Fully Automatic Energy Saving Natural Gas boiler Maldives

Method for safe operation of steam fully automatic energy saving boiler maldivess steam boiler before use, must be checked for damage of the insulating layer, to check the burner is operating correctly, and to check the position of the opening degree of the valve to ensure it is correct. Must be checked for automatic control instruments and equipment safety equipment accessories, equipment, in order to comply with the requirements. Check item prior to ignition of the steam boiler: open valve before oil circulation pump, oil heating valve is opened, adjusted reasonably high level of the tank, the gas pressure is determined before the natural gas burner ignition must be within the range, the power good . Refers to the operation of the steam boiler is refluxed pressure activated device circulating pump, the circulating pump outlet, inlet, outlet, and the system, it is in the normal range. Circulation pump run for 30 minutes. After the stability of the system, the next step. Open the gas tube steam boiler manual valve, button start-up burner, natural gas burner into the furnace, and then the ignition, the flame remains stable, i.e. is in a safe operating condition. In the firing process steam boiler, if you accidentally quenching phenomenon occurs, the device will automatically interlock burner saver appear. It must be promptly cut off the natural gas pipeline to start the furnace purification. Replacement of the residual gas in the furnace and closed. The system load requirements, temperature requirements and thermal oil outlet, the burner can automatically adjust the size of the fire source.

The Secretary-General Wang Group to a variety of innovative measures gave high praise, the use of multimedia technology exhibition virtual and digital technology to explain the esoteric fully automatic energy saving boiler maldives technology, not only new forms but also improve viewing and exploration interest, indeed boiler technology showcase of a major undertaking; clean fuel test Center is the real installation run a variety of products, set energy efficiency testing, the burner test, strengthen research experiment of heat transfer, centralized control system as a whole, provide a true and reliable test data support for a variety of indicators, to promote gas-fired boiler development of the industry plays an important role.

Multi fuel design CFB fully automatic energy saving boiler maldives Challenge

Multi-fuel CFB boilers typically burn a mixture of waste or alternate fuels along with natural gas, fuel oil,or pulverized coal.This provides an opportunity to produce steam at lower cost than a basic fossil fuel fired unit, but it also makes operations more challenging.Waste and alternate fuels vary in Btu content per volume and their supply is often not consistent. This significantly affects combustion stability and the ability to reliably meet load. More expensive fossil fuels must be used when waste and alternate fuel is not available or to make up for low Btu. Managing this without excessive cost is difficult.In addition, operating within emissions constraints may be a problem with multiple fuel streams in the mix.

Method of reducing the exhaust gas temperature of the fully automatic energy saving boiler maldives which: standard boiler exhaust gas temperature: between the boiler flue gas temperature of 200-230 deg.] C in accordance with conventional design national standard thermodynamic calculation boiler design requirements. Conventional exhaust gas temperature selected reasons, coal fired boiler combustion process will produce a certain amount of SO2, and SO2 below 170 ℃ will bind and generating flue gas H2O H2SO4 sulfuric acid, H2SO4 sulfuric acid and will form boiler heating surface of tail corrosion, thereby reducing the life of the boiler, conventional coal-fired boiler exhaust gas temperature is higher than 200 ℃. Temperature is high energy loss and more, is not conducive to energy saving. Cooling measures taken to ①, the economizer application: increasing the boiler economizer (economizer) of heat transfer area, larger than the conventional take about 1-2 times the flow cross sectional area economizer structure, effectively reduce smoke flow rate, to strengthen the heat transfer efficiency, reduce exhaust gas temperature; ②, air preheater applications: pipes connected to the air preheater economizer disposed, the apparatus can effectively increase the temperature of the combustion air, improving the ignition of the fuel condition. Very beneficial to the boiler combustion conditions. ③, adjust bidirectionality combustion system, a boiler originally designed for fuel specifications have some flexibility, different media in effect outside the combustion process are different, adjusting the embodiment, with the economizer and the air preheater using, the temperature of the boiler exhaust emission control at a suitable temperature, that make full use of heat energy, but also to ensure the integrity of the structure and function of the relative equipment, environmental protection, energy saving, security and development is the social responsibility of all of us for a rational design of industrial structure boiler, thermal efficiency is relatively high, its emissions would be relatively low temperatures, so we must be careful when choosing a boiler boiler property report form.