Manufacturing Companies Industrial 2t oil fired boiler Cambodia

3. 1-20 ton wns series oil/gas manufacturing companies industrial 2t fired boiler cambodias

The compact wns series oil/gas boiler is available from 1 to 20 tph. The wns series products is a three-pass boiler with low combustion chamber loading. It delivers clean combustion with particularly low nitrogen oxide emissions. The three-pass design reduces the dwell time of the hot gases in the high reaction temperature range. This results in reduced nitrogen oxide emissions.

To conscientiously implement the CPC Central Committee and State Council "on the overall strengthening of environmental protection and resolutely fight pollution prevention advice tough fight" and "the State Council on the issuance of three-year winning the Battle of the blue sky plan of action," the spirit, manufacturing companies industrial 2t fired boiler cambodia emissions control, prevention and treatment air pollution, the State environmental Protection Department to develop "boiler air pollutant emission standards." In order to further the implementation of air pollution control operations, all regions at the same time meet the national standard, but also have introduced a more stringent local standards.

From the implementation of the Beijing gas nitrogen oxide emission standards for boilers began 30mg, emissions from gas-fired boiler has been of great concern, expand around the "coal to gas" action, so that gas such devices become the most countries to promote clean energy boiler.

The transformation of the current common low nitrogen boiler, there are three main measures: (1) replacement of boilers, (2) replace the burner (3) in the boiler flue gas treatment.

Controlling the nitrogen oxide generated from the source, the most advanced technology on the market today is the use of flue gas recirculation techniques and FGR premix combustion gas boiler technology, both having different focus, low nitrogen emissions boiler.

Replace the boiler burner, renovation and debugging, and the impact on the safety performance of the resulting boiler, burner unit by the responsible manufacturer or his authorized. Beijing Bureau of Quality and Technical Supervision, Beijing Municipal Environmental Protection Bureau issued the "Notice on the transformation of the low - NOx combustion safety risk warning" states: the transformation of low-nitrogen combustion boiler diverse, complex technology, to protect the smooth implementation of the work of reform, effective prevent security risks, prevent accidents, analysis and appraisal by experts, it is not recommended comprehensive safety, environmental factors, the following recommendations:

Nitrogen oxides have been generated by some means and then reduced to nitrogen, the main fuel reburning, selective catalytic reduction, selective non-catalytic reduction. But in the actual monitoring, the nitrogen oxide emissions controllability is poor.

The transformation of low nitrogen gas boiler is a need for long-term adherence and actively manage the work, under the premise to meet the national standards, do specifically address the specific circumstances, not blindly, careless handling, to adopt plans, goals, ideas implementation, to achieve a comprehensive upgrade gas boiler.

Combustion Adjustment of dual-use oil and gas manufacturing companies industrial 2t fired boiler cambodias (Skills) boiler firing was successful, the load can be adjusted to normal operation. At this point, we should always observe the furnace combustion, if there is a bad oil and gas atomization, beating the flame, the flame hit the furnace and the exhaust gas temperature is too high or too low and so, it is timely for oil pressure, oil temperature, of steam, wind, air pressure, steam pressure hanging line adjustments to ensure safe and economic operation of the boiler. Size and load size of hydraulic, pneumatic boiler related to the oil pressure adjusted by adjusting the back pressure or fuel burner to achieve the size, by adjusting the air pressure to achieve the degree of opening of the valve. Adjust the amount of oil, air pressure adjustment load, at the same time, air volume control, must be synchronized to ensure a reasonable match of oil and the amount of wind, so as to achieve economic operation of the boiler. 1, the combustion method of determining boiler fuel gas: C02 content is determined from the flue gases and excess air ratio (1) the combustion quality (2) determines the length of the flame from the combustion quality (3) from the flame color and smoke color determination 2 is good or bad combustion, fuel combustion boiler adjustment method: the normal combustion, furnace flame stability was white orange, generally rumble, or if the flame beating abnormal sound, should adjust the fuel and air volume. If the adjusted still no improvement, it should identify the cause flameout, the measures to be taken and re-ignition.

Select oil or gas manufacturing companies industrial 2t fired boiler cambodia, it can not simply decide based on how much the cost, and comprehensive use of their own units comprehensive selection. First need for oil-fired boilers and gas boilers have a clear understanding, and then decide what boiler according to the needs and environmental conditions of their own units, do not listen to other people a few words hastily make a decision.