Commercial 6 ton Natural Gas boiler Distributor Brunei

Comfortable life of people is inseparable from the northern winter heating commercial 6 ton boiler distributor brunei, normal, stable heat source is vital to people's lives. But the attendant is an increasingly serious environmental pollution problems, the implementation of coal to gas policy without delay, using the gas hot water boiler is the general trend. In order to achieve green heating, the National Tourism Administration Service Center decided to phase out the existing coal-fired boilers, the introduction of clean and environmentally friendly gas hot water boiler. Fast boiler with their own strong comprehensive strength and rich experience in the heating industry cooperation gained the trust of the National Tourism Administration Service Center, and ultimately provide a vacuum hot water boiler (T6-2800 2 sets of 2.8MW by fast Boiler ).

Fuel gas control step and the blowing process air volume of the total fuel gas steam commercial 6 ton boiler distributor brunei steam boiler is achieved by adjusting a liquid coupling scoop blower. Organization fuel gas steam boiler combustion, is to make a, air pressure, air flow of secondary air with the good. Adjusting the amount of primary air should meet it carries the fuel into the furnace ignition of volatile oxygen required, and to maintain a certain speed, and without clogging the fuel discharge pipe of the jet having a certain rigidity. Primary air volume is too large and too small, the wind speed is too high and too low, should be avoided. In addition to adjusting the secondary air of combustion of the fuel should ensure that the oxygen demand, but must maintain a certain wind speed and primary air is mixed with the master time should have a strong stirring and mixing coke penetrate "the Gray" kinetic , which requires the case may be, each layer of the secondary air flow rate, in order to achieve stable combustion and flue gas excess oxygen appropriate destination. Fuel gas steam boiler, secondary air with what is better? Primary air volume air volume of the total share is called the primary air rate. A small air fraction, pulverized coal is heated to at least the heat required for the ignition point, fire faster, but the amount of primary air to satisfy the principle of combustion of volatiles. Secondary air mixed with the primary air time to the right. If it is mixed before ignition, means an increase in the amount of primary air, so that the ignition delay; hypoxia combustion secondary air if mixed will make late after ignition; if secondary air is mixed all at one position, since the secondary air temperature well below flame temperature, the flame temperature decreases, the combustion slows down, causing the fire. Therefore, the secondary air mixed with fuel should be based on the nature of the combustion zone as required timely sent, so that the combustion of oxygen, and will not reduce the flame temperature to ensure complete combustion and ignition stability. One or two wind speed with what is better? Fuel gas steam boiler once the wind speed is high, the fuel gas stream will catch fire in places far away from the burner, the ignition point postponed; once the wind speed is too low, it will cause a blocked ducts, and ignition point is too far forward, the burner will burn , but also easy to coke near the burner.

Gas oil-fired commercial 6 ton boiler distributor brunei room ventilation system designed along with economic development, energy supply and demand changes in the relationship between environmental protection requirements increase, electricity and oil and natural gas in recent years, increasingly used gas oil-fired boiler. The gas oil-fired boiler room design related to people's life and property security of the country, but also can ensure the normal operation of critical boiler. In addition to the location of the boiler room and capacity to meet the relevant specifications, the design of the ventilation system which is also an important element in the design of the boiler room. However, due to the content of conventional ventilation and manual specification relates to small, there is no specific calculation method is given, designed to bring some difficulties. In this paper, problems in this area, combined with engineering experience of the author, make some analysis, calculation and discussion, put forward their views, for your reference. 1. Design Principles gas fuel boiler room ventilation system

6 ton industrial wood fired steam commercial 6 ton boiler distributor brunei features:

1. Furnace and the two sides of burner zone adopts membrane water-cooled furnace structure. The membrane structure of wood fired steam boiler, our company’s solely design once used in electric boiler , is now applied in shaped assemble boiler. Its advantages lie in great thermal transmission heat, better heat transfer effect, lower heat loss ,better air impermeability, no wall distortion and no ash leakage.

2. The structure of arches adopts the newest technology --the upside”a” technology, which is awarded the national science and technology prize. The front arch is high and short while the back arch is low and long. And the part near the exit is inverse inclined type,while the front arch is 45ºinclined type, they together form a downside a flame structure,which makes the lean coal combustion easier and it can adjust itself to a wide rang of coal types. In this way, the flue gas is kept within the furnace a longer time, and the combustion efficiency is higher. The streamline shaped back arch can throw the non-burned carbon grains in the middle and back part of furnace to the front, so that the coal can be easier to be ignited and the ignition lines are tide.

3. The wood fired steam boiler adopts double layers or single layer layout structure, which can meet the customers’ requirements better.