horizontal oil fired steam boiler 1000kg per hour

Choose suitable gas fired boiler for biscuits company

Whether you choose a Firetube boiler or Watertube boiler, large or small capacity, gas fired boiler or oil fired boiler, you’ll still get the unprecedented ZG boiler quality you demand. Now gas fired steam boiler is cost low, environmental for biscuits company, steam sterilizers generally produce sterile product reliably, and steam quality can be controlled in biscuits steam sterilization.

The main factors affecting small type gas horizontal fired steam boiler 1000kg per hour steam boiler thermal stability of gas ignition is not difficult to establish a stable small fire signal, the root cause is a small fire detectors can not detect normal to the fire. Gas-fired steam boiler burner underlying mode, two-pass configuration, the fuel combustion, the boiler operation is stable and take up less space, while the spoiler is inserted smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, reducing user fees biomass boilers categories: biomass boilers horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. Small fire detectors use the ionization fire detection, and requires effective contact area of ​​the flame, the flame stability and proper size, the gas pressure must be controlled within a very strict range. If the ignition gas pressure is too high, too long a small fire flame is moved beyond the detection range of the small fire detection probe, the system will not be mistaken for a small fire; if the gas pressure is too small, the gas will be firing too small and the boiler the blast very, very easy to blow out the flame, the ignition is not possible. Also, fire gases found a small pressure regulator valve regulating performance is not good, fine adjustment can not be achieved. Stability is also related to a small fire and the ratio of the size of the boiler furnace pressure boiler feed valve. The damper is too large or too small can affect the stability of the flame is ignited and the flame, furnace pressure will lead to extinguish the flame. In order to ensure the accuracy of fire detection, fire detection, we can adjust the small depth of insertion of the probe, the position of the fire detection probe in the correct position, in order to more effectively detect small fires flame.

China Dunhuang International Hotel relevant responsible person said, party fast or aftermarket both in pre-sales, remained consistent patient service, we have solved many difficult problems, with fast boiler, we are assured. --customer feedback

Increase productivity boiler system must first be optimized for verification, including the entire steam system for a complete analysis, and focus on some of the energy waste places. Via check can often find opportunities to save energy, increase productivity, and environmental protection have a positive contribution of. Check includes a steam generation, distribution, use and condensate recovery. The main steam waste requiring special attention place: exhaust gas boiler: boiler efficiency emissions system the most important indicators, the loss of energy is the most important place. Combustion air: general air enters the combustion furnace of the genus room temperature, require a lot of heating energy, i.e., the most commonly used power saving mode using a high temperature exhaust gas to preheat the combustion air of boiler, boiler efficiency can be significantly improved. The fuel / air ratio: Proper oil / gas mixture can only complete combustion, if the lack of air, combustion is incomplete, not only smoky pollution, environmental protests caused nearby residents, and easy carbonized grease gun and boiler heating tubes affect performance. If excess air is formed wasted energy, reducing boiler efficiency. Via the oxygen content of the tail gas can appropriately adjust the oil / gas ratio. Oil-fired boiler exhaust gas which content 3%, i.e., the excess air of about 15%, as the standard combustion control.