modular gas steam boilers

3 ton oil gas boiler for concrete mixing plant

The product of this project is the CBM wns series oil and gas steam boiler with a boiler capacity of 3 tons. The boiler is used in a building material factory in Russia to provide steam for concrete production.

More details gas boilers should be promptly after use as a modular steam boilers plant drainage, heating, bath with gas boiler is a kind of fuel for the gas equipment (fuel gas-fired boilers), because it is compared with oil-fired boiler, electric boiler up more economical, which is widely used. After carrying out the gas boiler must turn on the water to be disabled. Why is that? We will come and detailed discussion about this issue today. To turn on the water when the gas boiler is disabled: gas boiler in the boiler water if the winter will put the cracking, there will be odor and summer long embroidered, so that the life of the boiler will be reduced. At the bottom of the boiler there is a turn on the water with the section of the door, then opened, gas boiler pipes in the water will flow back to the boiler, the boiler is done and the water on it. Water level controller SZB-IV (electrode type water level alarm) 1. When the normal level of + 30mm, pump control switch contacts are open, the pump stops working. 2. When the normal water level -30mm, pump control switch contacts in contact, the pump starts to work. 3. When the normal water level of + 50mm, a first group of electromagnets high gas boiler water level contacts the combined output high level alarm signal. 4. When the normal water level of the gas boiler -50mm, a second group of electromagnets in conjunction with the low water contact output low water level alarm signal.

Strict accordance with the operation of the gas modular steam boilers feed water softening process is provided gas steam boiler fouling not only reduces the thermal efficiency of the boiler, but also increases the temperature of the boiler heating surface, damage to the heating surface, even causing the boiler explosion. Thus, soft water treatment equipment, strict accordance with the operation of the boiler feed water softening processing apparatus, the control of boiler feed water quality, delay the formation of scale. At the same time, real-time control the size of the boiler, boiler scale control, cleaning the scale, if necessary, it is very important. Since the gas steam boiler and vapor - water heat temperature is higher than the temperature of the air system of the boiler room, part of heat to the surrounding air by radiation and convection, which became the heat loss. boiler. Accordingly, when the insulating layer and the heat pipe of the boiler system damage or leak is detected, it should be repaired, to reduce heat losses. Steam boiler burner gas noise increases, mainly because of lack of or close the valve in the oil passage into the oil, oil filter plugging; or into the oil due to the low temperature viscosity is too high or oil pump. Temperature is too high; oil pump failure; fan motor bearing damage; dirty because the turbine wheel, the device too loud. When said failure when using gas boiler, and since the viscosity of the oil is too high, atomization is not easy (heavy oil); and because the distance between the nozzle and the cyclone unsuitable; In addition, since the burner worn or dirty; also because reserve tank temperature is too high, leading to the oil pump steam; oil boiler or because the oil is hydrated. Gas steam boiler feed water containing various impurities and calcium and magnesium scale substances, boilers inevitably expanded. Very low thermal conductivity of the scale, once contaminated surface is the surface heat, the exhaust gas temperature of the boiler will increase, and due to the increase in thermal resistance, heat loss of the exhaust gas will increase. Experimental data show, 1mm scale formation in boiler heating surface, the heat loss of the exhaust gas will increase from about 2-4%. Scale thicker boiler heating surface, the greater the resistance, the lower the thermal efficiency of the boiler.

Beginning of winter is over, the whole city of Tianjin into the heating season. To protect the normal operation of the boiler for heating, Market Authority Wuqing District of heating boilers launched special safety checks to ensure that the boiler use foolproof.

District Supervisor Bureau in-depth understanding of Xintai heating station, heating station and peace in the State Central heating stations, boilers whether to register for the use of the boiler and its safety accessories, combustible gas alarm is within the test period, fireman job Are personnel certificates, if the boiler water through a rigorous inspection process and other aspects. Check the site also records the boiler operation, safety management systems, development and implementation of contingency plans to view, focus your heating boilers meets the requirements of the region's policy "ban on coal zone".

Next, Wuqing District will continue to monitor the safety inspection of heating boilers used as a focus for specific problems, increase the inspection frequency and law enforcement, to protect the safe operation of heating boilers Wuqing District.

Market Authority has in-depth Xintai district heating stations, heating stations and peace in the State Central heating station, focus on checking whether the boiler for the use of registration, boiler and safety accessories, combustible gas alarm is within the test period, fireman whether the worker certificates, if the boiler water after treatment. They also view the site log boiler, the development and implementation of safety management systems, emergency plans, and focus your heating boilers meets the requirements of the region's policy "ban on coal zone". At the same time law enforcement officers required to strictly implement the main responsibility for the safety of special equipment, strengthen emergency duty, special equipment to ensure safe operation. Up to now, law enforcement officers were deployed more than 20 times to check heating boiler unit five times, involving 22 sets of heating boilers, found 10 safety problems, has urged the relevant corrective actions. Next, the council will continue to put safety inspection of heating boilers as a priority, and focus point for the problem, increasing the frequency of inspection and enforcement, to protect the region's heating boiler safe operation.