1 ton oil boiler Low Price Commercial Cambodia

(9)Combustion Adjustment method of Oil-fired Gas-fired Boiler

The combustion adjustment of oil-fired gas-fired boiler is successful and the load adjustment can be carried out after turning into normal operation. At this time, the combustion situation in the furnace should be observed frequently. If the atomization of oil and gas is not good, the flame jumps, the flame hits the furnace tank, and the exhaust temperature is too high or too low, the oil pressure, oil temperature, steam volume, air pressure and steam pressure should be adjusted in time to ensure the safe and economical operation of the boiler. The oil pressure and the pressure are related to the boiler load. The adjustment of the oil pressure is realized by adjusting the pressure of the burner or the amount of oil returned. The adjustment of air pressure is achieved through the opening of the valve. When adjusting a load, enter At the same time, the air volume adjustment must be carried out synchronously to ensure the reasonable match between the oil quantity and the air volume, so as to achieve the purpose of economical operation of the boiler.

June 22, 2018 in the evening around 6:40, Chongqing Hechuan keel village "Ding taste the food factory" 1 ton boiler low price commercial cambodia exploded, the accident killed two people, three people were injured.

At the scene, boiler room Zhata, damaged boiler flew ten meters outside the field, next to a few factories are subject to different degrees of damage, around the ruins. But because not many nearby residents, no adverse impacts to other villagers.

According food factory owner friends when the accident occurred, both inside and outside the boiler room just five people. One person was killed and four people were injured, one of whom died en route to hospital, the other three in stable condition and is currently being treated in. It is understood, Ding taste the food factory is a small tofu factory, usually only a few factory workers. When the accident occurred, it is time off work, the boss's father, Huang uncle went to the boiler room, prepare a little help, but I do not know which part of improper operation, resulting in an explosion.

The boiler explosion, resulting in serious consequences and impact, but also sounded a warning for the steam boiler is using various food processing plants. Steam boiler output to high-temperature steam, with a certain risk, in use, to operate in strict accordance with the provisions, not miss any details, nor allow non-professional staff stoker boiler operation to avoid unnecessary losses.

1, boiler factory should be accompanied by "technical safety specifications of the design documents, product quality certification, safety and the use and maintenance instructions, supervision and inspection certificate (safety supervision and inspection certificate performance)."

2, boiler installation, maintenance, alteration. Engaged in the installation of the boiler, maintenance, renovation of the unit shall obtain special equipment installation and maintenance certificates issued by the Provincial Quality and Technical Supervision, before engaging in the boiler installation, maintenance, alteration. Construction unit before construction will be prepared for installation, maintenance, alteration in writing inform the special equipment safety supervision and management department of the municipality or district, and will start informing sent to the local county level Quality and Technical Supervision for the record, told immediately after construction.

3, inspection of boiler installation, maintenance, transformation. After construction, the construction unit of Special Equipment To Quality and Technical Supervision, Inspection and declared the boiler installation supervisory inspection and hydrostatic testing. After passing by the Quality and Technical Supervision, Special Equipment Inspection, County of Quality and Technical Supervision involved in overall acceptance.

4, registration boiler. After the boiler inspection, the use of units must be in accordance with the "special equipment registration and use of management rules", fill "boiler (census) Registration Form" to the Quality and Technical Supervision registered, and obtain a "safe use of special equipment registration certificate" .

5, operation of the boiler. Boiler operation must be performed by trained and qualified to obtain "special equipment operator certificate" certified personnel to operate, must strictly abide by the rules and eight systems, six record.

6, check the boiler. Periodic inspection of boiler once a year, not be used without safety periodic inspection of boilers. Safety accessories safety valve of the boiler regular inspection once a year, pressure gauge biannually verified, may not be used without the periodic inspection of the safety accessories.

How fuel (gas) 1 ton boiler low price commercial cambodia stack height standards should be implemented as specified?According to requirements "Boiler Air Pollutants Emission Standard" -GB13271-2014 existing files countries, oil, gas boiler chimney of not less than 8 meters, the height of the boiler chimney by specific approval of environmental impact assessment documents OK. When there is a building within a radius of 200m from the new boiler room around the chimney, the chimney should be higher than the tallest building in more than 3m.

The 1 ton boiler low price commercial cambodia is a oil and gas fired boiler and is steam boiler whose steam capacity is 15 tons per hour. And the boiler could burn the fuel such as natural gas, light oil, heavy oil, blast furnace gas.