Water wall boiler tube leak or burst phenomenon how to do 1, the normal water flow is not greater than the steam flow. 2, the furnace pressure transient and unstable prejudiced. 3, tube leak detection alarm device. 4, the furnace may not tight at the outward discharge gas and water vapor, and a significant leakage sound. 5, the main steam pressure drop. 6, boiler combustion dark flame instability caused by severe boiler fire. 7, when the induced draft fan is automatically cast, abnormal static vane opening is increased, the current increases. 1 reason, the presence of water wall tube material defects or post-production, the installation of the damaged pipe, poor welding quality. 2, the inner tube fouling overtemperature. 3, the inner tube corrosion. 4, water wall wear. 5, the long-term high load operation, furnace coking, coal sulfur corrosion caused by high temperature water wall. 6, improper combustion, flame deflection. 7, in the possession of bad foreign body, the water cycle. 8, the wall of the long-term over-temperature operation. 9, the temperature difference between waterwall tubes, mechanical stress crack. 10, the normal exit or drain sootblower steam punctured tube. 11, smashed chunks of coke furnace water wall tube or serious explosion occurred, resulting in water wall tube suffered external damage. 12, boiler overpressure long run. 13, the boiler starts to heat up, step-up too fast. 1 process, the leakage should try waterwall tubes outage. The leakage is not serious, while still capable of maintaining operation, note that each of the automatic operation when the device, if not normal, it is cut immediately to the manual, if necessary, may be down, down-load operation. Closely monitor the development trend of damaged parts, good accident anticipation, application shutdown as soon as possible. 2, if the leak is serious, the bursting point temperature after a sharp rise in quality work, leading to serious over-temperature wall, unable to maintain the normal operation of the boiler or threaten the safety equipment, emergency shutdown provision should be processed, when the steam temperature to protect the action value, the protection does not move, should immediately hand MFT. 3, note that the operation of the electrostatic precipitator, to strengthen the inspection checks, to prevent fouling, and the electrodes ESP hopper, pipes and the like plugging air preheater ash. 4, after the shutdown, should retain ID fan, the furnace pressure is maintained constant, there is no discharge to be stopped after soda ID fan.

Since the Shanxi provincial government issued "on the issuance of the People's Government of Shanxi Province, Shanxi Province to win the Battle of Blue Sky's three-year action plan", cities are actively responding to priorities and deployment. Jiexiu municipal government related departments have carried out remediation phase out coal-fired boilers.

Future, Jiexiu City departments should fully understand the situation of air pollution prevention and control of the seriousness and urgency of initiatives to further strengthen the work, work harder to accelerate the phase-out of coal-fired boilers; comprehensive investigation to the use of coal-fired boilers, find out coal-fired boiler unit, boiler type and capacity, device status, etc. and establish a sound accounting boiler, cleaning up coal-fired boiler plant are out of range, so that base clear, the situation is clear, should be eliminated to make sure that eliminated; to clear objectives and tasks , responsible units, measures, in accordance with the time node in an orderly way, and effectively perform their duties, earnestly implement the clean alternative heat sources, the removal of coal-fired boiler with a new energy escorts to carry out work at the same time; to actively coordinate electricity, gas sector, as coal-fired boiler users to implement clean energy transformation provides safeguards to ensure that coal-fired boilers out of the objectives and tasks completed on schedule, and improve urban air quality, and gradually improve the quality of life of the masses.

