brand wns type gas steam boiler industrial

Works chemical plant boilers is what works what chemical plant boiler is? Energy conversion device is a boiler, a boiler input energy comprises a chemical energy, electrical energy, thermal energy of the flue gas temperature and the like. After conversion of the boiler, steam, water or high-temperature organic heat carrier having a certain thermal energy to the boiler outlet. Mainly used in thermal power plants, ships, locomotives, industrial and mining enterprises. The main principle is a use of the chemical energy released by combustion of boiler fuel or industrial waste heat transferred to the water container, the water reaches the desired temperature or pressure of the steam heating apparatus. Boilers and boiler furnace two parts at the same time, water enters the boiler, the boiler heating surface in the steam - water system will absorb heat transferred to the water, so that by the hot water reaches a certain temperature and pressure to produce hot water or steam or, is introduced into the application. cation. In the combustion apparatus part, sustained release heat of fuel combustion, high temperature flue gas produced by combustion heat propagation, to transfer heat to the boiler heating surface, the temperature itself is gradually reduced and finally discharged through a chimney. Works chemical plant boilers is what - Classification brand wns type steam boiler industrial: First, the fuel can be divided into: 1, coal-fired boilers, 2, oil-fired boiler, 3, gas boiler, 4 electric boiler, boiler and nuclear 5, 6, waste heat boiler, etc., most top four, the most common, the lowest operating costs of coal-fired boilers, but a large area, serious environmental pollution, the requirements of operators, gas boilers high degree of automation, operating costs than coal, accounting small land area, requiring fewer operators, I did not use electric boiler, but running costs should be the highest, but the small boiler footprint, environmental protection is the best, the other boiler is not introduced, because I do not understand you the meaning of. two. The heat transfer mode can be divided into water-tube boilers, the thermocouple tube boiler, water tube boilers and fire tube boiler. Usually gas fuel boiler fire tube boiler, typical Type: series WNS (horizontal combustion boiler combustion chamber), this boiler characteristics: simple structure, the rated capacity of the evaporator is generally small (typically 10 tons or less, have a greater , but generally not more than 35 tonnes), starting the furnace pressure faster, lower quality requirements boiler; coal-fired boilers typically water boiler. Tube boiler, water tube boiler high thermal efficiency, but the complex structure of the boiler a higher quality requirements.

As one of Beijing's air pollution emission standards of the most demanding urban, environmental control is very strict. Beijing primary school campus Emerald City as one of the cradles of socialist culture successor, in terms of the quality of students' learning environment is put emphasis on one hundred percent. October 2017, Beijing primary school campus Emerald City with my company, signed a two Thalia T6 series vacuum hot water boiler for winter heating use.

Gas brand wns type steam boiler industrial loading, installation considerations gas steam boiler is a very wide range of special equipment, usually built in the boiler room. However, its load, the installation process, some issues must be taken, otherwise it may cause a certain degree of economic losses. 1, the process of handling and transporting gas in a steam boiler to be noted the following: the lifting capacity of the lifting device should be matched to the weight of the boiler Lifting. Can not be used for lifting has a length marked with a lifting lug can not be used should be chosen on the boiler rope, rope length to avoid inappropriate, leading to scratching furnace. In the loading, unloading and handling process must ensure that the boiler without any damage. 2, installation of boiler maintenance reserve space, make sure there is enough space for maintenance around the boiler. 3, the base gas steam boiler, the base of the boiler and precautions to be installed on the basis of 100-150mm above the floor of the boiler on the premises, subject to prior confirmation boiler manufacturing company with technical personnel, in accordance with the basis for construction drawings. Must stay out of anchor bolts embedded hole basis. Foundation must be able to withstand the weight of the boiler and the largest holding water amount. When the mounting base, must first be positioned. After the alignment adjustment in the end the length of two diagonal lines of the same base, then the entire tightening the fixing bolt. Base mounting reference line marked for reference. 4. General Precautions Be careful not to tilt too boilers and accessories and be impact. Can not be placed outside the boiler fuel. Do not dirty oil and water boilers should generally be installed in a separate boiler room, the new gas steam boiler room should not be connected to the house. A boiler can not be connected, (B) and (C) use of flammable liquid fire risk room. If the production plant is connected to the other, separated by a firewall application. 5, fire resistance rating of the boiler room of the building and fire safety requirements should be consistent with "architectural design code for fire protection" and "design of tall buildings for fire protection" requirements. Gas-fired steam boiler room on the ground should be smooth, non-flammable, no water, load-bearing foundation should meet the requirements. Gas-fired steam boiler supply voltage should be stable, to avoid burn electrical components. The voltage instability, is recommended to install regulators. To set the boiler room ventilation equipment, to maintain the boiler temperature at 50 ° or less.

Select brand wns type steam boiler industrial fuel gas of good or good? Steam boiler has a lot of varieties, the most common classification is based on it can be divided into fuel to burn natural gas and electricity and fuel burn of. When buying a steam boiler, a lot of people do not know that we should buy natural gas or fuel steam boiler steam boiler. Gas boilers and oil boilers are our two most common ways the boiler. If you want to use natural gas steam boiler, the need to ensure that there are local gas can be switched on; if you want to use oil-fired boiler, the procurement needs daily oil tank and oil tank buried, placed in position and good design, so that the fuel supply to the boiler. Gas-fired boiler burning natural gas, it has the primary energy saving, high thermal efficiency strengths, oil-fired boiler burning diesel fuel is light, it has a simple fuel reserves by the fuel supplier strengths affect small. The primary operating costs and fuel gas steam boiler steam boiler related with local energy pricing. Per ton of steam vapor is about to use the side 80, if the offer by gas 3 yuan / square to count, that is, 240 / ton operating costs. Steam per ton of about 66kg of light diesel oil is used, if the press 9 yuan / kg fuel offer calculated, then the cost of steam is about 594 yuan / ton. To compare quotes from the fuel, then, natural gas will be cheaper than oil.