Supplier 8t Natural Gas boiler Vietnam

Tai Chi, Jiaozuo City, Jiaozuo City Sports Center is one of important sports infrastructure, a total area of ​​11.73 hectares, held several international events. With strict management in Henan Province for air emissions of pollutants, Jiaozuo City, also launched the governance of coal-fired supplier 8t boiler vietnams, thermal power and other equipment. Jiaozuo Sports Center actively cooperate with municipal workers, took the lead from coal to gas activities, the serious pollution of the original extent of coal-fired boilers to replace gas boilers. Gas boiler cleaning binding understanding of the market, to achieve cooperation with the finalization fast boiler by providing a fast side 2.8MW integrally condensing gas hot water boiler (WNS2.8-1.0 / 95/70-YQ), it is used to Sports Center provides heating and hot water.

If a single burner extinguishes, there may also be a deviation in the center of the furnace flame, and the air pressure of the extinguished burner may change. If the fuel supply is interrupted, the oil pressure or pressure indication of the extinguished burner may decrease to zero, while the fuel and gas pressure of other operation burners may rise. After the occurrence of the above situation, the supplier 8t boiler vietnam must be handled in a timely manner to ensure the safety of use.

Gas oil furnace gas consumption and related questions can automate operations: conducting oil furnace oil furnace gas this kind, it is also the product website and keywords, it is necessary to know and understand the subject, otherwise, can not be familiar with the site and its manufacturer. Therefore, in order to achieve this goal, the following will be introduced to the product description, so that we have to learn content, and thus, can be development and progress in their learning path. 12 000 kcal conducting oil furnace gas, if gas is natural gas which, then, the upper limit of the supplier 8t boiler vietnam air consumption of natural gas, how much is? 200,000 kcal conducting oil furnace gas, if it is natural gas, then, the air consumption of the boiler gas limits are as follows: 200,000 divided by the gas heating value and thermal efficiency of the boiler, so as to obtain a particular value . If the boiler thermal efficiency is 94.8%, then, is the specific results of 24.8 cubic meters / h.

Method of reducing the exhaust gas temperature of the supplier 8t boiler vietnam which: standard boiler exhaust gas temperature: between the boiler flue gas temperature of 200-230 deg.] C in accordance with conventional design national standard thermodynamic calculation boiler design requirements. Conventional exhaust gas temperature selected reasons, coal fired boiler combustion process will produce a certain amount of SO2, and SO2 below 170 ℃ will bind and generating flue gas H2O H2SO4 sulfuric acid, H2SO4 sulfuric acid and will form boiler heating surface of tail corrosion, thereby reducing the life of the boiler, conventional coal-fired boiler exhaust gas temperature is higher than 200 ℃. Temperature is high energy loss and more, is not conducive to energy saving. Cooling measures taken to ①, the economizer application: increasing the boiler economizer (economizer) of heat transfer area, larger than the conventional take about 1-2 times the flow cross sectional area economizer structure, effectively reduce smoke flow rate, to strengthen the heat transfer efficiency, reduce exhaust gas temperature; ②, air preheater applications: pipes connected to the air preheater economizer disposed, the apparatus can effectively increase the temperature of the combustion air, improving the ignition of the fuel condition. Very beneficial to the boiler combustion conditions. ③, adjust bidirectionality combustion system, a boiler originally designed for fuel specifications have some flexibility, different media in effect outside the combustion process are different, adjusting the embodiment, with the economizer and the air preheater using, the temperature of the boiler exhaust emission control at a suitable temperature, that make full use of heat energy, but also to ensure the integrity of the structure and function of the relative equipment, environmental protection, energy saving, security and development is the social responsibility of all of us for a rational design of industrial structure boiler, thermal efficiency is relatively high, its emissions would be relatively low temperatures, so we must be careful when choosing a boiler boiler property report form.