coal boiler Factory Direct Supply Energy Saving

The United States is our national enterprise, one of the world's top 500, with very bright glory on the world stage. US air-conditioning as a subsidiary branch, with a very large market competitiveness. 2016, Hubei US air-conditioning due to market demand to expand production lines, need to purchase steam coal boiler factory direct supply energy saving to provide energy support for the new production line. After the boiler industry for a number of enterprises contrast, is determined to cooperate with the fast boiler, buy a whole 10 tons of steam condensing gas steam boiler (WNS10-1.25-Y.Q).

First, to improve the fuel will be coal into gas in principle, more in line with the relevant environmental standards, coal as fuel for the coal boiler factory direct supply energy saving has been subject to the authorities to stop, that there is often a company will be coal-fired boilers on the boiler rehabilitation programs into gas boiler embodiment, may use natural gas or alcohol as a fuel after passing through this transformation, the raw coal to reduce all kinds of pollution caused by the fuel, thus using not only environmentally friendly but also improvement in the fuel cost. Second, improve coal-fired furnace boiler furnace to transform into a blast furnace gas fired boiler is the use of auxiliary heating furnace, and then to improve the use of gas for heating, if not exactly when or poor fuel atomization in the combustion furnace gas gathering or tail, it is very prone to catch fire or explode, then the need for means to improve the furnace blast doors, while adding automation and control ignition and flame failure protection devices to ensure safe operation of the furnace process. Third, improve the pre-attached devices did not improve during the coal-fired furnace operation requires a lot of ancillary equipment to carry out normal operations, ancillary equipment commonly used in general including the coal, Cleaner, dust collector and grate and so on, after adoption of these boiler ancillary equipment gas furnaces do not need to use so that you can save and invest more of boiler equipment. Fourth, improve environmental protection degree We all know that coal-fired furnace has been impermissible environmental policy, coal is a serious source of pollution not only pollutes the environment but also cause a variety of effects on the body, after making use of the boiler gas furnace, greatly reducing soot and various soot emissions can effectively improve air quality, more environmentally better protect the cleanliness of the air, but also more in line with the standards of environment protection and energy policy.

How to choose a reasonable price brand of industrial coal boiler factory direct supply energy savings How to choose a reasonable price brand of industrial boilers, fuel gas-fired boiler, good insulation properties, clean and green, the boiler thermal efficiency advantages, is currently popular on the market a boiler in addition to gas-fired boiler has its own characteristics, the full implementation of the national coal policy to further promote gas-fired boiler coal-fired boiler to become the user's preferred furnace, gas boiler market demand continues to grow. There are many brands on the market boilers, boiler quality is not uniform. For users, how to choose the right brand of industrial boilers price is very important. How to choose the affordable brand of industrial boilers, we all know that smoke respirable particulate matter is the culprit, but in fact, another reason - nitrogen oxides can not be ignored. Coal project promotion, gas boilers ownership will continue to increase. Coal combustion gas may reduce the pressure of the coal, to reduce the concentration of airborne particulate matter, nitrogen oxides, but also an important reason for the smoke, which generates an important condition is a high temperature. Gas boiler for heating and the heating temperature needs. Many gas SO2 emissions from large boilers on the one hand is greatly reduced, on the other hand produce large amounts of nitrogen oxides. Fast side gas boiler gas boiler can be reduced to nitrogen oxides emission concentration 30mg / m or less. With the implementation of the new emission standards across the country over the next three to five years to use low nitrogen gas boiler to improve the cleanliness of a large number of industrial buildings and residential heating gas boiler emissions.

Operation of a gas coal boiler factory direct supply energy saving gas boiler in Henan related to maintenance, the ignition operation, fire, shutdown and some other operational measures: First, the gas boiler maintenance Henan, operating procedures should be required to carry out tests on the gas transmission main boiler protection devices, ensure that the main protection correct action. Second, the ignition process Henan gas boiler, fuel pressure, fuel temperature, steam pressure atomization, atomization steam temperature and other parameters must meet the requirements of operating procedures, good place to observe oil gun fire, fire detection return to normal, prohibit short-energize inspection signal forcibly put into the oil gun running. Single oil gun when the flow is greater than 0.65kg / s, exit the gun should be run immediately. Third, observe boiler ignition temperature rise rate of fire smoke significantly Pianman furnace flue gas temperature of the main steam temperature, steam pressure rises when the main, the case of smoke or boiler ignition temperature did not rise immediately to check the opinions of the oil gun, if No fire was found after the fuel into the furnace, emergency shutdown, re-ventilate the furnace purge Do not allow to run into the boiler ventilation oil gun. Fourth, note that starting mill to check whether the subject returns normally coals, coal mill outlet temperature of greater than 70 deg.] C line is allowed to increase the amount of coal (three grinding mill operation start of the fourth stage, the coal mill outlet line than 80 ℃ temperature allowed to increase the amount of coal, to prevent excessive vibration furnace). Full stop before the gun when the present discharge amount of coal is increased 5.0kg / s or more. 6.3.5 Operating Henan gas boiler, "furnace black", "lose the protection of the main fuel" must be put into operation as required operating procedures. In case of a fault protection device itself appears to be temporarily out of operation, to be approved by the competent manager or chief engineer before implementation. "Furnace black", "main fuel unprotected" means the period out of operation, priority monitoring attendant to furnace pressure, the oxygen, the main steam temperature, the main steam pressure and other parameters, and through the furnace of fire industrial television monitor, and if found hearth fire, emergency shutdown. Sixth, Henan gas boiler normal operation, the fuel system and oil spare gun good condition, found that boiler combustion instability immediately put oil combustion. Seven, after Henan gas boiler fire, into the oil gun is strictly prohibited without the operation of the boiler ventilation. Eight, gas boiler has confirmed the fire, when the MFT is not operating, emergency shutdown, and check that the two primary air fan, 4 mill, 16 oil gun has stopped running. Back nine, Henan gas boiler trip or normal shutdown to be purged immediately ventilate the furnace, the furnace unburnt coal dust and combustible gas pumped in a timely manner. And promptly shut down the boiler supply and return oil total gate manually to prevent leakage of fuel oil gun into the furnace. Ten, Henan gas boiler shutdown purge gun ban mill and pulverized coal into the furnace exhaust.