szs oil and gas steam boiler for pharmaceutical industry

Gas boiler szs 1 emergency shutdown procedures, if necessary emergency shutdown generally, when the boiler encounters one of the following, operation should be stopped in case of emergency; (1) allow the boiler steam pressure exceeds a safe pressure, fueling is stopped strengthen water supply, measures the wind pressure continues to rise. (2) boiler severe water shortages. Water meter can not see the water level. After being called water, the water level of sight. (3) When the severe water boilers, boiler water level is higher than the highest water level is visible, but the emission level not yet seen. (4) increase in boiler water, take other measures, the water level will continue to decline. (5) water supply device is turned off, standby equipment. (6) all water level gauge or invalid. (7) All the safety valve all the failures. (8) All all-off failure drain valve. (9) causing damage to the boiler pressure element (e.g., boiler tubes, etc.), or endanger the safety of the device. (10) boiler is a serious threat to other events and safety equipment. 2, natural gas boiler operation method szs immediate emergency stop operation of the controller, the boiler is off, closing the front of the boiler gas valve to stop the gas supply. The szs oil and steam boiler for pharmaceutical industry competent completely separated, opening the exhaust air valve or safety valve steam pressure. Due to lack of water, the boiler is not allowed into the boiler, the steam is not discharged to reduce pressure. No shortage of water, cold water can drain down alternate method, the water level remains complete accident should immediately stop the water supply, water reducing combustion (fire artificially changed into a small fire), play an open valve while opening the main steam pipe and the drain valve cylinder to prevent the steam to carry large amounts of water, water. In the shutdown process, the cooling rate of the furnace should not be too fast to avoid flue compression member and the expander is damaged suddenly cooled. 3, emergency shutdown processing method szs natural gas boiler in the case of emergency shutdown, due to the nature of the accident, the following may take a different approach: (1) rapid flame treatment emergency shutdown, the burner first station, and closing the valve flame gas supply is stopped after the cut valve, to maintain the water level is normal. (2) rapidly cooling the furnace or water if there is no water leakage during an emergency stop, the cooling time can be shortened to the boiler water and sanitation and reduce the pressure. When the boiler water temperature down to 80 degrees Celsius, boiler water can be discharged. If the boiler severe water shortages, the boiler can not cool quickly in the event of an outage. Non-water to the furnace, or explode. accident. (B) natural gas boiler shutdown SZS normal shutdown (complete shutdown, shutdown maintenance) procedures which can be used when needed repair or stop steam boiler. 1. If one of these faults, the leaders agreed, the boiler can be temporarily closed repair: bilge faucets, riveted joints leak, damaged tubes, the waterwall tubes, the heating tube, the flue gas contacts the drum, the head, off pipe insulation, water supply system, combustion system, a serious fail-safe accessories, in need of repair. 2, a temporary repair (or normal shutdown) the method of operation in order to stop the burner, for closing the valve. Boiler feed water to 2cm above the normal water level, to stop water supply, reduce the pressure. 3. Turn the main steam valve, open the traps, and steam boiler operation, reliable water separator. 4, boiler feed water close electric valve and manual valve, boiler feedwater reliable cutting. When the steam pressure drops to zero, the water can be supplied and discharged alternately, so that water is gradually cooled furnace, when the temperature drops to 50 degrees Celsius (or hand potshell touch feeling hot pan head), can be completely discharging furnace boiler water water . Before water, open the air valve on the boiler or lift safety valve. At this point, you can enter the furnace for inspection and repair. Cooling the furnace must be kept slow, non-violent cooling and damage to the boiler, the boiler can be stopped from the repair into the furnace, the cooling time is generally less than 24 hours. Close the furnace over 24 hours, shut off the gas supply valve at the regulator, and open the gas conduit pipe is responsible, in the exhaust gas pipeline.

Vertical projection which features good szs oil and steam boiler for pharmaceutical industry boiler having a vertical steam energy conversion device, the input of thermal energy by chemical, electrical, and high temperature flue gas to the furnace, thereby converted into electrical energy, and to provide the desired life for people heat, on the safety and convenience of all with excellent product qualities, then what good salient features vertical steam boiler has it? 1, reliable safety performance vertical steam boiler in terms of product safety has a lot of protection, by ground fault protection, overvoltage protection and power protection and other measures to make operation of the boiler can always be in a safe state, when the pressure is too low or there is leakage, the boiler will cut off its own power button, so to ensure the life and personal safety of the boiler. 2, the portable vertical steam boiler operation which is preferably used, which have to see ease of operation and convenient operation of the boiler does not require user intervention excessive production process, just to the introduction of the electric power source control box start button to enter the automatic operation state, and when the job if the amount of water in the furnace suddenly reduced, the vertical steam boiler control system is also used to automatically replenish the water in the water tank to fill the pump through the apparatus in order to achieve high efficiency of production operations process. 3, small size and yield stability compared with the conventional boiler products, the type and volume of the vertical steam boilers are an advantage, not only a wide range, and the volume of the boiler is very small, but it has a large steam room to make product productivity and quality are the most significant upgrade in order to obtain a more stable production company that won the biggest profits. The above is a brief introduction which has a prominent characteristic of a good vertical steam boiler, not difficult to find, the boiler reliability in terms of safety and convenience of operation have notable features, but also in the volume and yield stability also has a prominent feature , production efficiency and product quality to make the most significant upgrade, but also to ensure personal safety as well as the effect of the use of the boiler.

Water tube boiler for cocoa factory

A 15-ton oil and gas water tube boiler produced by ZG boiler provides steam for cocoa processing. The plant is located in Côte d'Ivoire and requires a steam boiler for production due to the expansion of production.

Exhaust gas has been plagued by sewage paper industry, paper industry pollution problems of the country very seriously. Fujian Heng paper packaging company has been committed to the use of clean-type boiler paper processing. October 22, 2016, David Carse, the paper with my company, signed a 6 tons of steam an integral condensing szs oil and steam boiler for pharmaceutical industry for the production of corrugated cardboard and other paper products. I provided the boiler greatly solve the problem of sewage wastewater Heng paper. After the boiler operation, both to meet local environmental requirements, but also reduce operating costs for the constant boiler paper products.