Industrial Seller 20 ton oil hot water boiler

Gas-fired steam boiler equipment maintenance equipment maintenance points 1: 1, or twice a day to clean up slag. 2, washed once or twice a heater dust (ash door with the appliance design) weekly. 3, once or twice a month, or butter oil feeding helical gears and bearings induced draft fan. 4, a monthly injection of butter or oil to the fan motor bearings once or twice. 5, a boiler must be 2-4 times the annual emissions (emissions must promptly after filling water). 6, poor water quality, in use. 2. Before, must soften water. Gas industrial seller 20 ton hot water boiler with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. Daily inspection equipment: 1, the fan regularly checks whether there is a feed screw loosening device, whether there is abnormal noise. 2, regular inspection trip tank float valve is normal replenishment, water pressure is normal. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. 3, if equipped with a pump, replace circulation pump on a regular basis, and check whether the pump is working properly. Function gas boiler the ignition system that ignites the mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 4, regular inspection equipment grounding cable is connected correctly. 5, to ensure the normal supply of fuel in the hopper, so as to avoid non-fuel flameout downtime. 6, it should be observed regularly combustion of the fuel in the combustion chamber. Incomplete combustion of fuel, smoke or large block to form sulfur, the sulfur should be promptly removed block and the governor to adjust the feed flow rate ratio of the fan, to achieve the desired combustion.

Henan gas boiler control system configuration Henan microcomputer controller for a gas boiler, a large screen Chinese LCD screen with bright backlight, day or night, Henan gas boiler operating state is clearly visible. Display complete: circulating pump, the operation of the burner, the boiler water temperature, water level, the current time, alarm records, Henan readily available gas boiler operating state; easy setup: the boiler power, the operator can key 6 for operating parameters at the time by going to the standby state (set) into the operating state (power on), the state out of operation (stop), the random standby state is set; functional: arbitrarily set the current time, alarm temperature, the upper limit temperature temperature, water temperature lower limit temperature, the temperature of the circulation pump is turned on, the circulation pump shutdown temperature, the boiler switch time (divided into four time periods) and other operating parameters. The operator usually just press "Start" key to boot, press the "stop" button down, is very simple. First, the characteristics 1, arranged brand combustor inlet, a high degree of automation, automatic purge controller according to the instruction, the electronic auto-ignition, spontaneous combustion, air oil (gas) automatic ratio adjustment, security and stability performance, good combustion. And there are flameout protection device, ensure safe operation. 2, the computer controller of formula bath gas boiler, all the functions are stored on a magic smart chip, a key to boot Henan gas boiler, automatic timing, temperature operation, the user can set the start, shutdown time setting is completed after, no special duty to save time, and effort. 3, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, the temperature of the flue gas discharged from a low smoke chamber, reducing heat loss and save fuel. Second, the operation 1, a large font display temperature, easy to grasp the operation status of the gas boiler and system Henan, the water temperature can be freely set from 10 ℃ to 90 ℃, Henan gas boiler automatic system to provide users with live or heating, bath with hot water . 2, the control system controls the circulation pump start and stop in accordance with the temperature of boiler water, boiler water circulating pump starts when the water reaches an upper limit temperature, lower than the hot water circulation pump stops when the water temperature lower limit. 3, three horizontal gas bath boiler return all wet back structure, using a large furnace, rough smoke tube design, increased furnace radiation heat absorption, the effective energy saving. Using threaded pipe and waveform furnace, greatly enhanced heat transfer effect, greatly saving fuel consumption. 4, while the machine is equipped with thermal protection (ultrahigh temperature furnace, the burner is automatically stopped and an alarm buzzer, the second over protection (Henan gas boiler housing temperature exceeds 105 deg.] C, the secondary circuit is automatically cut off), anti-dry burn water protection (when the furnace is less than the water level is very low, the gas boiler is stopped and an alarm beep), a boiler leakage protection (the control system detects electrical leakage, short circuit, automatically cut off the power) .5, Henan gas boiler press pressure design, the boiler is in the non-pressure state, there is no safety hazard. centrifugal using advanced multilayer insulation wool, a steel sheet for packaging famous white color, heat loss, anti-rust appearance.

Here's how to conserve water pump.

1, gas boiler feedwater pump failure prevention routine maintenance must be for the purpose of curing system and establish a scientific system to guide routine maintenance work to the pump.

2, the establishment of feed pump failure and replacement parts records, detailed grasp the parts damaged time so late in the component to be replaced before the life, avoid parts (such as: bearings, etc.) that is not timely after damage caused by damage to the unit .

3 occur, to strengthen the maintenance and regular checks amount of lubricating oil pump lubrication system, lubricating components in a timely manner, to avoid "dry grinding" and other conditions.

4, prior to the addition of the lubricating oil to be attention to check the quality and cleanliness of the oil addition port, to avoid the process of adding impurities into the bearing damage. Also note that in the conservation of the inspection and maintenance of the system piping to the pump, in a timely manner at plugging leaks, rust-proof coating the outside of the pipeline should always be checked for spray coating peeling off promptly at, in order to ensure that the tube corrosion path. Maintenance also need to pay attention to the inspection and maintenance of pump water treatment system.

Fang faster work on clean fuel boilers more than twenty years, whether it is research and development or manufacturing fields have achieved remarkable results. The launch of the "Euromonitor 5" series boilers, the company's new low-nitrogen boiler, using advanced FGR combustion technology, nitrogen oxide emissions below 30mg / m3, our first-tier cities can be used normally. Remote monitoring system is to attract the attention of the participants. Jumping curve data, real-time display operating status boiler; detailed data analysis and fault early warning program, Fang fast "black technology", making the boiler to get rid of "silly Big Ben rough" image and become intelligent high-tech incarnation.