4t Natural Gas boiler Energy Saving Agent Indonesia

With the increase of air supply volume, the mixture of oil mist and air is improved, which is beneficial to combustion. However, if the air volume is too large, the furnace temperature will be decreased and the incomplete combustion loss will be increased. At the same time, the heat loss of exhaust gas will be increased and the power consumption of the fan will be increased because of the increase of flue gas. If the air volume is insufficient, the combustion will be incomplete, resulting in carbon deposition at the tail, which is prone to secondary combustion accidents. Therefore, each 4t boiler energy saving agent indonesia should pass the thermal efficiency test to determine its economic air volume at different loads. In practice, the stoves usually take into account the ignition of the nozzle and the carbon dioxide or oxygen content in the flue gas. Content to adjust the supply air volume. If it is found that the combustion condition of a nozzle is not good, or if the atomization plate with different aperture is replaced, the air pressure of the supply duct should be kept unchanged, and the opening degree of the duct baffle of the nozzle should be adjusted to normal combustion. If the fuel quantity changes due to the change of the oil pressure in front of the furnace, the opening of the fan baffle should be adjusted to achieve normal combustion by changing the air pressure and air volume of the air supply duct when it is necessary to adjust the supply air volume.

3) the observation and analysis of all kinds of flame when adjusting the fuel oil. Generally through the fire point adjustment and flame center adjustment to complete the flame adjustment. The ignition point of the oil mist should be close to the nozzle, but there should be no tempering. Early ignition is beneficial to complete combustion and stability of oil mist. However, the fire is too early, too close to the nozzle, easy to burn the nozzle and furnace wall to determine the mouth. Furnace temperature flying oil varieties and atomization quality, as well as air volume, wind speed and oil temperature, will affect the distance and proximity of the ignition point. So if you want to adjust the ignition point, you should find out the cause in advance, and then take targeted measures. When the boiler load is constant and the oil pressure and oil temperature are stable, Should be based on the ignition point wind speed and wind distribution situation.

Recently, Tianjin issued a notice to expand the scope of the ban on high-pollution fuel combustion zone, which is based on high-pollution fuel combustion zone ban on the delineation of Tianjin in 2015, to further expand this range, Tianjin has completed the bulk of urban and rural coal clean energy alternative areas have been completed and no did not go to the construction of Wuqing classified as high-pollution fuel combustion zone ban, and to delineate new range of units street town combustion zone ban.

1, the implementation of zoning classification control. Still requires strict control within the range 2015 designated combustion zone ban, prohibited the use of a single steam of less than 35 t / h of coal-fired boiler, steam 35 tons / hr or higher requires a particularly coal-fired boiler for emission limits or ultra-low emission requirements, while a total ban on all kinds of loose coal burning.

2, ban on burning area has expanded. New ban on burning area of ​​3107.99 square kilometers, Binhai New Area and design Dongli, Xiqing, Jinnan, Beichen, Wuqing, Baodi, Ninghe 9 district and Haihe Education Park. After the adjustment, the city's high-pollution fuel combustion zone ban area of ​​830.54 square kilometers by 2015 increased to 3938.53 square kilometers, accounting for 33.05 percent of the city's total area.

3, clearly biomass fuel control requirements. According to local emission standards biomass fired boiler air pollutants Tianjin promulgated in 2018, re-notice provisions of the central city, Binhai New Area, the seat of government of other towns and other key areas of government regulations prohibit burning biomass briquettes .

Check the gas 4t boiler energy saving agent indonesia fuel oil boiler before ignition gas development to today, can be described as advanced technology, but in order to safe fuel gas-fired boiler must be assured, fuel gas-fired boiler before ignition still have to check, and I'll tell below we pre-ignition of fuel gas boiler should pay attention to those aspects: first: fuel gas-fired boiler fuel can be gas, fuel oil if it is, will have to check whether normal pump and filter into the oil; if it is a gas, will have to check the gas pressure is normal , should not be too high or too low. Then open the supply valve of the second oil or gas: a gas oil-fired boiler smoke flue valve, it must look is smooth, not clear if there is a security risk must be excluded. Third: to look at fuel gas-fired boiler control cabinet knob is not in the normal position. Fourth: I have a good job cleaning fuel gas-fired boiler. For our own lives and property in the operation of a gas fired boiler think we must strictly abide by its code of practice for safe operation.

What is the difference between the gas 4t boiler energy saving agent indonesia and coal-fired boiler? Whether gas or coal can be used as fuel for boilers, however, named according to the type of fuel used for different boilers are not the same, so there is such a different type of gas boilers and gas boilers. So both types of boilers in addition to the fuel used in the combustion is not the same, between the coal-fired boilers and gas boilers, what difference does it make? 1, fuel is coal flue gas of coal-fired boilers used in different, when coal combustion will have a greater smoke caused serious pollution to the environment, however, high stability of the gas after combustion boiler did not smoke exhaust, because the basic gas on can be completely burned, toxic black smoke can reach zero ringelman level, SO2 content of which is very small, so there is no pollution to the environment. 2, different heat loss in order to allow coal-fired boilers to maintain sufficient combustion efforts require the use of human or other device to stop adding coal-fired furnace, when the need intermittent operation, it takes a long time to start to increase again furnace temperature, it will generate a lot of heat when the pressure of the fire damage, while the gas boiler is very easy to start and stop, fast heating intermittent operation, thereby reducing heat loss in this process. 3, different treatment after burning coal combustion in the boiler will produce large amounts of ash, in order to maintain a good healthy environment need to transport ash to the professional field slag processing, however, gas-fired boiler using gas , there will be no remaining after combustion ash, there is no need to process it, not only to avoid environmental pollution also reduces the labor intensity and the amount of urban ash storage and transportation companies. This is more than some of the differences between the three coal-fired boilers and gas boilers. By introducing the above we can understand the essential difference between the two boilers can understand, it is because of gas boilers more environmentally friendly energy was gradually replace coal-fired boilers. However, if companies need to use this boiler, in order to advance understanding of the security needs of gas-fired boilers which have quality assurance.