4t Natural Gas hot water boiler Cheap Indonesia

Henan run several areas, including Henan gas boiler gas boiler operation includes several aspects: daily monitoring and adjustment operations; accident treatment; start and stop; optimal operation mode and technology improvements. When the normal operation of the boiler, the daily operation of the monitoring and adjustment of the operating accounts for the major part. "Stable" is the key, pressure, temperature, water level, negative pressure, milling parameters, etc., remain stable conditions is an important guarantee for safe and economic operation. Briefly, the steady working primarily by "balancing" the means to obtain, for example, outside the furnace combustion conditions and load balance, the pressure is stable; to balance the amount of water and evaporation, is stable water level; primer with the supply air volume the amount of negative pressure equilibrium is stable, according to Henan gas boiler operation adjustment purposes, and in accordance with the purpose of regulating the boiler operation, to take the necessary means of regulation. Daily adjustment of the key - "steam pressure." Among the major parameters of Henan gas boiler, main steam pressure to maintain stability is the key which only the steam pressure is stable, the remaining parameters to stabilize. Unstable steam pressure, steam temperature, the water level will also change, so first of all start from the pressure adjustment. Vapor pressure is divided into an outer and an inner interference disturbance, our plant, i.e. outside the external disturbance load generally little change, so change in vapor pressure are changed within the furnace i.e. interference caused by operating conditions, so holding furnace combustion conditions the stability is the stability of the vapor pressure. If the combustion conditions change, such as wind than powder, coal calorific value and other factors change, a pressure change occurs, requires us to be adjusted, thereby changing into a stable state of the combustion furnace transient state conditions.

Biomass 4t hot water boiler cheap indonesia for heating company fueled with the biomass grain fuel,which is abandoned as agricultural straw waste instead of the fossil fuel.this fuel is easy to get and extensive sources, the fuel costs are lower than the original coal, oil and gas, which is a great way to reduce investment cost for biomass boiler used enterprises.

The characteristics of the fuel gas steam boiler: 1, burner gas steam boiler is supplied by well-known manufacturers in the world, burn automatically stop controller in accordance with instructions, a separate control box has a number of security, safety and stable performance, low maintenance. 2, advanced automatic steam boiler controller, Chinese LCD screen, the man-machine interface, the user simply easily set, i.e., according to user requirements boiler start and stop, load adjustment, automatic water supply, such as automatic operation. Boiler fully functional, complete protection, easy to operate, safe, reliable, self-diagnostic function. Boiler operation anomalies automatically interrupt burning, audible alarm once appeared. 3, the steam boiler burner mode is set, double return configuration, fuel combustion, boiler stable; inserted spoiler smoke tube, smoke slow speed, increase heat transfer, a high thermal efficiency, and reduce cost. Gas fuel oil boiler 4, horizontal steam boiler shell type three return all wet back downstream pyrotechnic pipe structure, i.e. increase the strength of the heat absorption of the boiler, but also to meet the needs of thermal expansion of the heating surface, scientific and rational, prolonged durable. 5, in strict accordance with the present boiler "Steam Boiler Safety Supervision", JB / T10094-2002 "industrial boilers general technical conditions", JB / T1619-2002 "boiler manufacturing technology conditions potshell" requirements, design, manufacture, monitoring inspection to ensure good quality of boilers, achieve low energy consumption, high thermal efficiency, stable pressure, gas and quantity, economic use. 6, a large boiler furnace space, storage, steam and more adaptable load capacity. Rational design of steam separator apparatus built to meet user requirements need to use higher quality steam. Furnace open manhole, head holes, hand holes, to facilitate the internal furnace to clean up, make repairs, maintenance is very convenient. 7, is provided with a multi-stage boiler safety interlock protection: Pressure switch protection (higher than the set auto stop and pressure), low water protection (boiler water level is below the body of the warning level, the alarm and automatically cut off power), the protection valve (boiler pressure exceeds the pressure of work, discouraged automatic blood pressure) to ensure foolproof boiler in a variety of conditions, safe home. 8, the combined organic appearance of mechatronic, sophisticated new, compact, less space, easy to transport and install. 9, using the new material and the thermal insulation quality white color plate package, lighter in weight, good insulation properties, beautiful, not rust.

Shandong Mining Group in the six months after the boiler use, users submit a report to our company, our company started in 2017 using WDR0.5-0.8-Ⅱ electric fast Boiler Co., Ltd. of heating steam boiler. Large output, stable and reliable, high degree of automation, simple operation, do especially in terms of security is in place. After-sales service is very timely response to our technical consulting reply quickly and accurately. Whether it is party party products or fast fast service. My company is very satisfied. --customer feedback