boiler room should not be connected to the house. The boiler room shall not be connected to Class A, Class B and Category C fire hazard rooms using flammable liquids. If connected to other production plants, the application firewall is separated.

What is the working principle and composition of gas-fired 8t steam boiler commercial agent singapore? Do you know any customer friends? The following is a technical explanation from the manufacturer of gas-fired steam boilers, which I hope will help you. A gas-fired steam boiler is a thermal energy conversion device that uses natural gas, liquefied gas, city gas and other gas fuels as fuel, burns the heat released from the furnace, heats the water in the pot, and vaporizes it into steam. The energy released from the combustion of a gas fuel in a boiler (pot) continuously heats up and the temperature rises to produce pressurized steam. The boiling point of water increases with the increase of pressure, and the seal of the boiler and the expansion of the water vapor are restricted to produce. Pressure is used to form thermal energy (the boiler's steam is strictly formed by constant pressure heating of water in the drum to re-vaporize saturated water) as an energy source. Gas-fired steam boiler is mainly composed of two main bodies, shell and furnace body, and an accessory, instrument auxiliary equipment, automatic control and protection system to ensure its safe and economical continuous operation. Gas-fired steam boiler is a boiler type boiler with water-cooled crucible. Gas-fired boiler has two return pyrotechnic tubes, arranged on the left and right sides, the front of the drum in front of the cigarette back. Between the roller and the lower box, there is a lower tube and a water-cooled manifold to form the frame of the combustion chamber. Roll There is a steam separator at the top of the tube to reduce moisture in the steam. The heating surface of the main body of the gas-fired steam boiler is the lower part of the drum, the water-cooled manifold and the pyrotechnic tube. It is very energy-efficient in gas-fired boilers. He has a high cost of fuel and liquefied gas and electric boilers. Gas-fired steam boiler is also a kind of protective boiler. When used, there will be dust and gas that damage our health. There will be no such problem with natural gas. The heat efficiency of gas steamer furnace is very high, can reach more than 90%! The point is that he has a long life. He uses very clean dyes, so he doesn't produce dust and smoke in the furnace when he burns. Grey, so his life is much longer than other boilers. In the development of boiler, he is developing towards the goal of environmental protection and energy saving.