A steam boiler is an industrial boiler that heats water to a certain parameter and generates high-temperature steam. Water is heated into steam in the drum, and the furnace gives out heat, which is the principle of a steam boiler. Steam boiler belongs to special equipment. Boiler design, processing, manufacture, installation and use must be supervised by the technical supervision department. The user can only use the steam boiler by obtaining a certificate of use of the boiler. According to fuel (electricity, oil, gas), steam boiler can be divided into three types: electric steam boiler, fuel steam boiler and gas steam boiler. According to the structure, vertical steam boiler and horizontal steam boiler can be divided into small and medium steam boilers. Double-return vertical structure and large-scale steam boiler are mostly three-cycle horizontal structure. Steam boiler scale inhibitor is a composite product composed of organic phosphonic acid and polycarboxylic acid, which has high corrosion inhibition and scale inhibition. After washing the gas steam boiler, the water distribution tank becomes the water wall bottom box and the temperature resistance is very good, which can be effectively applied to the water treatment of the low pressure boiler. Gas-fired steam boilers are suitable for corrosion and scale inhibitors, as well as for seawater desalination, distillation and automobile water tanks. The use of scale inhibitors in steam boilers can effectively suppress copper tubes and carbon steel composite components in the process; anti-F E3, Cu 2 accelerates corrosion resistance. The scale inhibitor used in gas-fired steam boiler is the guarantee of the safety of the equipment, it can be easily removed completely and at the same time reduce, the operation is simple, safe and reliable. The scale inhibitor used in gas-fired steam boiler is simple, can be discharged after neutralization, safe and environmentally friendly. It can reduce the use of scale inhibitors to maintain the performance of gas-fired steam boilers, which is conducive to the direct use of users and regular cleaning and maintenance of gas-fired steam boilers, saving equipment maintenance costs. According to the specific operation conditions of gas-fired steam boiler, descaling is simplified and easy to install and operate.

To introduce steam boiler pressure gauge and hydraulic press accumulator using steam boiler pressure gauge should pay attention to: 1, rated steam pressure is less than 2.45MPa steam boiler, the accuracy of pressure gauge must not be 2. 5; Rated steam pressure large or equal to 2.45MPa boiler, pressure must not be less than 1. 5 class. The diameter of the dial of the pressure gauge shall not be less than 100 mm to ensure that the operator can see clearly the surface pressure indicator value. 2. A red line should be drawn on the pressure dial of the steam boiler pressure gauge, indicating the maximum allowable working pressure. Steam boiler pressure gauges should be installed in a place that is easy to observe and wash. 4. Steam boiler pressure gauges should be checked at least once every six months, and should be sealed with lead after calibration. 5. Steam boiler pressure gauges should not have leakage of water and steam leakage in the connecting tubes of the pressure gauges of steam boilers. (4) the steam boiler pressure gauges should be checked at least once every six months and sealed with lead. 5. Otherwise, the pressure indicator value will be reduced. 6. The measurement range of the steam boiler pressure gauge should be adapted to the working pressure of the measured components, usually 1.5 times of the working pressure, preferably 2 times of the working pressure. Steam boiler does not have pressure gauge, the pressure gauge is damaged or the installation of pressure gauge does not meet the requirements, steam boiler pressure gauge should be stopped when one of the following conditions: 1, broken surface glass or dial calibration mold There is no clear paste; 2, no lead seal, lead seal damage or beyond the calibration period; 3, without pressure, the pressure gauge of the finite pin can not be restored to the limit pin, the infinite position of the gauge pointer deviated from zero data beyond the allowable pressure clothing; 4, gas leakage or pointer jump in the meter; 5, other defects that affect the accuracy of the gauge. Purpose of the accumulator: the accumulator is used in the hydraulic system of intermittent machinery, which stores the oil output of the hydraulic pump during intermittent or low-speed movement of the actuator, and when the rapid movement of the actuator requires a large flow rate, As an auxiliary energy source, together with the hydraulic pump, the oil pump is supplied to the system, thus the oil pump and the hydraulic pump are realized. The miniaturization of the whole hydraulic device absorbs the quick opening and closing of the impact hydraulic reversing valve and the sudden change of the load. The system will produce shock pressure, the darling will lead to vibration and noise, and even damage the machine. The accumulator can mitigate the impact pressure absorption pulsation of these fluids absorb and reduce the flow pulsation and pressure pulsation of various hydraulic pumps thus reducing the system noise and vibration. The damped accumulator acts as a gas spring and can be used to absorb the vibration between the fuselage and wheels of walking machinery such as vehicles. The balanced accumulator absorbs the gravitational potential energy of the vertical actuator (hydraulic cylinder) and its load as it falls. When the vertical actuator rises, the accumulator releases the original absorbed energy and supplies oil to the hydraulic cylinder together with the pump, thus realizing the balance and energy saving.